CS Paper Radar

Towards Automatic Heart Murmur Characterization from Multi-spot Phonocardiograms

Marcelo Nogueira, Jorge H. Oliveira, Carlos G. Ferreira, Miguel T. Coimbra, Alípio M. Jorge

cs.LG cs.SD ·submitted 2026-08-26 09:59 UTC · v1

Abstract

Cardiac auscultation traditionally detects the presence of a heart murmur, but clinicians further characterize it by timing, shape, pitch, quality, and grade. Most automatic phonocardiogram analysis systems stop at binary detection and do not estimate this richer description. In this work, we formulate automatic murmur characterization as five patient-level classification tasks and compare three multi-spot strategies on recordings from the aortic, pulmonary, mitral, and tricuspid auscultation locations. First, classical and deep-learning classifiers are trained independently at each location, and predictions are combined via a maximum-severity late-fusion rule. Second, a synchronous multi-input CNN jointly processes one representative segment per location for a single task. Third, a unified multi-input, multi-output CNN predicts all five attributes from one shared multi-spot representation. Using 735 patients from the CirCor DigiScope dataset with complete four-spot recordings, the best late-fusion configurations reach an unweighted mean sensitivity between 85.56% and 93.81% across the five tasks, with class-specific recalls between 80.00% and 100.00% for every relevant category. The multi-input CNN trails late fusion by 7-16 points depending on the task, while the multi-output model reaches values between 72.59% and 79.40%, estimating all five attributes from one shared representation. We further show that naively balancing training data by adding all minority-class segments degrades patient-level performance under the maximum-severity rule, since it introduces non-representative, noisy segments not filtered by the clustering-based segment selection used for evaluation. These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.

Closest papers

Nearest neighbours by meaning across the whole index.

The Vote Hides the Failure: Aggregation Choice and Noise Robustness in Heart Murmur Detection

cs.LG ·2026-09-29 ·Nicholaus Dismas Ladislaus, Olatunji Damilare Emmanuel, Samuel Chol Buol
published similarity 0.74
Abstract · Workshop Short Paper: GlobalSouthAI @ NeurIPS 2026

Noise robustness in automated phonocardiogram (PCG) murmur detection, and how it is measured, remains underexamined despite growing interest in low-resource screening. We evaluate two independently reimplemented pipelines, Hierarchical Multi-Scale Convolutional Network (HMS-Net)--CNN, and Bidirectional Long Short-Term Memory (BiLSTM)--LSTM, under controlled, multi-severity noise with noise-augmented fine-tuning and held-out generalization testing. Under matched aggregation, the complete BiLSTM pipeline outperforms the complete HMS-Net pipeline across all conditions in accuracy and Weighted Accuracy. A stable aggregate accuracy score can misrepresent what individual predictions show: HMS-Net's native aggregation degrades under salt-and-pepper noise far less than majority-vote (MV) aggregation at the same severity, a gap reflecting window-level disagreement its native rule absorbs, while BiLSTM's MV accuracy rises after noise-augmented training even though its individual predictions do not improve. HMS-Net's training effect is significant under one accuracy metric but not another. Noise-robustness conclusions can depend as much on evaluation choices as on the models themselves.

0.18

Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart Sounds

cs.LG cs.AI ·2026-08-21 ·Marcelo Nogueira, Jorge H. Oliveira, Carlos F. Ferreira, Miguel T. Coimbra, Alípio M. Jorge
similarity 0.71
Abstract

Cardiac auscultation remains the most cost-effective screening procedure for cardiovascular diseases, and requires listening at the four main auscultation spots. Despite this, automatic heart sound analysis algorithms mostly classify patients using a single heart sound (single-channel), or, when using more than one (multi-channel), analyze each channel individually. To our knowledge, no prior work classifies patients through the synchronous analysis of multi-channel heart sounds, following the procedure used by physicians. This motivates us to study whether synchronous multi-channel analysis outperforms single-channel approaches, and whether it holds an advantage over asynchronous multi-channel methods that analyze channels one by one, potentially by capturing inter-channel interference phenomena. To answer these questions, we introduce a selection algorithm that identifies optimal heart sound segments from each of the four auscultation spots, which are then fed into a multi-input CNN that classifies patients by analyzing the four selected sounds simultaneously. Our synchronous approach, combining the proposed selection algorithm with a multi-input CNN, achieves a superior overall accuracy of 96.5\%, a 9.1\% gain over the best-performing single-channel and asynchronous multi-channel methods. The benefit of the proposed segment selection strategy over random selection is confirmed by a paired statistical significance test ($p = 0.003$). These results were obtained on 735 patients from the CirCor DigiScope dataset with complete recordings from all four spots, and their scope and generalizability are discussed in light of this and other methodological considerations.

