CS Paper Radar

CALM-BP: Observation-Matched Physiological Semantic Grounding for Non-Contact Blood Pressure Estimation

Haiyang Sun, Boyuan Gu, Yongjie Liu

cs.HC ·submitted 2026-08-22 02:52 UTC · v1

Abstract

Language grounding increasingly involves non-text observations whose structure is not naturally expressed as words or objects. We study this problem for physiological time series in non-contact blood pressure (BP) estimation: remote photoplethysmography (rPPG) provides measured evidence about bodily state, but numerical pipelines expose little semantic structure about why a window is reliable or how its cues should be fused. We introduce observation-matched physiological semantic grounding, where language-derived priors must be constructed from the same rPPG observation, remain bounded by an auditable prior contract, and avoid BP-label or identity leakage. CALM-BP does not treat language as new physiological evidence; instead, it verbalizes rPPG descriptors into a controlled semantic interface while rPPG remains the primary haemodynamic evidence source. FlowBP-Set pairs forehead observations, synchronized BP labels, and structured physiological prompts from 81 participants. Main BP results, direct cross-dataset evaluation, language-realization ablation, and observation-mismatch controls test whether language helps because it organizes the current physiological observation rather than because it is arbitrary auxiliary text. The FlowBP-Set dataset contains sensitive facial video and physiological recordings and is therefore not publicly available due to privacy and ethical restrictions. Data access may be considered upon reasonable request and subject to applicable ethical and institutional approval.

Comment
17 pages, 3 figures, 12 tables

Closest papers

Nearest neighbours by meaning across the whole index.

HiPPT: Physiology-Grounded Wearable PPG Representation Learning via Multi-Scope Text Alignment

cs.AI ·2026-10-10 ·Jiaqi Wang, Wei Chen, Xiaoyu Li, Lexian Xia, ShuaiLong Tang +5 more
similarity 0.68
Abstract

Reusable wearable PPG representations should capture local pulse morphology and broader physiological regularities. Existing pretraining objectives, however, usually apply supervision at the recording or pair level, overlooking that different concepts become reliable over different scopes of waveform evidence. We propose HiPPT, a physiology-grounded framework that matches each supervision source to its appropriate evidence scope. We construct a PPG-Text corpus of over 4 million wrist-worn recordings from 202K users, pairing recordings with waveform-derived morphology and metadata-derived context descriptions. HiPPT combines record-level morphology alignment, which grounds individual recordings in pulse characteristics, with cross-recording context alignment, which aggregates recordings sharing the same metadata tuple to capture context-consistent regularities. Waveform-guided text modeling further recovers masked contextual concepts from PPG patch representations, providing fine-grained waveform-text supervision. Across six downstream tasks spanning blood pressure, vascular stiffness, physiological attributes, and cross-dataset heart-rate estimation, HiPPT achieves the best result on the primary linear-probing metrics. The aligned space also supports zero-shot profiling of age group, sex, and BMI category, individually and jointly, with performance improving as more recordings are aggregated. These results show that evidence-scope matching yields transferable and semantically accessible wearable PPG representations. Code and pretrained weights will be released.

0.23

PPG-LM: A Photoplethysmography-Language Model with Multi-Level Clinical Alignment

cs.AI ·2026-09-27 ·Xiaoda Wang, Minxiao Wang, Maxwell A Xu, Patrick Langer, Kaiqiao Han +8 more
similarity 0.65
Abstract

Photoplethysmography (PPG) is widely recorded by clinical monitors and consumer wearables, providing a scalable source of continuous physiological information. These recordings offer an opportunity for physiological assessment at scale, but realizing this potential requires models to learn from both signal-derived physiological supervision and broader clinical context captured in electronic health records (EHRs). This involves aligning information spanning local observations, care events, and entire visits with PPG representations at corresponding temporal scales. However, existing PPG foundation models primarily rely on task-specific prediction heads, while the medical knowledge of large language models does not necessarily translate into waveform understanding. To bridge this gap, we introduce PPG-LM, the first PPG-language model family to learn physiological representations from both signal-derived supervision and broader clinical context captured in EHRs. To construct clinically grounded captions, we develop an automatic captioning pipeline that generates segment-, event-, and visit-level descriptions from signal measurements and structured EHR records. We then learn from these pairs through a two-stage framework that first establishes segment-language correspondence through contrastive learning and waveform-conditioned captioning, then extends alignment to events and visits through time-aware aggregation and temporal statement matching. Pretrained on approximately 73k hours of PPG, PPG-LM supports language-based recognition, cross-modal retrieval, and segment captioning. Experiments on MC-MED, MIMIC-III, and VitalDB show improved retrieval and caption factuality over language-model baselines and gains over PPG and time-series foundation models on multiple clinical prediction tasks.

0.36

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

cs.AI ·2026-10-21 ·Farouk Ganiyu Adewumi, Timothy Oladunni
similarity 0.63
Abstract

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

0.24

PhysVR: Vision-Language Model Guided Interference-aware Temporal Feature Refinement for Remote Physiological Measurement

cs.CV ·2026-08-30 ·Zixu Li, Jianjun Qian, Hang Shao, Daoheng Li, Lei Luo +1 more
similarity 0.62
Abstract

Remote photoplethysmography (rPPG) enables contactless physiological measurement from facial videos, yet its subtle pulse-related variations are easily affected by illumination variation, head motion, facial blur, and region-of-interest instability. Existing methods mainly suppress interference during feature learning, while whether the learned temporal features remain affected by interference and how to further suppress such interference before rPPG estimation are rarely examined. To address this limitation, we propose PhysVR, a vision-language model guided interference-aware temporal feature refinement framework for rPPG estimation. Specifically, a physiological backbone produces global temporal features and a coarse rPPG prediction, from which signal-derived physiological reliability evidence is constructed from local temporal characteristics. In parallel, a frozen vision-language model processes sampled facial frames under an interference-oriented prompt, and an evidence head extracts visual interference evidence from the VLM output. Temporal cross-attention integrates the physiological and visual evidence with the global temporal features to construct interference-aware temporal context. Guided by this context, a shared temporal correction unit performs general refinement, while four interference-specific experts selectively suppress different interference through adaptive routing. The refined temporal features are then used for final rPPG estimation. Extensive experiments on five public benchmarks demonstrate that PhysVR consistently outperforms representative methods under both intra-dataset and cross-dataset evaluation protocols.

