CS Paper Radar

CardiacMamba: Fair and Robust RGB-RF Fusion for Remote Heart Rate Estimation via State Space Modeling

Bo Zhao, Zheng Wu, Yiping Xie, Zitong YU

cs.CV cs.AI ·submitted 2026-08-16 16:05 UTC · v1

Abstract

Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions

Closest papers

Nearest neighbours by meaning across the whole index.

Heartian: Physiology-Aware Relightable Gaussian Head Avatar

cs.CV cs.GR ·2026-09-22 ·Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Akşit
publishedbenchmark similarity 0.70
Abstract · 4 pages of manuscript and 2 pages of supplementary material; SIGGRAPH Asia 2026 Technical Communications

Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose Heartian, a physiology-aware modulation framework that learns cardiac-cycle-dependent per-frame albedo modulation of facial skin-region Gaussians within a relightable head avatar to encode remote photoplethysmography (rPPG) signals. Using synchronized contact PPG supervision, Heartian models the prescribed cardiac waveform as the sum of two Gaussian functions and learns per-frame spatial residuals via a lightweight MLP. Across 152 stationary recordings from UBFC-rPPG, PURE, and MMPD, attribute-space recovery of the supplied signal achieves a pooled recording-level heart-rate MAE of 0.29 bpm and MAPE of 0.38%. The signals remain detectable after rendering by benchmark rPPG methods, with the best tested configuration - a motion-augmented TS-CAN decoder pretrained on UBFC-rPPG - recovering heart rate from the rendered MMPD avatars at 0.97 bpm MAE and 1.21% MAPE. Meanwhile, Heartian maintains reconstruction quality comparable to the baseline, with negligible average PSNR degradation of 0.005 dB. Overall, our work embeds recoverable rPPG signals as controllable material attributes to subject-specific Gaussian head avatars while retaining the reconstruction quality.

0.24

Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG

cs.CV ·2026-09-29 ·Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
similarity 0.62
Abstract

Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.

0.21

Property-Specific Recoverability from Contact PPG to Camera rPPG under Heterogeneous Observation Conditions

eess.SP cs.AI ·2026-08-27 ·Timothy Oladunni, Farouk Ganiyu-Adewumi
similarity 0.62
Abstract

Camera-derived remote photoplethysmography (rPPG) is commonly validated through endpoint accuracy, but endpoint performance does not establish whether other physiological properties of source contact photoplethysmography (PPG) remain preserved recording by recording. We evaluated property-specific PPG-to-rPPG recoverability on 655 recordings from the Multi-Domain Mobile Video Physiology Dataset using CHROM as a fixed camera-rPPG observation pathway. The pathway reproduced the published CHROM correlation regime, with heart-rate MAE of 15.26 bpm and Pearson correlation of 0.0801. Matched-versus-shuffled validation revealed modest recording-specific autocorrelation correspondence, while spectral and recurrence-rate measures showed little matched discrimination. Maximal Lyapunov exponents showed essentially no recording-specific PPG-to-rPPG correspondence, with correlation of 0.0231 and permutation p-value of 0.5584, despite population-level overlap. Endpoint discrepancy exhibited Fitzpatrick-associated heterogeneity after adjustment for lighting and motion, including a Fitzpatrick VI versus III contrast of 9.32 bpm, while dynamical discrepancy showed no corresponding gradient. Aggregate RGB signal-to-noise ratio did not materially account for the endpoint contrast. In subject-held-out analysis, adding motion and lighting consistently reduced MAE across linear, ridge, and random-forest learners relative to rPPG-HR-only calibration, with reductions up to 13.32 percent. These findings show that recoverability is property-specific: physiological properties differ in recording-specific preservation and dependence on observation conditions, and population-level plausibility does not establish preservation of individual recordings.

0.27

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

cs.CV ·2026-09-30 ·Bo Zhao, Junzhe Cao, Dan Guo, Dongmin Huang, Wenjin Wang +3 more
similarity 0.57
Abstract

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose \textbf{FLOW (Feature-Level Optimal Warping)}, an \emph{optimal transport--driven} framework for domain-generalized rPPG. FLOW integrates a \textbf{Temporal Refinement Module (TRM)} to stabilize temporal dynamics and a \textbf{Prototype-based Cross-Temporal Optimal Transport (PCOT)} module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.

0.43

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.56
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.55
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.59

Pulse or Provenance? What rPPG-Based Deepfake Detectors Learn

cs.CV cs.CRcs.LG ·2026-11-10 ·Othmane Harraq, Tamer Aldwairi
similarity 0.55
Abstract

Remote photoplethysmography (rPPG) has been proposed as a physiological cue for deepfake detection, based on the premise that synthesized faces lack a genuine cardiac signal. We examine what rPPG-style detectors learn on Celeb-DF++ (22 forgery methods) and FaceForensics++ (FF++), using one identically sampled window per real and fake video. On talking-face forgeries, simple chrominance traces reach an AUC of 0.998, exceeding a dedicated rPPG extractor (0.87). Controlled experiments indicate that this signal is not physiological in origin. On fully synthesized forgeries, it is equally discriminative when extracted from background regions or from full frames without face detection, and it is concentrated above the 0.7 to 4 Hz heart-rate band. It is largely removed by shuffling frame order but persists after normalizing resolution, frame rate and encoding, and an independent reimplementation reproduces these findings. Removing high-frequency content makes most synthesized videos appear real, adding it makes real videos appear fake, and injecting a synthetic pulse has little effect. In controlled self-reenactment experiments with two generators, animating a face from a single frame introduces the same high-frequency signal, whereas reconstructing each frame from its own source does not. Face-based chrominance detectors trained on Celeb-DF++ classify over 99% of real FF++ videos as fake, indicating that they largely encode video source rather than manipulation, and a CLIP-based detector exhibits the same behavior. A frozen CLIP backbone matches or exceeds fusions of CLIP with rPPG and frequency features. Finally, we show that the official Celeb-DF and Celeb-DF++ splits share identities and source-video content between training and test, and that custom protocols reusing test videos and identities in training inflate weaker detectors by up to 0.30 AUC.

0.18

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.54
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25