Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart Sounds

Marcelo Nogueira, Jorge H. Oliveira, Carlos F. Ferreira, Miguel T. Coimbra, Alípio M. Jorge

cs.LG cs.AI ·submitted 2026-08-21 15:38 UTC · v1

Abstract

Cardiac auscultation remains the most cost-effective screening procedure for cardiovascular diseases, and requires listening at the four main auscultation spots. Despite this, automatic heart sound analysis algorithms mostly classify patients using a single heart sound (single-channel), or, when using more than one (multi-channel), analyze each channel individually. To our knowledge, no prior work classifies patients through the synchronous analysis of multi-channel heart sounds, following the procedure used by physicians. This motivates us to study whether synchronous multi-channel analysis outperforms single-channel approaches, and whether it holds an advantage over asynchronous multi-channel methods that analyze channels one by one, potentially by capturing inter-channel interference phenomena. To answer these questions, we introduce a selection algorithm that identifies optimal heart sound segments from each of the four auscultation spots, which are then fed into a multi-input CNN that classifies patients by analyzing the four selected sounds simultaneously. Our synchronous approach, combining the proposed selection algorithm with a multi-input CNN, achieves a superior overall accuracy of 96.5\%, a 9.1\% gain over the best-performing single-channel and asynchronous multi-channel methods. The benefit of the proposed segment selection strategy over random selection is confirmed by a paired statistical significance test ($p = 0.003$). These results were obtained on 735 patients from the CirCor DigiScope dataset with complete recordings from all four spots, and their scope and generalizability are discussed in light of this and other methodological considerations.

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Automatic Heart Murmur Characterization from Multi-spot Phonocardiograms

cs.LG cs.SD ·2026-08-26 ·Marcelo Nogueira, Jorge H. Oliveira, Carlos G. Ferreira, Miguel T. Coimbra, Alípio M. Jorge
similarity 0.71
Abstract

Cardiac auscultation traditionally detects the presence of a heart murmur, but clinicians further characterize it by timing, shape, pitch, quality, and grade. Most automatic phonocardiogram analysis systems stop at binary detection and do not estimate this richer description. In this work, we formulate automatic murmur characterization as five patient-level classification tasks and compare three multi-spot strategies on recordings from the aortic, pulmonary, mitral, and tricuspid auscultation locations. First, classical and deep-learning classifiers are trained independently at each location, and predictions are combined via a maximum-severity late-fusion rule. Second, a synchronous multi-input CNN jointly processes one representative segment per location for a single task. Third, a unified multi-input, multi-output CNN predicts all five attributes from one shared multi-spot representation. Using 735 patients from the CirCor DigiScope dataset with complete four-spot recordings, the best late-fusion configurations reach an unweighted mean sensitivity between 85.56% and 93.81% across the five tasks, with class-specific recalls between 80.00% and 100.00% for every relevant category. The multi-input CNN trails late fusion by 7-16 points depending on the task, while the multi-output model reaches values between 72.59% and 79.40%, estimating all five attributes from one shared representation. We further show that naively balancing training data by adding all minority-class segments degrades patient-level performance under the maximum-severity rule, since it introduces non-representative, noisy segments not filtered by the clustering-based segment selection used for evaluation. These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.

0.14

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

cs.CV ·2026-11-17 ·Safayet Khan, Hasan Zohirul Islam, Md. Tauhid Bin Iqbal
similarity 0.63
Abstract

Fusion models are usually judged by their fused score, a practice that assumes that every branch has learned something useful. We show that this assumption can fail silently in dual-view heart-sound classification. In AudioFuse, which fuses a spectrogram transformer with a waveform CNN, the spectrogram branch is unused despite strong fused performance when both branches are trained from scratch. We introduce a three-part diagnostic for branch collapse: whether deleting a branch changes the fused score, whether a linear probe on its features beats an untrained copy of the same branch, and whether the branch can learn its view when trained alone. Deleting the branch has negligible effect, and probing its features shows little improvement over an identically initialised, untrained copy. Yet the same architecture trained alone exceeds 0.9 AUC, so its view is learnable, while the jointly trained model is near chance when it must rely on this branch. Update statistics and an initialisation experiment point to an early optimisation imbalance. Moving a strong artificial label cue from one input to the other can switch which branch the model relies on, even though the branch architectures stay the same. We observe branch collapse on PhysioNet, but the full diagnostic is not met on ICBHI or CirCor. Fused performance alone therefore cannot establish that every branch learned a meaningful representation, and we recommend reporting branch deletion and an untrained-control probe alongside it.

