CS Paper Radar

HiPPT: Physiology-Grounded Wearable PPG Representation Learning via Multi-Scope Text Alignment

Jiaqi Wang, Wei Chen, Xiaoyu Li, Lexian Xia, ShuaiLong Tang, Chenran Zhang, Donglin Xie, Guangpu Zhu, Yelei Li, Yi Zhou

cs.AI ·submitted 2026-10-10 02:38 UTC · v2

Abstract

Reusable wearable PPG representations should capture local pulse morphology and broader physiological regularities. Existing pretraining objectives, however, usually apply supervision at the recording or pair level, overlooking that different concepts become reliable over different scopes of waveform evidence. We propose HiPPT, a physiology-grounded framework that matches each supervision source to its appropriate evidence scope. We construct a PPG-Text corpus of over 4 million wrist-worn recordings from 202K users, pairing recordings with waveform-derived morphology and metadata-derived context descriptions. HiPPT combines record-level morphology alignment, which grounds individual recordings in pulse characteristics, with cross-recording context alignment, which aggregates recordings sharing the same metadata tuple to capture context-consistent regularities. Waveform-guided text modeling further recovers masked contextual concepts from PPG patch representations, providing fine-grained waveform-text supervision. Across six downstream tasks spanning blood pressure, vascular stiffness, physiological attributes, and cross-dataset heart-rate estimation, HiPPT achieves the best result on the primary linear-probing metrics. The aligned space also supports zero-shot profiling of age group, sex, and BMI category, individually and jointly, with performance improving as more recordings are aggregated. These results show that evidence-scope matching yields transferable and semantically accessible wearable PPG representations. Code and pretrained weights will be released.

Closest papers

Nearest neighbours by meaning across the whole index.

PPG-LM: A Photoplethysmography-Language Model with Multi-Level Clinical Alignment

cs.AI ·2026-09-27 ·Xiaoda Wang, Minxiao Wang, Maxwell A Xu, Patrick Langer, Kaiqiao Han +8 more
similarity 0.75
Abstract

Photoplethysmography (PPG) is widely recorded by clinical monitors and consumer wearables, providing a scalable source of continuous physiological information. These recordings offer an opportunity for physiological assessment at scale, but realizing this potential requires models to learn from both signal-derived physiological supervision and broader clinical context captured in electronic health records (EHRs). This involves aligning information spanning local observations, care events, and entire visits with PPG representations at corresponding temporal scales. However, existing PPG foundation models primarily rely on task-specific prediction heads, while the medical knowledge of large language models does not necessarily translate into waveform understanding. To bridge this gap, we introduce PPG-LM, the first PPG-language model family to learn physiological representations from both signal-derived supervision and broader clinical context captured in EHRs. To construct clinically grounded captions, we develop an automatic captioning pipeline that generates segment-, event-, and visit-level descriptions from signal measurements and structured EHR records. We then learn from these pairs through a two-stage framework that first establishes segment-language correspondence through contrastive learning and waveform-conditioned captioning, then extends alignment to events and visits through time-aware aggregation and temporal statement matching. Pretrained on approximately 73k hours of PPG, PPG-LM supports language-based recognition, cross-modal retrieval, and segment captioning. Experiments on MC-MED, MIMIC-III, and VitalDB show improved retrieval and caption factuality over language-model baselines and gains over PPG and time-series foundation models on multiple clinical prediction tasks.

0.36

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.69
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

CALM-BP: Observation-Matched Physiological Semantic Grounding for Non-Contact Blood Pressure Estimation

cs.HC ·2026-08-22 ·Haiyang Sun, Boyuan Gu, Yongjie Liu
similarity 0.68
Abstract · 17 pages, 3 figures, 12 tables

Language grounding increasingly involves non-text observations whose structure is not naturally expressed as words or objects. We study this problem for physiological time series in non-contact blood pressure (BP) estimation: remote photoplethysmography (rPPG) provides measured evidence about bodily state, but numerical pipelines expose little semantic structure about why a window is reliable or how its cues should be fused. We introduce observation-matched physiological semantic grounding, where language-derived priors must be constructed from the same rPPG observation, remain bounded by an auditable prior contract, and avoid BP-label or identity leakage. CALM-BP does not treat language as new physiological evidence; instead, it verbalizes rPPG descriptors into a controlled semantic interface while rPPG remains the primary haemodynamic evidence source. FlowBP-Set pairs forehead observations, synchronized BP labels, and structured physiological prompts from 81 participants. Main BP results, direct cross-dataset evaluation, language-realization ablation, and observation-mismatch controls test whether language helps because it organizes the current physiological observation rather than because it is arbitrary auxiliary text. The FlowBP-Set dataset contains sensitive facial video and physiological recordings and is therefore not publicly available due to privacy and ethical restrictions. Data access may be considered upon reasonable request and subject to applicable ethical and institutional approval.

