CS Paper Radar

Cross-Dataset Transfer and Reliability of Explainable Artificial Intelligence for RhythmFormer Remote Photoplethysmography

Louis Chen, Torbjörn E. M. Nordling

cs.CV cs.AIeess.IV ·submitted 2026-09-03 10:59 UTC · v1

Abstract

Background. Remote photoplethysmography estimates the cardiovascular pulse from facial video, and its explanations have rested on inspecting heatmaps rather than on quantitative evidence about where a model reads it. We quantified the explanations and asked whether such explanations transfer between datasets and track model performance. Method. We trained eight condition-specific RhythmFormer models on NCKU-rPPG, recorded under three illumination levels, speaking, rotation, and cycling, estimated one heart rate per 5.12-second clip, and set them beside a UBFC-rPPG reproduction. Raw attention, rollout, attention flow, and Beyond Intuition were assessed by skin coverage and the Salience-guided Faithfulness Coefficient (SaCo). Results. Beyond Intuition ranked highest on both datasets, at median coverage 0.789 and SaCo 0.837 on Static level 3 against 0.826 and 0.917 on UBFC-rPPG; lower ranks differed. Within one participant of one condition, neither measure was related to a clip's heart-rate error, waveform correlation, or signal-to-noise ratio on either dataset: 186 of the 252 coefficients fell below $|ρ|=0.10$ and 28 reached $p<0.05$ against the 13 expected by chance. Across the eight scenarios only Beyond Intuition's coverage followed the three performance measures, at $ρ=-0.43$, $+0.57$, and $+0.43$, while the attention-only methods' SaCo ran opposite to each. It failed at 40 lux alone, its median coverage falling to 0.180 and its median SaCo to $-0.178$, whereas motion degraded the estimates far more without such a drop. Conclusions. Skin coverage and SaCo carry information complementary to the performance measures rather than a proxy for them: attributing to the skin does not guarantee an accurate estimate. What an attribution reveals about a condition is where the model looks rather than how faithfully its map is ordered.

Comment
92 pages, 38 figures, incl. supplementary

Closest papers

Nearest neighbours by meaning across the whole index.

Heartian: Physiology-Aware Relightable Gaussian Head Avatar

cs.CV cs.GR ·2026-09-22 ·Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Akşit
publishedbenchmark similarity 0.63
Abstract · 4 pages of manuscript and 2 pages of supplementary material; SIGGRAPH Asia 2026 Technical Communications

Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose Heartian, a physiology-aware modulation framework that learns cardiac-cycle-dependent per-frame albedo modulation of facial skin-region Gaussians within a relightable head avatar to encode remote photoplethysmography (rPPG) signals. Using synchronized contact PPG supervision, Heartian models the prescribed cardiac waveform as the sum of two Gaussian functions and learns per-frame spatial residuals via a lightweight MLP. Across 152 stationary recordings from UBFC-rPPG, PURE, and MMPD, attribute-space recovery of the supplied signal achieves a pooled recording-level heart-rate MAE of 0.29 bpm and MAPE of 0.38%. The signals remain detectable after rendering by benchmark rPPG methods, with the best tested configuration - a motion-augmented TS-CAN decoder pretrained on UBFC-rPPG - recovering heart rate from the rendered MMPD avatars at 0.97 bpm MAE and 1.21% MAPE. Meanwhile, Heartian maintains reconstruction quality comparable to the baseline, with negligible average PSNR degradation of 0.005 dB. Overall, our work embeds recoverable rPPG signals as controllable material attributes to subject-specific Gaussian head avatars while retaining the reconstruction quality.

0.24

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.60
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Quality and Similarity Indicators for Video-Based Heart Rate and Respiratory Rate Fusion: A Controlled Evaluation

cs.CV ·2026-11-16 ·Nhi Nguyen, Le Nguyen, Manuel Lage Cañellas, Miguel Bordallo López, Constantino Álvarez Casado
similarity 0.60
Abstract · 15 pages, 7 figures, 4 tables; with 14 pages supplementary material included

Camera-based heart rate (HR) and respiratory rate (RR) estimates vary in reliability from window to window, and a common remedy is to fuse several extraction methods with weights from reference-free signal quality indicators. However, few studies test whether these indicators identify the most accurate method in each window or outperform simpler fusion. We evaluate 11 quality indicators and 8 inter-method similarity measures for fusing 7 HR and 10 RR extractors on four public datasets (75 test subjects). Filters, indicator directions, weighting parameters and a learned ridge baseline are selected on a separate five-subject set before testing. Fusion is compared with equal averaging, a constant typical-rate predictor, the best single method selected in advance and in hindsight, and a per-window oracle with a permutation-based null, using subject-level bootstrap confidence intervals. For HR, quality-weighted fusion reduced mean absolute error by 10.9% [5.2, 18.4] relative to averaging and by 15.6% [8.1, 23.1] relative to the method selected in advance, and was statistically indistinguishable from the best method selected in hindsight. Weighting methods by their agreement did not improve on averaging. For RR, the indicators could not identify the more accurate estimates: sharpened quality weighting increased error (-2.6% [-4.8, -0.8]), fused estimates were uncorrelated with the reference (r <= 0.22), and averaging was less accurate than the typical-rate predictor (-3.1% [-6.1, -0.4]). With a second respiratory reference, apparent RR gains reflected estimates moving toward its typical rate. Quality-guided fusion is worthwhile for video HR; for RR, 30-s windows improved estimates but not fusion.

