CS Paper Radar

Personalized and Explainable Blood Pressure Estimation from PPG via Hybrid CNN--Morphological Features

Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim

cs.CV ·submitted 2026-08-11 09:26 UTC · v1
published

Abstract

Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, existing methods have two major limitations. Handcrafted feature-based approaches rely on precise fiducial point detection and are limited to short-term analysis, while deep learning models, despite their accuracy, often operate as black boxes with limited physiological interpretability. To address these challenges, we propose a physiology-guided hybrid framework for personalized BP estimation that couples a convolutional neural network (CNN) branch capturing global and local waveform dynamics with a morphology-prior branch that explicitly encodes person-specific vascular characteristics. By embedding a morphology-based feature set that explicitly encodes individual vascular characteristics, the proposed framework enhances personalization and reduces dependence on large-scale training datasets. Evaluated on a subset of the MIMIC-III database under a subject-specific (personalized) testing protocol, the proposed personalized physiology-guided hybrid approach achieved mean absolute errors (MAEs) of 3.77 mmHg for systolic BP and 2.36 mmHg for diastolic BP, corresponding to relative improvements of 43.7% and 32.4% over a subject-specific (personalized) CNN-only baseline. SHAP-based analysis confirmed that the introduced morphology-prior features align with individual vascular characteristics, reinforcing per-subject interpretability. These findings highlight the potential of personalized, physiology-guided hybrid learning with novel morphological descriptors for accurate and explainable BP monitoring in real-world settings.

DOI
10.1109/ACCESS.2026.3658724

Closest papers

Nearest neighbours by meaning across the whole index.

ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG

cs.LG ·2026-09-28 ·Amir Arjomand, Kenneth B. Kent, Georgiy Krylov
published similarity 0.74
Abstract

Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.

0.21

SIFPBPNet: A Dual-Path Network for Wearable and Cuffless Blood Pressure Estimation via Individualized Steady-state Representation

cs.LG ·2026-09-11 ·Shuailong Tang, Xiaoyu Li, Donglin Xie, Wei Chen, Guangpu Zhu +2 more
published similarity 0.73
Abstract · Accepted for publication at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026), To…

Continuous and cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) is of great interest for low-cost and personalized cardiovascular health management. However, significant population heterogeneity and the "one-to-many mapping" problem, where similar waveforms across individuals correspond to different BP levels, limit the accuracy of conventional population-based models. To address this challenge, we propose a dual-path architecture termed SIFPBPNet, which separately represents steady-state and instantaneous features, through a Steady-state Feature Path (SFP) and an Instantaneous Feature Path (IFP). The SFP employs a Graph Attention Network (GAT) to extract individual-specific and long-term characteristics from multi-day historical PPG trajectories. In parallel, the IFP captures short-term dynamics from current PPG segments and incorporates the steady-state prior via a cross-attention mechanism. Experiments on a large-scale wearable dataset demonstrate that SIFPBPNet achieves a Mean Absolute Error (MAE) of 8.57 and 5.97 mmHg for systolic and diastolic BP, respectively, outperforming state-of-the-art models. Furthermore, the SFP module consistently improves performance when integrated into various backbone architectures, yielding 2.8-13.1% relative MAE reductions for systolic BP. These results highlight the strong generalizability and plug-and-play transferability of the SFP module, underscoring its great potential for accurate cuffless BP monitoring.

0.38

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.71
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.71
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

A Multidimensional Data-Driven Hybrid Transformer Framework for Non-invasive Continuous Blood Pressure Prediction

cs.LG ·2026-08-24 ·Yuexin Ma, Jingqi Hou, Yuxuan Kang, Zhaoying Liu
similarity 0.70
Abstract · 21 pages, 5 figures, 6 tables. Corrected typographical errors in two author email addresses; no changes to the scientific content

Objective. To develop and evaluate a cuffless continuous blood pressure (BP) estimator using temporal physiological and demographic features. We propose a hybrid Transformer framework to estimate diastolic and systolic BP from ECG/PPG-derived feature sequences. Approach. Rather than raw waveforms, the framework models 10-step sequences of six physiological descriptors and two demographic covariates. A Multi-Source Temporal Encoder Module combines Transformer, Kolmogorov-Arnold Network, and XGBoost branches to capture complementary temporal, nonlinear, and tabular information. A Dynamic Conditional Fusion-Decoder applies differential multi-head attention, token-weighted aggregation, and gated residual correction. A robust composite objective jointly optimizes DBP and SBP. Main results. Using the MIMIC-III Waveform and Clinical Databases, the source pool comprised 28,486 waveform segments from 203 subjects, and feature generation retained 53,621 observations from 166 subjects. On 2,431 segment-level held-out test windows, mean error +/- standard deviation was 0.41 +/- 3.74 mmHg for diastolic BP and -1.60 +/- 5.95 mmHg for systolic BP, with 95% limits of agreement of [-6.93, 7.74] and [-13.25, 10.06] mmHg, respectively. The proportions within 10 mmHg were 98.48% and 94.36%. The framework achieved the lowest standard deviations and narrowest limits of agreement among the locally retrained baselines. Significance. The feature-sequence fusion framework improved agreement with reference BP and fell within numerical AAMI and BHS Grade A thresholds on this split. This retrospective analysis is not formal device validation; subject-disjoint and external evaluation remain necessary before clinical use.

0.27

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.69
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.42

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.66
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

Personalized and Adaptive Federated Learning for Canine Cardiomegaly Keypoint Prediction

eess.IV cs.CRcs.CV ·2026-11-13 ·Jialu Li, Youshan Zhang, Honggang Wang
similarity 0.66
Abstract

In the field of medical imaging, limited data and cross-institutional heterogeneity remain major challenges for training robust deep learning models. Federated learning (FL) has emerged as a promising approach that enables collaborative training across institutions while preserving data privacy by keeping datasets local. In this work, we propose a structure-aware personalized and adaptive federated learning framework, PAFL, for automatic vertebral heart score (VHS) estimation and cardiomegaly classification from canine thoracic X-rays. Our method treats the task as anatomical keypoint prediction followed by geometry-based VHS computation, introducing implicit structural consistency and improving interpretability. To address cross-institutional heterogeneity, we adopt a parameter-decomposed architecture that separates shared feature representations from client-specific adaptation modules. Furthermore, we introduce an adaptive, quality-aware aggregation strategy that dynamically weights client contributions based on both dataset size and model quality, thereby enhancing robustness to non-IID data distributions. Experimental results demonstrate that the proposed PAFL framework improves models' predictive performance compared to isolated training and to conventional and existing personalized federated learning (PFL) methods. Our results demonstrate the potential of integrating structure-aware modeling with PFL for reliable and interpretable medical image analysis.

0.13