0.44

AF-Mamba: Efficient Long-Term Signal Modeling for Early Prediction of Atrial Fibrillation Onset

cs.LG ·2026-09-07 ·Yongbin Lee, Ki H. Chon
code/data similarity 0.64
Abstract · 11 pages, 5 figures, 7 tables. Extended version of IEEE BSN 2025. Code: https://github.com/yongbin98/AF_Mamba

Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with increased risks of stroke and heart failure. The growing availability of wearable and portable ECG monitoring enables continuous assessment of cardiac rhythm outside clinical settings. Predicting AF before its onset could provide additional lead time for timely clinical assessment and potentially improve the management of patients at risk of AF-related complications. This study focuses on predicting AF onset one hour in advance using long-term RR intervals (RRIs). To address this challenge, we propose a deep learning architecture that integrates temporal convolutional networks (TCNs) for local features encoding with Mamba, a selective state-space model capable of long-range sequence modeling. This hybrid TCN-Mamba design enables efficient training and inference on one-hour input windows, overcoming limitations of Transformers' quadratic scaling and recurrent networks' vanishing gradients. In subject-wise 5-fold testing, the proposed model achieved a sensitivity of 0.889, specificity of 0.943, F1-score of 0.813, AUROC of 0.974, and AUPRC of 0.933. In paired cross-dataset holdout evaluation, AF-Mamba maintained discriminative performance across unseen AF and NSR datasets, achieving a mean AUROC of 0.897. Compared against state-of-the-art AF prediction models and general time-series models, AF-Mamba achieved competitive predictive performance while providing a favorable performance-efficiency trade-off for long RRI sequences. These findings demonstrate the potential of AF-Mamba for accurate AF prediction one hour in advance and real-time continuous ambulatory monitoring.

0.38

Foundation Model Fine-Tuning with Attention-based Multi-View Fusion for Multi-Task Cardiac Function Assessment

eess.IV cs.AIcs.CV ·2026-11-13 ·João Freitas, Warre Snaet, Jan D'hooge, Sandro Queirós
published similarity 0.62
Abstract · 9 pages, 1 figure. Original pre-peer-review manuscript. Accepted for publication in the MICCAI 2026 Satellite Events (Workshops and Challeng…

In cardio-oncology, left ventricular ejection fraction (LVEF) is the standard biomarker for monitoring cardiac function during cancer therapy. However, its estimation from echocardiography is highly operator dependent, and clinically meaningful declines are often detected only after myocardial injury has progressed, motivating automated methods for standardized assessment and earlier detection of LV dysfunction. To address this need, we propose a multi-task framework integrating cardiac cycle-based temporal standardization, multi-view spatiotemporal feature extraction, and joint optimization for LVEF estimation and LV dysfunction classification. Apical four- and two-chamber echocardiographic sequences are temporally standardized by sampling a clip over an estimated cardiac cycle before being processed by the EchoPrime foundation model, which is fine-tuned end-to-end within the proposed architecture. View-specific features are fused through an attention-based aggregation module to generate a patient-level embedding, from which two task-specific prediction heads estimate continuous LVEF and binary LV dysfunction. To broaden the LVEF distribution encountered during training, samples from the MIMIC-IV-ECHO dataset are incorporated using a balanced sampling strategy. Evaluated on the EchoRisk-MICCAI Challenge, our method achieves an MAE of 4.003 for LVEF estimation (Task 1) and an AUC of 0.764 for LV dysfunction detection (Task 2) on the validation set, demonstrating the effectiveness of foundation model fine-tuning with attention-based multi-view fusion for automated cardiac function assessment in cardio-oncology.

0.37

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.62
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

Enhancing Atrial Fibrillation Detection Through Hyperparameter Optimization

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ilinka Ivanoska, Marjan Gusev
publishedhot direction similarity 0.62
Abstract · 11 pages, 3 figures, 6 tables. Presented at the ICT Innovation 2025 Conference, Ohrid, North Macedonia. Accepted for publish by Springer in …

This study explores the role of hyperparameter optimization (HPO) in enhancing the detection of Atrial Fibrillation (AF) using both machine learning and deep learning models. We evaluated a range of standard classifiers - Decision Tree, Random Forest, and XGBoost classifiers, alongside deep learning architectures including Recurrent Neural Networks, Deep Neural Networks, and Siamese Neural Networks. To fine-tune these models, we applied four HPO methods: Genetic Algorithm, Hyperband, Optuna, and SMAC3. The experiments were conducted using inter-patient and intra- patient data splits to assess model generalization and robustness in the presence of class imbalance, which is reflective of real-world AF occurrence. Our results, based on PhysioNet electrocardiogram datasets, showed that the Hyperband-optimized XGBoost model outperformed all others, achieving a peak F1 score of 96.95%. These findings highlight the critical role of suitable HPO strategies in enhancing the accuracy and robustness of AF classification outcomes in clinical settings.

0.39

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

cs.CV ·2026-11-17 ·Safayet Khan, Hasan Zohirul Islam, Md. Tauhid Bin Iqbal
similarity 0.62
Abstract

Fusion models are usually judged by their fused score, a practice that assumes that every branch has learned something useful. We show that this assumption can fail silently in dual-view heart-sound classification. In AudioFuse, which fuses a spectrogram transformer with a waveform CNN, the spectrogram branch is unused despite strong fused performance when both branches are trained from scratch. We introduce a three-part diagnostic for branch collapse: whether deleting a branch changes the fused score, whether a linear probe on its features beats an untrained copy of the same branch, and whether the branch can learn its view when trained alone. Deleting the branch has negligible effect, and probing its features shows little improvement over an identically initialised, untrained copy. Yet the same architecture trained alone exceeds 0.9 AUC, so its view is learnable, while the jointly trained model is near chance when it must rely on this branch. Update statistics and an initialisation experiment point to an early optimisation imbalance. Moving a strong artificial label cue from one input to the other can switch which branch the model relies on, even though the branch architectures stay the same. We observe branch collapse on PhysioNet, but the full diagnostic is not met on ICBHI or CirCor. Fused performance alone therefore cannot establish that every branch learned a meaningful representation, and we recommend reporting branch deletion and an untrained-control probe alongside it.

0.24

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.61
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13