0.16

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.66
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

Unlocking the Specialization Capability of PPG Foundation Models for Wearable Signals through Structured Pruning and Adaptive Fine-Tuning

cs.AI cs.LG ·2026-10-24 ·Huaming Du, Zhixian Xie, Gaoyang Zhen, Gang Kou, Guisong Liu +4 more
benchmark similarity 0.64
Abstract

Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. However, existing approaches to universal PPG representation learning are predominantly trained on high-quality large-scale datasets obtained from oximeters in hospital settings and often struggle to adapt to sparse and low-quality real-world datasets, thereby limiting their generalization to clinically relevant tasks on prevalent PPG data such as collected from wearable devices. Surprisingly, even after full fine-tuning, PPG foundation models cannot consistently outperform general-purpose time-series models. Therefore, a key question is how to effectively adapt PPG foundation models to target prediction tasks. Through empirical studies on various PPG foundation models, we find that pretrained models often exhibit inherent sparsity and computational redundancy, suggesting that PPG foundation models have learned to activate task-relevant network substructures for different prediction tasks. To preserve this valuable prior knowledge, we propose a structured pruning-and-fine-tuning framework, SPAFT, which regularizes the adaptive fine-tuning process by constraining it to a more relevant and compact parameter space based on parameter importance and structural redundancy. Extensive experiments across four PPG foundation models, five benchmark datasets, and ten downstream tasks demonstrate that SPAFT achieves win rates of 82.8% and 87.5% on regression and classification tasks, respectively. This prune-then-finetune paradigm often enables PPG foundation models to achieve state-of-the-art performance, laying a promising foundation for the real-world clinical deployment of PPG foundation models and the development of personalized PPG foundation models.

0.04

Pulseflow: PPG Counterfactual Generation Via Latent Transport

cs.LG ·2026-09-27 ·Hung Manh Pham, Dong Ma, Bin Zhu, Pan Zhou
code/data similarity 0.63
Abstract

Photoplethysmography (PPG) has become an important modality for continuous cardiovascular monitoring, including atrial fibrillation (AF) detection. However, labeled AF recordings remain limited in many clinical settings, making model adaptation difficult when only limited target data are available. Generative modeling offers a natural way to alleviate this scarcity by synthesizing additional AF signals. Existing approaches, however, mainly generate samples that match the target condition without explicitly modeling how an observed source recording should be transformed, making it difficult to leverage abundant source recordings from a specific population or cohort for targeted augmentation. We introduce PulseFlow, a source-conditioned counterfactual generation framework that combines conditional representation learning with invertible latent transport to edit cardiac rhythm while retaining information from the source. Experiments across two clinical cohorts demonstrate effective rhythm transformation, measurable source correspondence, and improved AF classification under limited labels.

0.24

ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG

cs.LG ·2026-09-28 ·Amir Arjomand, Kenneth B. Kent, Georgiy Krylov
published similarity 0.62
Abstract

Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.

0.21

The Impact of Temporal Context Length and Encoding Strategies on Self-Supervised ECG Representation Learning

cs.LG eess.SP ·2026-08-13 ·Ahmed Sameh, Ramzi Al-Sharawi, Yogatheesan Varatharajah
publishedcode/data similarity 0.62
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026). 6 pages, 2 figures…

Self-supervised electrocardiogram (ECG) models are often trained on a few seconds of ECG signal and, increasingly, on discretized token sequences. It remains unclear whether these choices sacrifice information needed for rhythm inference and longitudinal consistency in real-world ambulatory recordings. We present a controlled study on the Icentia11k single-lead dataset that varies (i) the input horizon (16 seconds, 1 minute, 5 minutes, and 10 minutes) and (ii) the front-end representation (continuous convolutional patch embeddings vs. fixed vector-quantized tokens), while holding the Transformer backbone and training protocol constant. Representations are assessed by downstream abnormal rhythm detection and by patient-level retrieval that probes cross-session stability. Our results show that increasing temporal context beyond 16-second snapshots yields stronger transfer and higher retrieval accuracy, with the strongest performance achieved by the 5- and 10-minute models, indicating improved capture of slow-varying rhythm dynamics and individual-specific structure. Across all evaluated horizons, continuous patch embeddings outperform discretized tokens, suggesting that quantization can discard clinically relevant waveform detail. These findings motivate ECG foundation models that emphasize extended context and continuous encoders for clinical prediction and similarity-based applications. Our code and pretrained models are publicly available at https://github.com/muha-0/ecg-ssl-representation-learning.

0.41