CS Paper Radar

Heartian: Physiology-Aware Relightable Gaussian Head Avatar

Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Akşit

cs.CV cs.GR ·submitted 2026-09-22 21:25 UTC · v2
publishedbenchmark

Abstract

Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose Heartian, a physiology-aware modulation framework that learns cardiac-cycle-dependent per-frame albedo modulation of facial skin-region Gaussians within a relightable head avatar to encode remote photoplethysmography (rPPG) signals. Using synchronized contact PPG supervision, Heartian models the prescribed cardiac waveform as the sum of two Gaussian functions and learns per-frame spatial residuals via a lightweight MLP. Across 152 stationary recordings from UBFC-rPPG, PURE, and MMPD, attribute-space recovery of the supplied signal achieves a pooled recording-level heart-rate MAE of 0.29 bpm and MAPE of 0.38%. The signals remain detectable after rendering by benchmark rPPG methods, with the best tested configuration - a motion-augmented TS-CAN decoder pretrained on UBFC-rPPG - recovering heart rate from the rendered MMPD avatars at 0.97 bpm MAE and 1.21% MAPE. Meanwhile, Heartian maintains reconstruction quality comparable to the baseline, with negligible average PSNR degradation of 0.005 dB. Overall, our work embeds recoverable rPPG signals as controllable material attributes to subject-specific Gaussian head avatars while retaining the reconstruction quality.

Comment
4 pages of manuscript and 2 pages of supplementary material; SIGGRAPH Asia 2026 Technical Communications
DOI
10.1145/3829339.3847838

Closest papers

Nearest neighbours by meaning across the whole index.

CardiacMamba: Fair and Robust RGB-RF Fusion for Remote Heart Rate Estimation via State Space Modeling

cs.CV cs.AI ·2026-08-16 ·Bo Zhao, Zheng Wu, Yiping Xie, Zitong YU
similarity 0.70
Abstract

Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions

0.04

Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG

cs.CV ·2026-09-29 ·Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
similarity 0.70
Abstract

Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.

0.21

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

cs.CV ·2026-08-30 ·Zixu Li, Jianjun Qian, Hang Shao, Daoheng Li, Lei Luo +1 more
similarity 0.64
Abstract

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.

0.29

EgoHRV: Continuous Heart Rate Variability Estimation from Egocentric Systems for Autonomic Response and Skill Assessment

cs.CV eess.SP ·2026-08-19 ·Berken Utku Demirel, Christian Holz
top venuecode/data similarity 0.63
Abstract · Accepted to the European Conference on Computer Vision (ECCV) 2026

Egocentric vision systems capture human behavior from visible cues, but overlook physiological indicators of autonomic states such as stress, engagement, and attention. Heart rate variability (HRV) is a widely used noninvasive marker of autonomic regulation under stress. HRV reflects small timing differences between successive heartbeats and has so far been out of reach for egocentric platforms, where motion and noise in gaze video mask exactly this fine-grained timing. We propose EgoHRV, a method that estimates HRV as well as heart rate (HR) from the gaze cameras that are already integrated into egocentric headsets. Our pipeline combines a 3D backbone with a novel low--high decomposition module that extracts the blood volume pulse (BVP) signal from gaze video. Our cross-domain pretraining aligns the frequency-domain representations of contact-based and camera-derived signals. This alignment gives EgoHRV the temporal precision to recover HRV from the subtle fluctuations in gaze video. EgoHRV achieves state-of-the-art accuracy for HR and HRV estimation from egocentric video, and its uncertainty-aware design improves downstream behavioral modeling. Integrating our HRV estimates and confidence measures into EgoExo4D's proficiency estimator raises accuracy by 17.8%. Beyond skill, continuous HRV estimation also opens egocentric systems to stress- and arousal-aware estimation tasks. Code: https://github.com/eth-siplab/EgoHRV

0.48

Pulse or Provenance? What rPPG-Based Deepfake Detectors Learn

cs.CV cs.CRcs.LG ·2026-11-10 ·Othmane Harraq, Tamer Aldwairi
similarity 0.63
Abstract

Remote photoplethysmography (rPPG) has been proposed as a physiological cue for deepfake detection, based on the premise that synthesized faces lack a genuine cardiac signal. We examine what rPPG-style detectors learn on Celeb-DF++ (22 forgery methods) and FaceForensics++ (FF++), using one identically sampled window per real and fake video. On talking-face forgeries, simple chrominance traces reach an AUC of 0.998, exceeding a dedicated rPPG extractor (0.87). Controlled experiments indicate that this signal is not physiological in origin. On fully synthesized forgeries, it is equally discriminative when extracted from background regions or from full frames without face detection, and it is concentrated above the 0.7 to 4 Hz heart-rate band. It is largely removed by shuffling frame order but persists after normalizing resolution, frame rate and encoding, and an independent reimplementation reproduces these findings. Removing high-frequency content makes most synthesized videos appear real, adding it makes real videos appear fake, and injecting a synthetic pulse has little effect. In controlled self-reenactment experiments with two generators, animating a face from a single frame introduces the same high-frequency signal, whereas reconstructing each frame from its own source does not. Face-based chrominance detectors trained on Celeb-DF++ classify over 99% of real FF++ videos as fake, indicating that they largely encode video source rather than manipulation, and a CLIP-based detector exhibits the same behavior. A frozen CLIP backbone matches or exceeds fusions of CLIP with rPPG and frequency features. Finally, we show that the official Celeb-DF and Celeb-DF++ splits share identities and source-video content between training and test, and that custom protocols reusing test videos and identities in training inflate weaker detectors by up to 0.30 AUC.

