CS Paper Radar

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

Zixu Li, Jianjun Qian, Hang Shao, Daoheng Li, Lei Luo, Jian Yang

cs.CV ·submitted 2026-08-30 08:56 UTC · v1

Abstract

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.

Closest papers

Nearest neighbours by meaning across the whole index.

Why Do VLMs Fail at Remote Physiological Measurement? Rethinking with Physiological Grounding and Numerical Alignment

cs.CV ·2026-10-13 ·Xiao Yang, Zekun Zhang, Yuxuan Fan, Duoxun Tang, Ziyang Liu +3 more
similarity 0.66
Abstract

Video-based remote physiological measurement (RPM) has broad applications, while Vision-Language Models (VLMs) provide a promising opportunity to enable end-to-end physiological monitoring for future human-aware intelligent systems. However, existing RPM methods rely on task-specific models and cannot be seamlessly integrated with the multimodal understanding and interaction capabilities of VLMs. We revisit RPM with VLMs and provide empirical evidence for two major bottlenecks: generic visual semantic representations fail to preserve fine-grained physiological cues; while discrete token prediction in autoregressive generation is inherently misaligned with continuous numerical measurement. To address these challenges, we propose VITAL (Visual-physiological Token Alignment for Language Models), a visual-physiological token alignment framework for RPM and preserving general vision tasks. VITAL retains the original visual pathway for semantic understanding and introduces an independent physiological pathway to jointly model semantic and physiological information. Moreover, we propose a structured numerical alignment approach to improve the reliability of generative heart rate estimation by enhancing numerical relationship modeling. Extensive experiments show that VITAL improves cross-domain estimation performance on multiple rPPG datasets while preserving the general visual understanding capability of VLMs, demonstrating its effectiveness as a unified visual-physiological model. Code will be released.

0.21

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.65
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

Heartian: Physiology-Aware Relightable Gaussian Head Avatar

cs.CV cs.GR ·2026-09-22 ·Xiaoyue Fan, Jose Echevarria, Akshay Paruchuri, Kaan Akşit
publishedbenchmark similarity 0.64
Abstract · 4 pages of manuscript and 2 pages of supplementary material; SIGGRAPH Asia 2026 Technical Communications

Gaussian head avatars typically model intrinsic facial appearance as temporally static, omitting subtle cardiac-induced skin-color variation. We propose Heartian, a physiology-aware modulation framework that learns cardiac-cycle-dependent per-frame albedo modulation of facial skin-region Gaussians within a relightable head avatar to encode remote photoplethysmography (rPPG) signals. Using synchronized contact PPG supervision, Heartian models the prescribed cardiac waveform as the sum of two Gaussian functions and learns per-frame spatial residuals via a lightweight MLP. Across 152 stationary recordings from UBFC-rPPG, PURE, and MMPD, attribute-space recovery of the supplied signal achieves a pooled recording-level heart-rate MAE of 0.29 bpm and MAPE of 0.38%. The signals remain detectable after rendering by benchmark rPPG methods, with the best tested configuration - a motion-augmented TS-CAN decoder pretrained on UBFC-rPPG - recovering heart rate from the rendered MMPD avatars at 0.97 bpm MAE and 1.21% MAPE. Meanwhile, Heartian maintains reconstruction quality comparable to the baseline, with negligible average PSNR degradation of 0.005 dB. Overall, our work embeds recoverable rPPG signals as controllable material attributes to subject-specific Gaussian head avatars while retaining the reconstruction quality.

0.24

Beyond Ambiguous Visual Cues: Studying Physiological Disruptions and Cross-Modal Inconsistencies in Deepfake Videos

cs.CV ·2026-09-11 ·Chenxi Yang, Yassine Ouzar, Larbi Boubchir
similarity 0.63
Abstract

Recent deepfake detection studies increasingly suggest remote photoplethysmography (rPPG) signals as an authenticity cue. However, existing benchmarks lack physiological ground truth, and current detectors underexplore the cross-level relationship between facial features and physiological dynamics, often relying on late fusion or rPPG features alone. In this paper, we construct high-fidelity deepfake manipulations on established real rPPG datasets (COHFACE and UBFC-rPPG) to investigate how forgeries disrupt natural physiological signals and facial behavior at the same time. Building on this analysis, we propose a bidirectional co-attention fusion detector that jointly models rPPG and facial behavior tokens. This mechanism explicitly captures the cross-level dependencies between pulse dynamics and facial motion to learn a robust, joint authenticity representation. Extensive experiments using a subject-disjoint 5-fold evaluation demonstrate the superiority of our approach. Achieving a 92.80\% AUC on constructed datasets using face swapping and 96.78\% AUC on motion transfer, our model outperforms both the rPPG-only single modality baseline and the best feature-level fusion methods. Furthermore, transfer-learning result of the fusion detector on Celeb-DF-v2 while keeping both feature extractors fixed achieves 91.20\% accuracy and 86.08\% AUC, which suggests applicability under target-domain adaptation.

