CS Paper Radar

Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease

Jinye Li, Qingchao Chen

cs.CV ·submitted 2026-10-21 06:16 UTC · v1
unusual

Abstract

Radar heart sounds capture cardiac mechanical activity without contact, while echocardiography characterizes ventricular and valvular function. Paired measurements connect these signals to structural heart disease, yet such data remain sparsely represented in public resources. Here we present 537 radar heart-sound recordings paired with one echocardiographic report for each of 162 patients. The cohort covers three overlapping phenotypes: left ventricular ejection fraction (LVEF) below 50%, regional wall-motion abnormality and at least moderate valvular regurgitation, present in 38, 43 and 39 patients, respectively. Original complex signals, processed radar heart sounds and temporal quality segmentation support signal-to-phenotype analysis. Technical validation retains 95.93% of signal duration and confirms reproducible waveform reconstruction. Patient-level five-fold evaluation achieves a mean outer-test AUROC of $0.770\pm0.138$ for reduced LVEF, identifying mechanical information associated with ventricular systolic dysfunction. This resource supports research linking non-contact cardiac mechanical signals to echocardiographic structural and functional phenotypes.

Closest papers

Nearest neighbours by meaning across the whole index.

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.59
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

Integrating Deep PPG Representations and Digital Biomarkers for Aortic Stenosis Detection with Peri-TAVI Assessment

eess.SP ·2026-11-09 ·Haowan Wang, Cheng Ding, Donglin Xie, Huizi Yu, Guangkun Nie +3 more
similarity 0.59
Abstract

Access to echocardiography is often limited, delaying recognition of progressive aortic stenosis (AS). A brief, low-cost physiological measurement obtained during routine care could help identify patients who may warrant earlier imaging. Here, we present PulseAS, integrating deep photoplethysmography (PPG) representations, waveform biomarkers and clinical information for high-grade AS screening. Three complementary analyses assessed (1) validation and transfer across cohorts differing in geography and ethnic composition, (2) score-based enrichment of AS and pre-transcatheter aortic valve implantation (TAVI) cases, and (3) preoperative and postoperative pulse changes. Using 15-s recordings, separate patient-level cross-validation in EDU (n = 1,209) and MIMIC-III (n = 2,970) yielded AUROCs of 0.818 (PulseAS-XGB) and 0.838 (PulseAS-L2), respectively. In external validation from MIMIC-III to EDU, PulseAS-XGB achieved an AUROC of 0.716, improving to 0.813 after local adaptation. The highest-scoring 10% captured 45.2% of all high-grade AS cases in EDU and 41.3% in MIMIC-III, and 56.9% of pre-TAVI cases in EDU. Notably, in the EDU TAVI subgroup, PPG waveforms showed earlier systolic peaks and narrower systolic contours following intervention. These findings support clinical-PPG risk stratification in new populations and warrant prospective evaluation of echocardiographic prioritisation.

0.30

A Vision Transformer for ECG-Based Detection of Left Ventricular Systolic Dysfunction Across Multiple Clinical Sites

cs.CV cs.LG ·2026-08-12 ·Burcu Ozek, Aruna Mohan, David Vorchheimer, Daniel Weiss, Eyal Kedar +3 more
similarity 0.58
Abstract · 19 pages, 5 figures, 5 tables; includes supplementary material with 3 additional figures

Reduced left ventricular ejection fraction (LVEF) is frequently asymptomatic and often detected only after advanced heart failure develops. Electrocardiograms are recorded routinely yet underused for this condition, because reduced LVEF has no single diagnostic waveform. We trained an ensemble of vision transformers from scratch to detect reduced LVEF ($\leq$40%) from 12-lead ECGs, analyzing each heartbeat individually, using 10,142 patients across seven sites in three US health systems. In a held-out external cohort of 4,092 patients from three geographically independent US clinical sites at a real-world reduced-LVEF prevalence of 8.72%, the model achieved an AUROC of 0.88 (95% CI 0.86-0.89), sensitivity 81.2%, specificity 81.0%, and negative predictive value 97.8%. Sensitivity remained high across sex, race, ethnicity, and comorbidity subgroups, while specificity was lower in older patients and those with atrial fibrillation or cardiomyopathy. Beat-level attention maps provided interpretability into the model's predictions, showing consistent focus on the QRS complex rather than the P wave. These findings support the potential of routine ECGs as a scalable first-pass triage step to identify patients who should undergo echocardiography for reduced ejection fraction across diverse patient populations.

