CS Paper Radar

Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI Assessment

Haowan Wang, Cheng Ding, Donglin Xie, Huizi Yu, Guangkun Nie, Shenda Hong, Bryan P Yan, Kent Chak-yu So

eess.SP ·submitted 2026-11-09 04:47 UTC · v1

Abstract

Access to echocardiography is often limited, delaying recognition of progressive aortic stenosis (AS). A brief, low-cost physiological measurement obtained during routine care could help identify patients who may warrant earlier imaging. Here, we present PulseAS, integrating deep photoplethysmography (PPG) representations, waveform biomarkers and clinical information for high-grade AS screening. Three complementary analyses assessed (1) validation and transfer across cohorts differing in geography and ethnic composition, (2) score-based enrichment of AS and pre-transcatheter aortic valve implantation (TAVI) cases, and (3) preoperative and postoperative pulse changes. Using 15-s recordings, separate patient-level cross-validation in EDU (n = 1,209) and MIMIC-III (n = 2,970) yielded AUROCs of 0.818 (PulseAS-XGB) and 0.838 (PulseAS-L2), respectively. In external validation from MIMIC-III to EDU, PulseAS-XGB achieved an AUROC of 0.716, improving to 0.813 after local adaptation. The highest-scoring 10% captured 45.2% of all high-grade AS cases in EDU and 41.3% in MIMIC-III, and 56.9% of pre-TAVI cases in EDU. Notably, in the EDU TAVI subgroup, PPG waveforms showed earlier systolic peaks and narrower systolic contours following intervention. These findings support clinical-PPG risk stratification in new populations and warrant prospective evaluation of echocardiographic prioritisation.

Closest papers

Nearest neighbours by meaning across the whole index.

Pulse waveform morphology encodes haemodynamic signatures of impending stroke

cs.AI ·2026-11-07 ·Cheng Ding, Jiaming Liu, Jian Wu, Hongxia Xu, Daoqiang Zhang
similarity 0.61
Abstract · 23 pages, 10 figures

Stroke is a disorder of the circulation, yet the haemodynamic state that immediately precedes it has rarely been observed, because continuous physiological recordings before a stroke are seldom available. Photoplethysmography (PPG), recorded by every pulse oximeter and by hundreds of millions of wearable devices, captures the peripheral pulse beat by beat, but its morphology is largely discarded. Here we ask whether pulse waveform morphology encodes haemodynamic signatures of impending stroke. Using in-hospital stroke as a natural experiment that provides continuous PPG before physician-adjudicated stroke recognition, we studied intensive-care (MIMIC-III, $n=176$) and emergency-department (MC-MED, $n=154$) cohorts and described each beat with interpretable descriptors of pulse timing, amplitude, contour and variability. At a nominal 360-min horizon, morphology separated pre-recognition from stable windows with $F_1$ scores of 0.941 and 0.989 (sensitivity 0.998 and 0.980), with models transferred unchanged to the second cohort, and outperformed heart rate alone on identical windows. The signature was dominated by systolic crest time and its change from each patient's own baseline, feature attribution was concordant across cohorts (Spearman $ρ=0.865$), and morphology recorded in the first two hours of care stratified the subsequent clinical course ($F_1$ 0.714 and 0.691). In high-risk patients without stroke, 29% and 14% of windows were positive, but five-window persistence rules limited alerts to 17% and 2% of patients. The results demonstrate that the routinely recorded pulse thus carries haemodynamic imprint of the period preceding stroke, positioning pulse morphology as a candidate continuous cerebrovascular biomarker.

0.24

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.59
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-27 ·Roy Gabriel, Nattakorn Kittisut, Jamshid Hassanpour, Michael Galarnyk, Abanoub Abdelmalak +4 more
similarity 0.59
Abstract

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

0.46

Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease

cs.CV ·2026-10-21 ·Jinye Li, Qingchao Chen
unusual similarity 0.59
Abstract

Radar heart sounds capture cardiac mechanical activity without contact, while echocardiography characterizes ventricular and valvular function. Paired measurements connect these signals to structural heart disease, yet such data remain sparsely represented in public resources. Here we present 537 radar heart-sound recordings paired with one echocardiographic report for each of 162 patients. The cohort covers three overlapping phenotypes: left ventricular ejection fraction (LVEF) below 50%, regional wall-motion abnormality and at least moderate valvular regurgitation, present in 38, 43 and 39 patients, respectively. Original complex signals, processed radar heart sounds and temporal quality segmentation support signal-to-phenotype analysis. Technical validation retains 95.93% of signal duration and confirms reproducible waveform reconstruction. Patient-level five-fold evaluation achieves a mean outer-test AUROC of $0.770\pm0.138$ for reduced LVEF, identifying mechanical information associated with ventricular systolic dysfunction. This resource supports research linking non-contact cardiac mechanical signals to echocardiographic structural and functional phenotypes.

0.23

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.58
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

Attractor Image-Based Deep Learning of Arterial Pulse Waves for Age Classification

cs.LG ·2026-08-12 ·Sara Vardanega, Patrick Segers, Philip Aston, Ernst Rietzschel, Jordi Alastruey +1 more
published similarity 0.57
Abstract · Accepted at Computing in Cardiology 2025, published in conference proceedings. 8 pages, 2 figures

Arterial pulse waveform morphology evolves with age, reflecting structural and functional changes in the cardiovascular system. Thus, vascular age is a valuable surrogate marker of cardiovascular health, and premature vascular ageing can indicate increased disease risk. Pulse wave analysis could support risk stratification in otherwise asymptomatic adults. We transformed pulse wave time-series data from photoplethysmography (PPG) and arterial tonometry into images, using the Symmetric Projection Attractor Reconstruction (SPAR) method. These SPAR images were used to train a convolutional neural network to classify healthy subjects into two closely spaced age groups (35-40 and 50-55 years). The model demonstrated consistent classification performance across internal and external test sets, achieving F1 scores above 70% for both PPG and tonometry signals. These results suggest that SPAR-derived pulse wave images contain discriminative morphological features even among healthy adults close in age. This proof-of-concept lays the groundwork for future research into the use of SPAR for early risk detection using smart wearables.

0.28

A Vision Transformer for ECG-Based Detection of Left Ventricular Systolic Dysfunction Across Multiple Clinical Sites

cs.CV cs.LG ·2026-08-12 ·Burcu Ozek, Aruna Mohan, David Vorchheimer, Daniel Weiss, Eyal Kedar +3 more
similarity 0.57
Abstract · 19 pages, 5 figures, 5 tables; includes supplementary material with 3 additional figures

Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops. Electrocardiograms are recorded routinely yet underused for this condition, because reduced LVEF has no single diagnostic waveform. We trained an ensemble of vision transformers from scratch to detect reduced LVEF ($\leq$40%) from 12-lead ECGs, analyzing each heartbeat individually, using 10,142 patients across seven sites in three US health systems. In a held-out external cohort of 4,092 patients from three geographically independent US clinical sites at a real-world reduced-LVEF prevalence of 8.72%, the model achieved an AUROC of 0.88 (95% CI 0.86-0.89), sensitivity 81.2%, specificity 81.0%, and negative predictive value 97.8%. Sensitivity remained high across sex, race, ethnicity, and comorbidity subgroups, while specificity was lower in older patients and those with atrial fibrillation or cardiomyopathy. Beat-level attention maps provided interpretability into the model's predictions, showing consistent focus on the QRS complex rather than the P wave. These findings support the potential of routine ECGs as a scalable first-pass triage step to identify patients who should undergo echocardiography for reduced ejection fraction across diverse patient populations.

0.10

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.56
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60