CS Paper Radar

Robust PPG-Exclusive Heart Rate Estimation During Maximal Exercise Using Population-Based Priors

Elisabetta De Giovanni, Iñigo Urteaga, Matteo Croci, Tomas Teijeiro

eess.SP ·submitted 2026-10-27 12:28 UTC · v1
publishedbenchmark

Abstract

PPG is the main technology for wearable heart rate (HR) monitoring. However, motion artifacts during intense physical activity reduce its reliability due to spectral overlap with the cardiac signal. This study investigates whether severely contaminated PPG signals can yield reliable HR estimates without auxiliary sensors by leveraging prior knowledge of HR dynamics. We acquired simultaneous PPG and ECG signals from 21 subjects during a maximal cycloergometer test. Using Leave-One-Subject-Out cross-validation, we built HR evolution priors from the ground-truth ECG and applied Dynamic Time Warping (DTW) to align normalized HR curves and estimate a barycenter average. DTW aligns normalized HR curves with minimal error across all subjects, validating robust population-based priors. For each test subject, we combined the PPG Power Spectral Density (PSD) with the prior distribution to generate a "posterior PSD". We identified and ranked candidate HR trajectories using heuristic search within the "posterior PSD" and selected the most likely path. Our approach reduced mean absolute error (MAE) in BPM relative to the ground-truth ECG by a median of 63.3% (IQR: 47.3%-74.6%) compared to a PPG+accelerometer benchmark. These results show that physiological priors and DTW-based alignment enable robust, PPG-exclusive HR monitoring during high-intensity exercise.

Comment
Accepted and presented at 53rd Computing in Cardiology conference in Madrid, Spain on 20th - 23rd September 2026

Closest papers

Nearest neighbours by meaning across the whole index.

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.69
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.65
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.65
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.64
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

MoWaveQFormer: A Motion-Conditioned Quality-Gated Transformer for Smartphone-Based PPG Heart Rate Estimation

eess.SP ·2026-09-14 ·Swandip Singha, Rifat Bin Reza, Saifur Rahman Sabuj
similarity 0.63
Abstract · Submitted to arXiv. 8 pages, 5 figures

Photoplethysmography (PPG)-based heart-rate (HR) estimation on smartphones remains unreliable in free-living conditions because motion artifacts vary in spectral structure across activities, and benchmarks such as BUT PPG v2.0 label signal quality only as binary good or bad, discarding partially usable data. This study develops an HR estimation architecture that explicitly conditions motion type and signal quality rather than treating both uniformly. We propose MoWaveQFormer, a three-stage architecture trained under ECG supervision. Stage 1 assigns each window a discrete motion group based on accelerometer-derived spectral energy, without trainable parameters. Stage 2 uses this index to select one of the three learnable FIR filter banks for motion-specific spectral shaping of the PPG signal. Stage 3 embeds the resulting sub-bands into patch tokens, re-weights them via a differentiable soft gate derived from the quality label, and encodes them with a Transformer whose pooled output is regressed to HR, trained jointly with an ECG-supervised loss and a pulse-transit-time consistency term. In a subject-independent split of BUT PPG v2.0 (3,888 recordings, 50 subjects), MoWaveQFormer achieved a mean absolute error of 7.85 bpm, the lowest among five methods, with significant improvements over three baselines (Wilcoxon test, p<0.05). Ablation and Bland-Altman analyses characterize each component's contribution. With 816,445 parameters and sub-3-ms latency, MoWaveQFormer suits real-time deployment, pending validation on smartphone hardware. Replacing motion-agnostic filtering and binary quality discarding with differentiable conditioned processing offers a compact pathway to more reliable free-living PPG-based cardiovascular monitoring.

0.18

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.62
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

ARTA: Graph Combinatorial Optimization for Robust Interbeat Interval Estimation from Wearable Electrocardiogram Signals

eess.SP cs.CLcs.MS ·2026-09-15 ·Shovito Barua Soumma, Asiful Arefeen, Hassan Ghasemzadeh
similarity 0.62
Abstract · Under Review

Accurate heart rate (HR) and interbeat interval (IBI) estimation from wearable electrocardiogram (ECG) is essential for continuous physiological monitoring, but motion artifacts can create false QRS-like peaks and obscure true R-peaks. Conventional detectors and local interval-repair rules process detections independently and may become unreliable when several consecutive beats are corrupted. We present ARTA (Artifact-Robust Temporal Alignment), a graph-based combinatorial framework that estimates the heartbeat sequence through constrained temporal optimization. ARTA combines candidates from multiple ECG detectors, represents them as nodes in a directed acyclic graph and connects candidates through physiologically plausible RR intervals. Candidate confidence uses detector agreement and local ECG quality, while history-dependent transition costs capture recent IBI consistency and a soft heart-rate prior. Beam-search dynamic programming selects a coherent low-cost path across the recording, suppressing false detections and recovering missed beats when plausible auxiliary candidates are available. On the IEEE Signal Processing Cup exercise dataset with electrode-motion artifacts from -2 to 12 dB, ARTA achieved an HR mean absolute error of 1.79 beats per minute, 54% lower than the strongest single-detector baseline, with 92.38% of windows within +/-5 beats per minute, an R-peak F1 score of 0.95, and an IBI mean absolute error of 6.52 ms. Cross-dataset evaluation on the European ST-T Database further assessed transfer to long clinical ambulatory recordings and a label-free reliability analysis examined conditional performance without using reference annotations for segment selection. ARTA is single-channel, training-free, interpretable and computationally lightweight, operating approximately 27 times faster than real time with peak memory below 2.1 MB in a single-thread CPU simulation.

0.17

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.61
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11