0.19

Subject-Relative Micro-Motion and Sleep Dynamics for Near-Infrared Video Sleep Staging

cs.CV cs.AI ·2026-09-03 ·Kunmin Jang, You Rim Choi, Hun Heo, Heonjun Lee, Suahn Bae +3 more
similarity 0.63
Abstract

Near-infrared (NIR) video is a promising modality for contactless sleep monitoring, but recent video-based sleep staging methods often use it as a route to reconstructed respiratory/cardiac proxies or cross-modal physiological representations. We study video-only sleep staging under labels defined by polysomnography (PSG), where the model infers sleep stages from NIR video alone without explicit physiological proxy reconstruction or auxiliary physiological signal supervision. This tests whether NIR video itself can provide informative sleep-stage evidence, rather than only serving as an input for recovering physiological proxies. We propose ViNUSS (Video-Native Unmediated Sleep Staging), a framework that combines subject-relative micro-motion learning with full-night sleep dynamics modeling. Spatially anchored pre-spatial micro-motion encoding preserves localized temporal variation together with its spatial context. Within-subject stage contrast learns stage cues with respect to each subject's night-specific baseline. Two-scale sleep dynamics modeling captures within-epoch motion evolution and organizes epoch-level evidence into a coherent full-night sleep-stage trajectory. On 475 overnight NIR recordings (~3,250 hours), ViNUSS achieves 0.80 accuracy and 0.78 macro-F1 for four-class sleep staging. Interpretability analysis suggests attention to thoraco-abdominal periodic motion and gross body movements associated with arousals and position changes. These results support NIR video as an independently informative and complementary modality for PSG-defined sleep-stage estimation

0.19

CALM-BP: Observation-Matched Physiological Semantic Grounding for Non-Contact Blood Pressure Estimation

cs.HC ·2026-08-22 ·Haiyang Sun, Boyuan Gu, Yongjie Liu
similarity 0.62
Abstract · 17 pages, 3 figures, 12 tables

Language grounding increasingly involves non-text observations whose structure is not naturally expressed as words or objects. We study this problem for physiological time series in non-contact blood pressure (BP) estimation: remote photoplethysmography (rPPG) provides measured evidence about bodily state, but numerical pipelines expose little semantic structure about why a window is reliable or how its cues should be fused. We introduce observation-matched physiological semantic grounding, where language-derived priors must be constructed from the same rPPG observation, remain bounded by an auditable prior contract, and avoid BP-label or identity leakage. CALM-BP does not treat language as new physiological evidence; instead, it verbalizes rPPG descriptors into a controlled semantic interface while rPPG remains the primary haemodynamic evidence source. FlowBP-Set pairs forehead observations, synchronized BP labels, and structured physiological prompts from 81 participants. Main BP results, direct cross-dataset evaluation, language-realization ablation, and observation-mismatch controls test whether language helps because it organizes the current physiological observation rather than because it is arbitrary auxiliary text. The FlowBP-Set dataset contains sensitive facial video and physiological recordings and is therefore not publicly available due to privacy and ethical restrictions. Data access may be considered upon reasonable request and subject to applicable ethical and institutional approval.

0.16

EgoHRV: Continuous Heart Rate Variability Estimation from Egocentric Systems for Autonomic Response and Skill Assessment

cs.CV eess.SP ·2026-08-19 ·Berken Utku Demirel, Christian Holz
top venuecode/data similarity 0.60
Abstract · Accepted to the European Conference on Computer Vision (ECCV) 2026

Egocentric vision systems capture human behavior from visible cues, but overlook physiological indicators of autonomic states such as stress, engagement, and attention. Heart rate variability (HRV) is a widely used noninvasive marker of autonomic regulation under stress. HRV reflects small timing differences between successive heartbeats and has so far been out of reach for egocentric platforms, where motion and noise in gaze video mask exactly this fine-grained timing. We propose EgoHRV, a method that estimates HRV as well as heart rate (HR) from the gaze cameras that are already integrated into egocentric headsets. Our pipeline combines a 3D backbone with a novel low--high decomposition module that extracts the blood volume pulse (BVP) signal from gaze video. Our cross-domain pretraining aligns the frequency-domain representations of contact-based and camera-derived signals. This alignment gives EgoHRV the temporal precision to recover HRV from the subtle fluctuations in gaze video. EgoHRV achieves state-of-the-art accuracy for HR and HRV estimation from egocentric video, and its uncertainty-aware design improves downstream behavioral modeling. Integrating our HRV estimates and confidence measures into EgoExo4D's proficiency estimator raises accuracy by 17.8%. Beyond skill, continuous HRV estimation also opens egocentric systems to stress- and arousal-aware estimation tasks. Code: https://github.com/eth-siplab/EgoHRV

0.48

Pixel-wise Exposure for Highly Robust In-Vehicle Remote-PPG

cs.CV ·2026-09-29 ·Jieying Wang, Xinqi Cai, Caifeng Shan, Wenjin Wang
similarity 0.60
Abstract

Remote photoplethysmography (rPPG) offers a promising non-contact solution for heart rate monitoring, yet its real-world robustness is fundamentally limited by an inherent hardware limitation: existing camera exposure control paradigms, whether fixed or auto-exposure, impose a uniform exposure time across all pixels within a frame. In high-dynamic-range scenes such as automotive cabins with strong directional sunlight, this spatially invariant exposure constraint inevitably leads to localized facial overexposure or underexposure, irreversibly corrupting the subtle pulsatile signals essential for rPPG at the point of capture, a physical degradation that no downstream algorithm can recover. To overcome this bottleneck, we propose PixExpo (Pixel-wise Exposure), a "temporal-for-spatial" framework that sequentially captures frames under a predefined cyclic exposure schedule and performs non-iterative pixel-wise fusion. At each pixel location, PixExpo selects the observation closest to an rPPG-motivated target intensity. This criterion seeks to reduce local saturation and severe underexposure rather than optimize perceptual appearance. PixExpo requires no sensor modification but assumes programmable frame-level exposure control. We validate the proposed PixExpo framework using our newly introduced MEX-Drive dataset, comprising 48 participants under real-world driving conditions. Experimental results demonstrate that PixExpo outperforms manufacture-default auto-exposure methods, reducing the mean absolute error (MAE) by 7.21 bpm (from 13.94 to 6.73 bpm) and increasing the success rate by 37.29 percentage points (from 25.95% to 63.24%) across challenging driving scenarios.

0.21