CS Paper Radar

Pulse waveform morphology encodes haemodynamic signatures of impending stroke

Cheng Ding, Jiaming Liu, Jian Wu, Hongxia Xu, Daoqiang Zhang

cs.AI ·submitted 2026-11-07 13:53 UTC · v1

Abstract

Stroke is a disorder of the circulation, yet the haemodynamic state that immediately precedes it has rarely been observed, because continuous physiological recordings before a stroke are seldom available. Photoplethysmography (PPG), recorded by every pulse oximeter and by hundreds of millions of wearable devices, captures the peripheral pulse beat by beat, but its morphology is largely discarded. Here we ask whether pulse waveform morphology encodes haemodynamic signatures of impending stroke. Using in-hospital stroke as a natural experiment that provides continuous PPG before physician-adjudicated stroke recognition, we studied intensive-care (MIMIC-III, $n=176$) and emergency-department (MC-MED, $n=154$) cohorts and described each beat with interpretable descriptors of pulse timing, amplitude, contour and variability. At a nominal 360-min horizon, morphology separated pre-recognition from stable windows with $F_1$ scores of 0.941 and 0.989 (sensitivity 0.998 and 0.980), with models transferred unchanged to the second cohort, and outperformed heart rate alone on identical windows. The signature was dominated by systolic crest time and its change from each patient's own baseline, feature attribution was concordant across cohorts (Spearman $ρ=0.865$), and morphology recorded in the first two hours of care stratified the subsequent clinical course ($F_1$ 0.714 and 0.691). In high-risk patients without stroke, 29% and 14% of windows were positive, but five-window persistence rules limited alerts to 17% and 2% of patients. The results demonstrate that the routinely recorded pulse thus carries haemodynamic imprint of the period preceding stroke, positioning pulse morphology as a candidate continuous cerebrovascular biomarker.

Comment
23 pages, 10 figures

Closest papers

Nearest neighbours by meaning across the whole index.

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

cs.LG cs.AI ·2026-11-11 ·Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun +1 more
similarity 0.64
Abstract

Arterial, venous, pulmonary artery and intracranial pressures and ventilator waveforms guide decisions in operating rooms and intensive care units, yet foundation models for physiological waveforms have been built almost entirely on the electrocardiogram and photoplethysmogram. We present CARMEN, a single encoder pretrained without labels on ten cardiorespiratory waveforms (2.27 million modality-hours). CARMEN accepts any combination of co-recorded signals from 10 s to 5 min, and a conditioning mechanism, LSCNorm, restores the absolute signal level that normalization removes; without it, the AUROC for intraoperative hypotension fell from 0.894 to 0.780. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on 12 of 15 and three foundation models, one general-purpose and two for biosignals, on 14 to 17 of 19, with none exceeding it on any task. Given the electrocardiogram or photoplethysmogram alone, it matched or exceeded signal-specific foundation models in most comparisons, and it retained its performance when channels were missing.

0.16

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.64
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

PulseBound: Future-Beat State Forecasting Under an Explicit Information Boundary

cs.AI ·2026-10-08 ·Chenyang Xu, Donglin Xie, Xi Xiang, Xiaoyu Li, Yufan Lu +10 more
similarity 0.63
Abstract · under review

Predictive representation learning from photoplethysmography (PPG) can violate causal information access even with causal attention, as normalization, nonlocal transforms, or companion views may depend on withheld samples. We introduce PulseBound, a PPG representation learner combining physiologically structured future-beat prediction with an explicit stored-window information boundary. A content-independent cutoff separates the visible prefix from the prediction target. Prefix-only normalization, suffix replacement before derived-view construction, and aligned masking ensure that encoder inputs depend only on the visible prefix and cutoff. This yields stored-suffix invariance: with fixed model state, randomness, prefix, and cutoff, changing the stored suffix cannot change the forecast context. A shared horizon-conditioned head predicts nine rhythm and morphology descriptors for up to four extractor-valid future beats, using elementwise validity masks; optional ECG-derived pulse-arrival-time supervision is restricted to training. On MIMIC and VitalDB groups held out from PulseBound backbone pretraining, PulseBound reduces nine-state transformed-space MAE relative to last-visible-beat persistence by 28.06% and 22.22%, respectively, with gains in MAE, MAE-Skill, and Spearman correlation across all 40 source-cutoff-horizon cells. In a separate comparison of seven models on 13 downstream tasks, PulseBound achieves the best mean on nine frozen linear-probe and seven full-fine-tuning tasks. Stored-suffix interventions cause zero recorded changes in forecast contexts or predictions, with zero suffix-input gradients at audited precision under the stored-window interface. These findings separate three testable aspects of predictive physiological representation learning: information access, supervised future structure, and transfer.

