ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG

Amir Arjomand, Kenneth B. Kent, Georgiy Krylov

cs.LG ·submitted 2026-09-28 02:27 UTC · v1
published

Abstract

Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.

Closest papers

Nearest neighbours by meaning across the whole index.

Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

cs.ET cs.LG ·2026-11-12 ·Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin
surveybenchmark similarity 0.74
Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

0.10

Personalized and Explainable Blood Pressure Estimation from PPG via Hybrid CNN--Morphological Features

cs.CV ·2026-08-11 ·Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
published similarity 0.74
Abstract

Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, existing methods have two major limitations. Handcrafted feature-based approaches rely on precise fiducial point detection and are limited to short-term analysis, while deep learning models, despite their accuracy, often operate as black boxes with limited physiological interpretability. To address these challenges, we propose a physiology-guided hybrid framework for personalized BP estimation that couples a convolutional neural network (CNN) branch capturing global and local waveform dynamics with a morphology-prior branch that explicitly encodes person-specific vascular characteristics. By embedding a morphology-based feature set that explicitly encodes individual vascular characteristics, the proposed framework enhances personalization and reduces dependence on large-scale training datasets. Evaluated on a subset of the MIMIC-III database under a subject-specific (personalized) testing protocol, the proposed personalized physiology-guided hybrid approach achieved mean absolute errors (MAEs) of 3.77 mmHg for systolic BP and 2.36 mmHg for diastolic BP, corresponding to relative improvements of 43.7% and 32.4% over a subject-specific (personalized) CNN-only baseline. SHAP-based analysis confirmed that the introduced morphology-prior features align with individual vascular characteristics, reinforcing per-subject interpretability. These findings highlight the potential of personalized, physiology-guided hybrid learning with novel morphological descriptors for accurate and explainable BP monitoring in real-world settings.

0.57

A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction

cs.LG ·2026-08-24 ·Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
similarity 0.67
Abstract · 21 pages, 5 figures, 6 tables. Corrected typographical errors in two author email addresses; no changes to the scientific content

Objective. To develop and evaluate a cuffless continuous blood pressure (BP) estimator using temporal physiological and demographic features. We propose a hybrid Transformer framework to estimate diastolic and systolic BP from ECG/PPG-derived feature sequences. Approach. Rather than raw waveforms, the framework models 10-step sequences of six physiological descriptors and two demographic covariates. A Multi-Source Temporal Encoder Module combines Transformer, Kolmogorov-Arnold Network, and XGBoost branches to capture complementary temporal, nonlinear, and tabular information. A Dynamic Conditional Fusion-Decoder applies differential multi-head attention, token-weighted aggregation, and gated residual correction. A robust composite objective jointly optimizes DBP and SBP. Main results. Using the MIMIC-III Waveform and Clinical Databases, the source pool comprised 28,486 waveform segments from 203 subjects, and feature generation retained 53,621 observations from 166 subjects. On 2,431 segment-level held-out test windows, mean error +/- standard deviation was 0.41 +/- 3.74 mmHg for diastolic BP and -1.60 +/- 5.95 mmHg for systolic BP, with 95% limits of agreement of [-6.93, 7.74] and [-13.25, 10.06] mmHg, respectively. The proportions within 10 mmHg were 98.48% and 94.36%. The framework achieved the lowest standard deviations and narrowest limits of agreement among the locally retrained baselines. Significance. The feature-sequence fusion framework improved agreement with reference BP and fell within numerical AAMI and BHS Grade A thresholds on this split. This retrospective analysis is not formal device validation; subject-disjoint and external evaluation remain necessary before clinical use.

0.27

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.67
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

SIFPBPNet: A Dual-Path Network for Wearable and Cuffless Blood Pressure Estimation via Individualized Steady-state Representation

cs.LG ·2026-09-11 ·Shuailong Tang, Xiaoyu Li, Donglin Xie, Wei Chen, Guangpu Zhu +2 more
published similarity 0.65
Abstract · Accepted for publication at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026), To…

Continuous and cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) is of great interest for low-cost and personalized cardiovascular health management. However, significant population heterogeneity and the "one-to-many mapping" problem, where similar waveforms across individuals correspond to different BP levels, limit the accuracy of conventional population-based models. To address this challenge, we propose a dual-path architecture termed SIFPBPNet, which separately represents steady-state and instantaneous features, through a Steady-state Feature Path (SFP) and an Instantaneous Feature Path (IFP). The SFP employs a Graph Attention Network (GAT) to extract individual-specific and long-term characteristics from multi-day historical PPG trajectories. In parallel, the IFP captures short-term dynamics from current PPG segments and incorporates the steady-state prior via a cross-attention mechanism. Experiments on a large-scale wearable dataset demonstrate that SIFPBPNet achieves a Mean Absolute Error (MAE) of 8.57 and 5.97 mmHg for systolic and diastolic BP, respectively, outperforming state-of-the-art models. Furthermore, the SFP module consistently improves performance when integrated into various backbone architectures, yielding 2.8-13.1% relative MAE reductions for systolic BP. These results highlight the strong generalizability and plug-and-play transferability of the SFP module, underscoring its great potential for accurate cuffless BP monitoring.