0.10

Kapture: Capturing Cardiac Dynamics with Koopman-Governed Learning for Efficient Radar-Based Electrocardiogram Recovery

eess.SP cs.AI ·2026-10-04 ·Tong Wu, Jing Peng, Ziqi Feng, Yuanyuan Zhang
code/data similarity 0.56
Abstract · 5 pages, 3 figures, 2 tables

Millimeter-wave (mmWave) radar enables unobtrusive, contactless electrocardiogram (ECG) reconstruction for cardiac monitoring. Time-frequency spectrograms preserve fine cardiac patterns but often require large backbones to separate ECG-relevant features from respiration, motion, multipath, and subject-dependent interference. We propose Kapture, a parameter-efficient Koopman-governed framework that projects radar hidden states into a low-dimensional observable space and identifies a regularized full linear evolution operator from adjacent observable states. The Koopman-predicted observables refine subsequent hidden states for ECG reconstruction. To suppress predictable interference dynamics, a temporal contrastive objective pulls neighboring states together and separates non-neighbors, while reconstruction supervision preserves task relevance. Using approximately 80 minutes of quasi-static radar-ECG recordings containing realistic noise from body movements and other sources, Kapture consistently improves reconstruction across matched backbone widths, with the largest gains under aggressive compression. The compact configuration approaches the full-width reference accuracy with 68.1% fewer parameters and 91.3% fewer profiler-covered floating-point operations (FLOPs), while the full-width configuration delivers the strongest overall reconstruction performance. Our code will be made publicly available after potential publication.

0.34

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.56
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

Towards Automatic Heart Murmur Characterization from Multi-spot Phonocardiograms

cs.LG cs.SD ·2026-08-26 ·Marcelo Nogueira, Jorge H. Oliveira, Carlos G. Ferreira, Miguel T. Coimbra, Alípio M. Jorge
similarity 0.56
Abstract

Cardiac auscultation traditionally detects the presence of a heart murmur, but clinicians further characterize it by timing, shape, pitch, quality, and grade. Most automatic phonocardiogram analysis systems stop at binary detection and do not estimate this richer description. In this work, we formulate automatic murmur characterization as five patient-level classification tasks and compare three multi-spot strategies on recordings from the aortic, pulmonary, mitral, and tricuspid auscultation locations. First, classical and deep-learning classifiers are trained independently at each location, and predictions are combined via a maximum-severity late-fusion rule. Second, a synchronous multi-input CNN jointly processes one representative segment per location for a single task. Third, a unified multi-input, multi-output CNN predicts all five attributes from one shared multi-spot representation. Using 735 patients from the CirCor DigiScope dataset with complete four-spot recordings, the best late-fusion configurations reach an unweighted mean sensitivity between 85.56% and 93.81% across the five tasks, with class-specific recalls between 80.00% and 100.00% for every relevant category. The multi-input CNN trails late fusion by 7-16 points depending on the task, while the multi-output model reaches values between 72.59% and 79.40%, estimating all five attributes from one shared representation. We further show that naively balancing training data by adding all minority-class segments degrades patient-level performance under the maximum-severity rule, since it introduces non-representative, noisy segments not filtered by the clustering-based segment selection used for evaluation. These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.

0.14

Learning from Scarce Labels: Multi-View Echocardiography for Ejection Fraction Prediction

eess.IV cs.CVcs.LG ·2026-09-02 ·Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafa
top venuedatasetcode/data similarity 0.55
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:025

We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509

0.46

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.55
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37