0.29

Why Do VLMs Fail at Remote Physiological Measurement? Rethinking with Physiological Grounding and Numerical Alignment

cs.CV ·2026-10-13 ·Xiao Yang, Zekun Zhang, Yuxuan Fan, Duoxun Tang, Ziyang Liu +3 more
similarity 0.61
Abstract

Video-based remote physiological measurement (RPM) has broad applications, while Vision-Language Models (VLMs) provide a promising opportunity to enable end-to-end physiological monitoring for future human-aware intelligent systems. However, existing RPM methods rely on task-specific models and cannot be seamlessly integrated with the multimodal understanding and interaction capabilities of VLMs. We revisit RPM with VLMs and provide empirical evidence for two major bottlenecks: generic visual semantic representations fail to preserve fine-grained physiological cues; while discrete token prediction in autoregressive generation is inherently misaligned with continuous numerical measurement. To address these challenges, we propose VITAL (Visual-physiological Token Alignment for Language Models), a visual-physiological token alignment framework for RPM and preserving general vision tasks. VITAL retains the original visual pathway for semantic understanding and introduces an independent physiological pathway to jointly model semantic and physiological information. Moreover, we propose a structured numerical alignment approach to improve the reliability of generative heart rate estimation by enhancing numerical relationship modeling. Extensive experiments show that VITAL improves cross-domain estimation performance on multiple rPPG datasets while preserving the general visual understanding capability of VLMs, demonstrating its effectiveness as a unified visual-physiological model. Code will be released.

0.21

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

cs.CV ·2026-09-30 ·Bo Zhao, Junzhe Cao, Dan Guo, Dongmin Huang, Wenjin Wang +3 more
similarity 0.60
Abstract

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose \textbf{FLOW (Feature-Level Optimal Warping)}, an \emph{optimal transport--driven} framework for domain-generalized rPPG. FLOW integrates a \textbf{Temporal Refinement Module (TRM)} to stabilize temporal dynamics and a \textbf{Prototype-based Cross-Temporal Optimal Transport (PCOT)} module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.

0.43

Beyond Contact Sensors: Deep learning with Pseudo-Labeling for remote Photoplethysmography

cs.LG ·2026-09-09 ·Bhargav Acharya, Barbara Hammer, Hanna Drimalla
similarity 0.60
Abstract

Heart rate is a critical biomarker of health, and remote photoplethysmography (rPPG) enables its contactless estimation from video data for telemedicine applications. Recent advancements in deep learning based rPPG methods achieve state-of-the-art results, outperforming classical signal-processing methods in complex scenarios. However, deep learning methods depend on datasets with precise synchronization between videos and ground truth signals collected via contact sensors, whereas signal-processing-based methods do not. To address this dependence on labeled datasets, which are labor-intensive to collect, we investigate under which circumstances pseudo-labels extracted using unsupervised signal-processing methods can replace contact sensors labels for training deep learning methods. Our systematic evaluations found that for datasets with imperfect synchronization, the pseudo-label approach outperforms supervised training on contact sensors. For datasets with good synchronization, results are mixed: within-dataset evaluation shows no significant difference between training methods, while cross-dataset evaluation favors supervised training. However, removing a single outlier participant significantly improves the pseudo-label approach's cross-dataset performance, highlighting the importance of label quality. These results demonstrate that signal-processing methods can generate valid training signals for deep learning models, reducing dependency on labor-intensive dataset collection while maintaining competitive performance.

0.21

Large language models in medical time series analysis

eess.SP cs.AIcs.LG ·2026-09-07 ·Yu Han, Cigdem Beyan, Xiang Zhang, Xiaofeng Liu, Nan Liu +4 more
code/data similarity 0.60
Abstract

Medical time series (MedTS), including electrocardiograms (ECG), electroencephalograms (EEG), photoplethysmography (PPG), and vital-sign recordings, are central to clinical diagnosis and health monitoring. As large language models (LLMs) have advanced, a growing body of work has examined how their reasoning, generation, and knowledge-integration capabilities can support MedTS analysis. Yet existing studies remain scattered, and the field still lacks a clear view of how these models should be designed, integrated into clinical workflows, and evaluated. This review synthesizes recent work on large language models for medical time series analysis (MedTSLLMs), covering both methodological progress and issues related to real-world deployment. We review model architectures, data resources, and processing pipelines, and prompt design strategies adapted for diverse clinical scenarios. We further organize existing MedTS applications, ranging from diagnostic interpretation and report generation to longitudinal health monitoring and physiological signal synthesis, highlighting task-specific design choices, common evaluation protocols, and empirical findings reported across studies. By bringing together current practices and open challenges, this review aims to provide a clearer foundation for developing, evaluating, and deploying MedTSLLMs responsibly in healthcare. We also maintain a regularly updated list of MedTSLLM studies and resources at: https://github.com/hy727/MedTSLLM-Review.

0.34