0.18

Cross-Dataset Transfer and Reliability of Explainable Artificial Intelligence for RhythmFormer Remote Photoplethysmography

cs.CV cs.AIeess.IV ·2026-09-03 ·Louis Chen, Torbjörn E. M. Nordling
similarity 0.63
Abstract · 92 pages, 38 figures, incl. supplementary

Background. Remote photoplethysmography estimates the cardiovascular pulse from facial video, and its explanations have rested on inspecting heatmaps rather than on quantitative evidence about where a model reads it. We quantified the explanations and asked whether such explanations transfer between datasets and track model performance. Method. We trained eight condition-specific RhythmFormer models on NCKU-rPPG, recorded under three illumination levels, speaking, rotation, and cycling, estimated one heart rate per 5.12-second clip, and set them beside a UBFC-rPPG reproduction. Raw attention, rollout, attention flow, and Beyond Intuition were assessed by skin coverage and the Salience-guided Faithfulness Coefficient (SaCo). Results. Beyond Intuition ranked highest on both datasets, at median coverage 0.789 and SaCo 0.837 on Static level 3 against 0.826 and 0.917 on UBFC-rPPG; lower ranks differed. Within one participant of one condition, neither measure was related to a clip's heart-rate error, waveform correlation, or signal-to-noise ratio on either dataset: 186 of the 252 coefficients fell below $|ρ|=0.10$ and 28 reached $p<0.05$ against the 13 expected by chance. Across the eight scenarios only Beyond Intuition's coverage followed the three performance measures, at $ρ=-0.43$, $+0.57$, and $+0.43$, while the attention-only methods' SaCo ran opposite to each. It failed at 40 lux alone, its median coverage falling to 0.180 and its median SaCo to $-0.178$, whereas motion degraded the estimates far more without such a drop. Conclusions. Skin coverage and SaCo carry information complementary to the performance measures rather than a proxy for them: attributing to the skin does not guarantee an accurate estimate. What an attribution reveals about a condition is where the model looks rather than how faithfully its map is ordered.

0.27

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

cs.CV ·2026-09-30 ·Bo Zhao, Junzhe Cao, Dan Guo, Dongmin Huang, Wenjin Wang +3 more
similarity 0.62
Abstract

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose \textbf{FLOW (Feature-Level Optimal Warping)}, an \emph{optimal transport--driven} framework for domain-generalized rPPG. FLOW integrates a \textbf{Temporal Refinement Module (TRM)} to stabilize temporal dynamics and a \textbf{Prototype-based Cross-Temporal Optimal Transport (PCOT)} module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.

0.43

Beyond Ambiguous Visual Cues: Studying Physiological Disruptions and Cross-Modal Inconsistencies in Deepfake Videos

cs.CV ·2026-09-11 ·Chenxi Yang, Yassine Ouzar, Larbi Boubchir
similarity 0.62
Abstract

Recent deepfake detection studies increasingly suggest remote photoplethysmography (rPPG) signals as an authenticity cue. However, existing benchmarks lack physiological ground truth, and current detectors underexplore the cross-level relationship between facial features and physiological dynamics, often relying on late fusion or rPPG features alone. In this paper, we construct high-fidelity deepfake manipulations on established real rPPG datasets (COHFACE and UBFC-rPPG) to investigate how forgeries disrupt natural physiological signals and facial behavior at the same time. Building on this analysis, we propose a bidirectional co-attention fusion detector that jointly models rPPG and facial behavior tokens. This mechanism explicitly captures the cross-level dependencies between pulse dynamics and facial motion to learn a robust, joint authenticity representation. Extensive experiments using a subject-disjoint 5-fold evaluation demonstrate the superiority of our approach. Achieving a 92.80\% AUC on constructed datasets using face swapping and 96.78\% AUC on motion transfer, our model outperforms both the rPPG-only single modality baseline and the best feature-level fusion methods. Furthermore, transfer-learning result of the fusion detector on Celeb-DF-v2 while keeping both feature extractors fixed achieves 91.20\% accuracy and 86.08\% AUC, which suggests applicability under target-domain adaptation.

0.19