CS Paper Radar

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin

eess.SP ·submitted 2026-09-14 09:57 UTC · v2

Abstract

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

Comment
Submitted to the IEEE conference for potential publication

Closest papers

Nearest neighbours by meaning across the whole index.

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.76
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.60
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.58
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Packet-Level Complex CIR Tracking for Communication-Native mmWave Sensing: An 802.11ad Testbed

eess.SP ·2026-09-14 ·Raquel Marina Noguera Oishi, Haoqiu Xiong, Hany Assasa, Sofie Pollin
similarity 0.57
Abstract

Commercial millimetre-wave (mmWave) Wi-Fi platforms based on IEEE 802.11ad/ay have demonstrated sensing capabilities, but they provide limited visibility into the packet-level measurements and synchronisation mechanisms that determine temporal coherence. We present a programmable 60~GHz IEEE 802.11ad testbed that exposes the complete complex 128-tap channel impulse response (CIR) for every detected packet. This access exposes packet-to-packet delay shifts and common phase drift that commercial-transceiver studies generally do not characterise. We develop a delay-profile alignment method and define a static-reference relative CIR phase that cancels common drift while preserving target-induced variation. We use 30~s respiration sensing to evaluate long-term phase stability for sub-wavelength motion tracking. Across 39 recordings, median absolute waveform correlation increases from 0.41 (timestamp regularised) to 0.52 (delay aligned) and 0.61 (relative-phase calibrated); breathing-rate mean absolute error decreases from 5.1 to 4.1 and 3.6~breaths/min. The results demonstrate controlled characterisation and stabilisation of communication-native WiGig CIR measurements on a fully programmable physical layer.

0.26

CORAL: A Modality Invariant Framework for Robust Vital Sign Rate Estimation Using Correloform Analysis

eess.SP q-bio.QM ·2026-08-15 ·Jacob Trueb, Amey Kasbe, Aniruddh Srinivasan
benchmark similarity 0.56
Abstract · main manuscript: 11 pages, 2 tables, 4 figures supplemental materials: 25 pages, 4 tabes, 31 figures

Heart rate and respiration rate are crucial vital signs. We present CORAL to address challenges in automating continuous vital sign monitoring 1) in-hospital across broader populations (age, disease states), 2) at-home in telehealth and wellbeing applications (noise, placement), and 3) across data modalities (ECG, PPG, SCG, BioZ, etc.). We re-introduce Short-Time Autocorrelation Functions (STACFs) to introduce the correloform - a highly interpretable 2D signal transformation for tracking periodicity over time - and define CORAL as a generic analytical framework for robust rate estimation of quasi-periodic signals. We rigorously benchmark CORAL to show ubiquitous application in biosignals via capabilities arising by mathematical construction rather than domain-specific engineering, including rate estimation, resilient noise handling, automatic channel selection, and signal quality indication. CORAL achieves excellent instantaneous noninvasive fetal HR agreement in FECGSYNDB (F1 = 0.999) and ADFECGDB (F1 = 1.000). With difficult NICU neonates, CORAL estimates RR from wearable BioZ at r = 0.858 against breath-interval RR from simultaneous wired Philips impedance. CORAL SCG HR on CEBS achieves r = 0.990 and in free-living activity r = 0.970 when compared against commercial ECG. Without QRS detection, CORAL's instantaneous HR agrees with Pan-Tompkins and NeuroKit2 detectors as closely as they agree with each other (MIMIC-IV ICU ECG r = 0.87 to each vs. 0.88 between them). CORAL's HR standard deviation correlates strongly with interval-based HRV SDNN, even from mechanical SCG (CEBS r = 0.733) and across an ICU ECG cohort (r = 0.768).

0.10

Human Mobility Sensing Using Wall-Reflected Beamformed Millimeter-Wave Communication Signals

eess.SY ·2026-11-04 ·Tony DiMichele, Raees Matheen Mullah, Christian Lopez Garcia, Zahra Najafi, Mohammed E. Eltayeb
similarity 0.54
Abstract

Existing millimeter-wave (mmWave) communication beam patterns spatially weight human-scattered signals and shape the received-power signatures induced by human motion. We exploit these beam-shaped signatures for device-free walkingpace and walk-direction classification using a wall-reflected 60.8-GHz link with closely spaced phased arrays and fixed communication beamforming vectors. Human movement alters the interference between wall-reflected and scattered signals, producing power oscillations surrounding a central blockage fade. A beam-dependent interference model provides a physical interpretation of these signatures. Using received-power statistics from a continuous-tone experiment, we extract fade duration for walking-pace classification and pre/post-fade asymmetries for walk-direction classification. Measurements comprise 144 crossings from three participants along perpendicular and diagonal trajectories. Under leave-one-participant-out validation, logistic regression achieves 86.1% binary and 79.2% three-class walking pace accuracy, and 77.1% travel-direction accuracy. The results demonstrate mobility sensing using fixed communication beams without channel estimation, Doppler processing, or dedicated radar hardware

0.27

Passive RF Sensing for People Counting with Dense IoT Networks

eess.SP ·2026-10-21 ·Federica Fieramosca, Vittorio Rampa, Michele D'Amico
similarity 0.54
Abstract

Radio Frequency (RF) convergence, the joint use of radio signals for both communication and sensing, is gaining increasing attention in research and industry, mostly for its potential in Internet of Things (IoT) applications. By using RF signals of opportunity, such as those generate by the wireless networks, RF sensing exploits the effects of human bodies on the electromagnetic waves to detect both people presence and their movements without requiring wearable devices. In this paper, we address the problem of estimating the number of people in a monitored area covered by several RF nodes of a wireless network: to this aim, we propose a composite diffraction-based model, namely C-MAM, to capture the cumulative RF attenuation induced by multiple human bodies. Building on this model, we derive the analytical resolvability bounds that quantify the maximum number of distinguishable individuals based on the layout geometry and other physical characteristics of the wireless network. These bounds allow for the pre-deployment assessment of RF sensing performance under different scenarios.

0.27

CardiacMamba: Fair and Robust RGB-RF Fusion for Remote Heart Rate Estimation via State Space Modeling

cs.CV cs.AI ·2026-08-16 ·Bo Zhao, Zheng Wu, Yiping Xie, Zitong YU
similarity 0.53
Abstract

Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions

0.04