0.26

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

cs.CV ·2026-08-30 ·Zixu Li, Jianjun Qian, Hang Shao, Daoheng Li, Lei Luo +1 more
similarity 0.60
Abstract

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.

0.29

Property-Specific Recoverability from Contact PPG to Camera rPPG under Heterogeneous Observation Conditions

eess.SP cs.AI ·2026-08-27 ·Timothy Oladunni, Farouk Ganiyu-Adewumi
similarity 0.58
Abstract

Camera-derived remote photoplethysmography (rPPG) is commonly validated through endpoint accuracy, but endpoint performance does not establish whether other physiological properties of source contact photoplethysmography (PPG) remain preserved recording by recording. We evaluated property-specific PPG-to-rPPG recoverability on 655 recordings from the Multi-Domain Mobile Video Physiology Dataset using CHROM as a fixed camera-rPPG observation pathway. The pathway reproduced the published CHROM correlation regime, with heart-rate MAE of 15.26 bpm and Pearson correlation of 0.0801. Matched-versus-shuffled validation revealed modest recording-specific autocorrelation correspondence, while spectral and recurrence-rate measures showed little matched discrimination. Maximal Lyapunov exponents showed essentially no recording-specific PPG-to-rPPG correspondence, with correlation of 0.0231 and permutation p-value of 0.5584, despite population-level overlap. Endpoint discrepancy exhibited Fitzpatrick-associated heterogeneity after adjustment for lighting and motion, including a Fitzpatrick VI versus III contrast of 9.32 bpm, while dynamical discrepancy showed no corresponding gradient. Aggregate RGB signal-to-noise ratio did not materially account for the endpoint contrast. In subject-held-out analysis, adding motion and lighting consistently reduced MAE across linear, ridge, and random-forest learners relative to rPPG-HR-only calibration, with reductions up to 13.32 percent. These findings show that recoverability is property-specific: physiological properties differ in recording-specific preservation and dependence on observation conditions, and population-level plausibility does not establish preservation of individual recordings.

0.27

PulseBound: Future-Beat State Forecasting Under an Explicit Information Boundary

cs.AI ·2026-10-08 ·Chenyang Xu, Donglin Xie, Xi Xiang, Xiaoyu Li, Yufan Lu +10 more
similarity 0.58
Abstract · under review

Predictive representation learning from photoplethysmography (PPG) can violate causal information access even with causal attention, as normalization, nonlocal transforms, or companion views may depend on withheld samples. We introduce PulseBound, a PPG representation learner combining physiologically structured future-beat prediction with an explicit stored-window information boundary. A content-independent cutoff separates the visible prefix from the prediction target. Prefix-only normalization, suffix replacement before derived-view construction, and aligned masking ensure that encoder inputs depend only on the visible prefix and cutoff. This yields stored-suffix invariance: with fixed model state, randomness, prefix, and cutoff, changing the stored suffix cannot change the forecast context. A shared horizon-conditioned head predicts nine rhythm and morphology descriptors for up to four extractor-valid future beats, using elementwise validity masks; optional ECG-derived pulse-arrival-time supervision is restricted to training. On MIMIC and VitalDB groups held out from PulseBound backbone pretraining, PulseBound reduces nine-state transformed-space MAE relative to last-visible-beat persistence by 28.06% and 22.22%, respectively, with gains in MAE, MAE-Skill, and Spearman correlation across all 40 source-cutoff-horizon cells. In a separate comparison of seven models on 13 downstream tasks, PulseBound achieves the best mean on nine frozen linear-probe and seven full-fine-tuning tasks. Stored-suffix interventions cause zero recorded changes in forecast contexts or predictions, with zero suffix-input gradients at audited precision under the stored-window interface. These findings separate three testable aspects of predictive physiological representation learning: information access, supervised future structure, and transfer.

0.30

Beyond Ambiguous Visual Cues: Studying Physiological Disruptions and Cross-Modal Inconsistencies in Deepfake Videos

cs.CV ·2026-09-11 ·Chenxi Yang, Yassine Ouzar, Larbi Boubchir
similarity 0.57
Abstract

Recent deepfake detection studies increasingly suggest remote photoplethysmography (rPPG) signals as an authenticity cue. However, existing benchmarks lack physiological ground truth, and current detectors underexplore the cross-level relationship between facial features and physiological dynamics, often relying on late fusion or rPPG features alone. In this paper, we construct high-fidelity deepfake manipulations on established real rPPG datasets (COHFACE and UBFC-rPPG) to investigate how forgeries disrupt natural physiological signals and facial behavior at the same time. Building on this analysis, we propose a bidirectional co-attention fusion detector that jointly models rPPG and facial behavior tokens. This mechanism explicitly captures the cross-level dependencies between pulse dynamics and facial motion to learn a robust, joint authenticity representation. Extensive experiments using a subject-disjoint 5-fold evaluation demonstrate the superiority of our approach. Achieving a 92.80\% AUC on constructed datasets using face swapping and 96.78\% AUC on motion transfer, our model outperforms both the rPPG-only single modality baseline and the best feature-level fusion methods. Furthermore, transfer-learning result of the fusion detector on Celeb-DF-v2 while keeping both feature extractors fixed achieves 91.20\% accuracy and 86.08\% AUC, which suggests applicability under target-domain adaptation.

0.19

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.57
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16