0.39

HiPPT: Physiology-Grounded Wearable PPG Representation Learning via Multi-Scope Text Alignment

cs.AI ·2026-10-10 ·Jiaqi Wang, Wei Chen, Xiaoyu Li, Lexian Xia, ShuaiLong Tang +5 more
similarity 0.62
Abstract

Reusable wearable PPG representations should capture local pulse morphology and broader physiological regularities. Existing pretraining objectives, however, usually apply supervision at the recording or pair level, overlooking that different concepts become reliable over different scopes of waveform evidence. We propose HiPPT, a physiology-grounded framework that matches each supervision source to its appropriate evidence scope. We construct a PPG-Text corpus of over 4 million wrist-worn recordings from 202K users, pairing recordings with waveform-derived morphology and metadata-derived context descriptions. HiPPT combines record-level morphology alignment, which grounds individual recordings in pulse characteristics, with cross-recording context alignment, which aggregates recordings sharing the same metadata tuple to capture context-consistent regularities. Waveform-guided text modeling further recovers masked contextual concepts from PPG patch representations, providing fine-grained waveform-text supervision. Across six downstream tasks spanning blood pressure, vascular stiffness, physiological attributes, and cross-dataset heart-rate estimation, HiPPT achieves the best result on the primary linear-probing metrics. The aligned space also supports zero-shot profiling of age group, sex, and BMI category, individually and jointly, with performance improving as more recordings are aggregated. These results show that evidence-scope matching yields transferable and semantically accessible wearable PPG representations. Code and pretrained weights will be released.

0.23

Evaluating Generalization and Long-Term Stability of Smartwatch-Based Cuffless Blood Pressure Monitoring

eess.SP ·2026-10-29 ·Hongda Huang, Xiao Peng, Xiaoyu Li, Shuailong Tang, Guangpu Zhu +4 more
published similarity 0.62
Abstract · Accepted by the 2026 IEEE EMBS International Conference on Biomedical and Health Informatics (BHI 2026)

Smartwatch-based cuffless blood pressure (BP) monitoring is a promising low-burden solution for long-term cardiovascular management, but practical deployment remains constrained by model complexity, uncertain cross-dataset generalization, and insufficient evidence on long-term tracking stability. This study presents an efficient Signal-Context Gated Fusion Network (SCGBPNet) for cuffless BP estimation from photoplethysmography (PPG) signals. SCGBPNet integrates signal-level representations through self-attention and further incorporates subject-specific contextual information via a compact gated fusion module. On Aurora-BP, SCGBPNet achieved SBP/DBP mean absolute errors (MAEs) of 7.08/4.90 mmHg, compared with 6.44/4.89 mmHg under within-dataset validation on the private smartwatch dataset, indicating a modest within-dataset discrepancy. Cross-dataset transfer from Aurora-BP to the smartwatch dataset increased the MAEs to 8.98/6.47 mmHg, demonstrating substantial cross-dataset degradation. For long-term stability, the proposed method showed low week-to-week performance variation and a low daily decay rate, indicating good stability over a follow-up period of more than one month. Nevertheless, estimation accuracy deteriorated when BP deviated substantially from an individual's baseline. These findings indicate that favorable aggregate MAE alone should not be interpreted as evidence of deployment-ready performance. More systematic and stratified evaluation across dataset settings, BP ranges, and baseline-deviation levels is needed to assess the practical reliability of smartwatch-based cuffless BP monitoring.

0.25

Context-Augmented, Session-Calibrated Blood Pressure Tracking from Photoplethysmography

cs.AI ·2026-10-21 ·Farouk Ganiyu Adewumi, Timothy Oladunni
similarity 0.61
Abstract

Objective.To distinguish the contributions of acquisition context and photoplethysmography (PPG) to session-calibrated blood pressure (BP) tracking.Approach. The original comparison used three repeats of five-fold participant-level cross-validation in 653 AuroraBP participants, excluding calibration-labelled prediction targets. Matched analyses separated context and PPG and removed elapsed-time terms. Later exploratory follow-ups retained PPG, accelerometer signals and three initial cuff readings. Separate studies evaluated pulse-rate fusion and an intraoperative VitalDB model. Main results.The original wearable-state model achieved participant-level mean absolute errors (MAEs) of 7.697/6.139 mmHg for systolic/diastolic BP (SBP/DBP). Added context reduced MAE by 0.436/0.126 mmHg (97.5% intervals 0.305-0.573/0.053-0.200). In the matched factorial without the external PPG prior, PPG improved on calibration, time and protocol-provided posture/activity by 0.214/0.135 mmHg; removing time left the DBP interval including zero. Standard PPG descriptors contributed, but additional nonlinear/attractor benefit was not established. In a separate follow-up series, a sensor-history ensemble achieved 7.299/5.445 mmHg versus its static-rich reference's 7.363/5.470, small gains of 0.064/0.025 mmHg. Larger DBP errors did not improve uniformly. Quality-weighted fusion reduced pulse-rate MAE from 3.985 to 3.690 beats per minute. VitalDB MAEs remained 15.375/8.833 mmHg despite small PPG gains. Significance. The contribution is a calibrated evaluation framework with explicit controls, reproducible feature-cache-to-results analyses and retained negative findings. The sensor-history gain is exploratory after repeated dataset reuse. Independently estimated wearable states, complete raw-signal reproduction of the supplied richer features, external transfer and clinical adequacy remain unestablished.

0.24