Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi, Kunio Kashino

cs.LG physics.med-phstat.AP ·submitted 2026-08-26 09:21 UTC · v1

Abstract

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

Comment
8 pages, 5 figures, 2 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Continuous Cuffless Blood Pressure Estimation Using PPG From Methods to Clinical Translation

cs.ET cs.LG ·2026-11-12 ·Karthika Shalini Potail, Harshitha Manjunatha, Hetvi Kotadia, Tooraj Nikoubin
surveybenchmark similarity 0.75
Abstract

Continuous blood pressure (BP) monitoring could improve hypertension management by capturing changes that intermittent cuff measurements miss. Photoplethysmography (PPG) is widely explored for cuffless BP estimation because optical sensors are inexpensive, wearable, and already present in many consumer and clinical devices. PPG, however, does not measure arterial pressure: BP is inferred from waveform characteristics or pulse timing, which also depend on vascular tone, arterial stiffness, sensor contact, motion, and individual physiology. This survey reviews PPG-based cuffless BP estimation along the full measurement chain, covering physiological mechanisms, waveform features, pulse arrival time (PAT), pulse transit time (PTT), machine-learning methods, datasets, calibration, validation, deployment, bias, and clinical translation. Studies are assessed by the strength of evidence they provide rather than by reported error alone, with particular attention to subject and temporal leakage, dataset imbalance, calibration dependence and drift, motion artifacts, and the gap between benchmark accuracy and reliable real-world measurement. The review finds that progress depends on more than better prediction algorithms. Future work should prioritize physiologically informed models, diverse longitudinal datasets, transparent reporting of calibration requirements and failure rates, stronger evaluation protocols, and studies that demonstrate practical value in clinical care.

0.10

ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG

cs.LG ·2026-09-28 ·Amir Arjomand, Kenneth B. Kent, Georgiy Krylov
published similarity 0.67
Abstract

Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.

0.21

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.67
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.66
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

Change Point--Aware Evaluation and Re-Calibration of PPG-Based Blood Pressure Estimation

eess.SP cs.AIcs.LG ·2026-08-19 ·Yunwon Tae, Minje Park, Gyunho Rho, Dongjoon Yoo, Sunghoon Joo
similarity 0.65
Abstract · MLHC 2026. The first two authors contribute equally

Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., $Δ\mathrm{BP} > 10\mathrm{mmHg}$), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.

0.25

Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors

eess.SP ·2026-10-27 ·Elisabetta De Giovanni, Iñigo Urteaga, Matteo Croci, Tomas Teijeiro
publishedbenchmark similarity 0.65
Abstract · Accepted and presented at 53rd Computing in Cardiology conference in Madrid, Spain on 20th - 23rd September 2026

PPG is the main technology for wearable heart rate (HR) monitoring. However, motion artifacts during intense physical activity reduce its reliability due to spectral overlap with the cardiac signal. This study investigates whether severely contaminated PPG signals can yield reliable HR estimates without auxiliary sensors by leveraging prior knowledge of HR dynamics. We acquired simultaneous PPG and ECG signals from 21 subjects during a maximal cycloergometer test. Using Leave-One-Subject-Out cross-validation, we built HR evolution priors from the ground-truth ECG and applied Dynamic Time Warping (DTW) to align normalized HR curves and estimate a barycenter average. DTW aligns normalized HR curves with minimal error across all subjects, validating robust population-based priors. For each test subject, we combined the PPG Power Spectral Density (PSD) with the prior distribution to generate a "posterior PSD". We identified and ranked candidate HR trajectories using heuristic search within the "posterior PSD" and selected the most likely path. Our approach reduced mean absolute error (MAE) in BPM relative to the ground-truth ECG by a median of 63.3% (IQR: 47.3%-74.6%) compared to a PPG+accelerometer benchmark. These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.

0.30

Pulse waveform morphology encodes haemodynamic signatures of impending stroke

cs.AI ·2026-11-07 ·Cheng Ding, Jiaming Liu, Jian Wu, Hongxia Xu, Daoqiang Zhang
similarity 0.64
Abstract · 23 pages, 10 figures

Stroke is a disorder of the circulation, yet the haemodynamic state that immediately precedes it has rarely been observed, because continuous physiological recordings before a stroke are seldom available. Photoplethysmography (PPG), recorded by every pulse oximeter and by hundreds of millions of wearable devices, captures the peripheral pulse beat by beat, but its morphology is largely discarded. Here we ask whether pulse waveform morphology encodes haemodynamic signatures of impending stroke. Using in-hospital stroke as a natural experiment that provides continuous PPG before physician-adjudicated stroke recognition, we studied intensive-care (MIMIC-III, $n=176$) and emergency-department (MC-MED, $n=154$) cohorts and described each beat with interpretable descriptors of pulse timing, amplitude, contour and variability. At a nominal 360-min horizon, morphology separated pre-recognition from stable windows with $F_1$ scores of 0.941 and 0.989 (sensitivity 0.998 and 0.980), with models transferred unchanged to the second cohort, and outperformed heart rate alone on identical windows. The signature was dominated by systolic crest time and its change from each patient's own baseline, feature attribution was concordant across cohorts (Spearman $ρ=0.865$), and morphology recorded in the first two hours of care stratified the subsequent clinical course ($F_1$ 0.714 and 0.691). In high-risk patients without stroke, 29% and 14% of windows were positive, but five-window persistence rules limited alerts to 17% and 2% of patients. The results demonstrate that the routinely recorded pulse thus carries haemodynamic imprint of the period preceding stroke, positioning pulse morphology as a candidate continuous cerebrovascular biomarker.

0.24

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.64
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.43