0.30

Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI Assessment

eess.SP ·2026-11-09 ·Haowan Wang, Cheng Ding, Donglin Xie, Huizi Yu, Guangkun Nie +3 more
similarity 0.61
Abstract

Access to echocardiography is often limited, delaying recognition of progressive aortic stenosis (AS). A brief, low-cost physiological measurement obtained during routine care could help identify patients who may warrant earlier imaging. Here, we present PulseAS, integrating deep photoplethysmography (PPG) representations, waveform biomarkers and clinical information for high-grade AS screening. Three complementary analyses assessed (1) validation and transfer across cohorts differing in geography and ethnic composition, (2) score-based enrichment of AS and pre-transcatheter aortic valve implantation (TAVI) cases, and (3) preoperative and postoperative pulse changes. Using 15-s recordings, separate patient-level cross-validation in EDU (n = 1,209) and MIMIC-III (n = 2,970) yielded AUROCs of 0.818 (PulseAS-XGB) and 0.838 (PulseAS-L2), respectively. In external validation from MIMIC-III to EDU, PulseAS-XGB achieved an AUROC of 0.716, improving to 0.813 after local adaptation. The highest-scoring 10% captured 45.2% of all high-grade AS cases in EDU and 41.3% in MIMIC-III, and 56.9% of pre-TAVI cases in EDU. Notably, in the EDU TAVI subgroup, PPG waveforms showed earlier systolic peaks and narrower systolic contours following intervention. These findings support clinical-PPG risk stratification in new populations and warrant prospective evaluation of echocardiographic prioritisation.

0.30

When2What: A Timing-Conditioned Framework for Long-Horizon Forecasting of Continuous Cardiovascular Waveforms

cs.LG ·2026-11-06 ·Chaoqi Zhang, Shujie Yan, Zhao Zhang, Yanhua Sun, Yu Wang +4 more
code/data similarity 0.61
Abstract · 31 pages (18 pages main text, 13 pages supplementary material), 7 figures, 31 tables. Code available at https://github.com/prncoprs/when2wha…

Long-horizon forecasting of quasi-periodic cardiovascular waveforms, such as the electrocardiogram (ECG), arterial blood pressure (ABP), and photoplethysmogram (PPG), requires predicting both when future cardiac events will occur (beat timing) and what the local structural pattern looks like around each event (beat morphology). However, standard sequence forecasters trained with pointwise mean squared error (MSE) average across uncertain future heartbeat phases, flattening sharp R peaks and pulse upstrokes into featureless baselines. Our analysis of intraoperative ECG reveals a clear temporal asymmetry: beat-time predictability from history decays within seconds due to stochastic heart-rate variability, whereas local beat morphology aligned at true beat times remains stable over several minutes. Guided by this insight, we introduce When2What, a timing-conditioned framework comprising three stages: Predict, Commit, and Generate. Given a 120-s history, When2What predicts a dense 60-s timing map, selects and sharpens discrete beat events into unit-height Gaussian impulses, and conditions a neural waveform generator on both these committed events and the observed history. Across intraoperative ECG, When2What substantially outperforms existing time-series and physiological forecasters, achieving a near-term waveform event skill of 0.644 and reproducing 95.62% of its predicted heartbeats in the generated waveform where direct long-horizon forecasters collapse into flat baselines. Furthermore, When2What transfers zero-shot to external hospital and atrial fibrillation cohorts, extends effectively to ABP and PPG pulse waveforms, and is supported by ablations and synthetic analyses that establish explicit timing conditioning as an effective paradigm for quasi-periodic long-horizon waveform forecasting.

0.27

ExpertoRhythm: Morphology-Aware Learning for Waveform Reconstruction and Cuffless Blood Pressure Estimation from Single-Channel PPG

cs.LG ·2026-09-28 ·Amir Arjomand, Kenneth B. Kent, Georgiy Krylov
published similarity 0.61
Abstract

Continuous cuffless blood pressure (BP) monitoring from photoplethysmography (PPG) has strong potential for wearable health and telemonitoring, but accurate estimation remains difficult because PPG-to-BP mapping must preserve subtle waveform morphology and pressure-range-dependent dynamics. We introduce ExpertoRhythm, an attention-enhanced 1D U-Net that reconstructs the arterial blood pressure (ABP) waveform from a single-channel PPG signal and derives systolic and diastolic BP directly from the reconstructed waveform. The central contribution is a composite morphology-aware learning objective that integrates range-weighted SmoothL1 reconstruction with a window-range regularizer to emphasize high-dynamic BP segments and reduce amplitude under/over-shoot. On the UCI cuff-less BP dataset with 942 subjects, ExpertoRhythm achieves 2.46/1.46 mmHg MAE for systolic/diastolic BP (SBP/DBP), while obtaining a 30.4% average relative error reduction over pure MSE across waveform reconstruction and BP estimation metrics. Clinical-style evaluation further demonstrates low bias and strong agreement across the BP range, including high-pressure windows up to 200 mmHg, satisfying AAMI criteria and achieving BHS Grade A. These results suggest that morphology-aware waveform reconstruction from a single PPG channel can provide an accurate and practical pathway toward continuous cuffless BP monitoring in wearable and remote-care settings.

0.21

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.60
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.59
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17