0.24

The Vote Hides the Failure: Aggregation Choice and Noise Robustness in Heart Murmur Detection

cs.LG ·2026-09-29 ·Nicholaus Dismas Ladislaus, Olatunji Damilare Emmanuel, Samuel Chol Buol
published similarity 0.60
Abstract · Workshop Short Paper: GlobalSouthAI @ NeurIPS 2026

Noise robustness in automated phonocardiogram (PCG) murmur detection, and how it is measured, remains underexamined despite growing interest in low-resource screening. We evaluate two independently reimplemented pipelines, Hierarchical Multi-Scale Convolutional Network (HMS-Net)--CNN, and Bidirectional Long Short-Term Memory (BiLSTM)--LSTM, under controlled, multi-severity noise with noise-augmented fine-tuning and held-out generalization testing. Under matched aggregation, the complete BiLSTM pipeline outperforms the complete HMS-Net pipeline across all conditions in accuracy and Weighted Accuracy. A stable aggregate accuracy score can misrepresent what individual predictions show: HMS-Net's native aggregation degrades under salt-and-pepper noise far less than majority-vote (MV) aggregation at the same severity, a gap reflecting window-level disagreement its native rule absorbs, while BiLSTM's MV accuracy rises after noise-augmented training even though its individual predictions do not improve. HMS-Net's training effect is significant under one accuracy metric but not another. Noise-robustness conclusions can depend as much on evaluation choices as on the models themselves.

0.18

Physiologically Informed Digital Auscultation for Pneumonia Detection in Long-term Care Residents

cs.SD cs.CVcs.LGeess.AS+1 ·2026-09-23 ·Nicholas Rasmussen, Oleg Zaslavsky, Zih-Ling Wang, Hongyu Yu, Joelle Fathi +3 more
similarity 0.58
Abstract · Manuscript has been submitted to NPJ Digital Medicine

Pneumonia is difficult to diagnose in older long-term care residents; multimorbidity and atypical presentations obscure signs, motivating operationally efficient objective testing. We analyzed multi-channel digital stethoscope recordings from 185 Japanese residents (73 pneumonia, 112 symptomatic without), using radiologist-confirmed chest X-rays and clinician diagnoses as supervisory signals that train convolutional neural networks, multimodal fusion, and channel-based variants with time-domain Grad-CAM interpretability. Models were evaluated with repeated patient-level cross-validation showing models with X-ray supervision outperformed clinician supervision (F1 0.729, accuracy 0.783 vs. F1 0.637, accuracy 0.711). Additionally, a three-channel selection protocol maintained performance (F1 0.736; accuracy 0.803), with two mid-thoracic sites ranking highest and Grad-CAM attention overlapping adventitious sounds. These findings indicate automated multi-channel lung-sound analysis can aid long-term care pneumonia diagnosis, with X-ray supervision being more reliable than clinical, and fewer channels preserving performance while lowering acquisition times.

0.14

A New AFIB Detection Method with Deep Neural Networks

cs.LG ·2026-10-29 ·Sara Gjorgjieva, Ana Angjelevska, Dimitar Trajanov, Marjan Gusev
benchmarkhot direction similarity 0.55
Abstract · 10 pages, 7 tables, 3 formulas

Early detection of atrial fibrillation (AFIB), characterized by irregular heart rhythms, can potentially save thousands of lives annually [20]. Numerous studies have attempted to address this challenge using various algorithms and methodologies. This paper introduces a novel and robust method that enhances the precision of AFIB detection. Neural Networks (NN) are widely recognized for their ability to identify complex electrocardiogram (ECG) patterns, facilitating the accurate detection of irregular heart rhythms. This study explores multiple conventional machine learning algorithms alongside neural network approaches to develop a robust AFIB detection system. To evaluate the effective- ness and robustness of the proposed method, the MIT BIH arrhythmia database (MITDB) and the Long-term Atrial Fibrillation Database (LTAFDB), both available on the Physionet site. Our approach presents a novel feature engineering technique, employing specific features such as a time series of the differences in successive heart rates (dBPM) rather than traditional inter-beat intervals. The model analyzes inputs labeled into five distinct classes, using only clean intervals identified through a new labeling method for training while treating others as outliers. This strategy ensures a more accurate and reliable AFIB detection process. The best-performing model, a Deep Neural Network (DNN), achieved an F1 score of 95.18% for binary atrial fibrillation classification on a benchmark dataset distinct from the training set. Models trained using our approach have demonstrated superior performance than previously published models.

0.47

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.54
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification

cs.SD cs.LG ·2026-11-18 ·Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana Yasmin
similarity 0.54
Abstract · 22 pages. Manuscript to be submitted to Biomedical Signal Processing and Control

Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.

0.17

Sensor-Free Shockable Rhythm Classification During CPR Using the Existing ECG Channel of Public-Access Automated External Defibrillators

eess.SP ·2026-11-19 ·Jaechan Lim, David Hicks, Matt Valentine, Ki H. Chon
similarity 0.53
Abstract

Automated external defibrillators (AEDs) are public-access devices intended for use by lay rescuers, yet they must pause chest compressions to analyze the rhythm because compressions corrupt the electrocardiogram (ECG). Removing this pause requires a method that uses the hardware already present in the device, fits within its processor budget, and meets the rhythm-recognition performance required for defibrillator approval. Existing approaches rely either on an auxiliary sensor, which entails a hardware redesign, or on an additional network that reconstructs the ECG before classification. This work classifies the compression-contaminated ECG directly, using only the existing ECG channel of the AED. A cascade of three compact convolutional networks trained with different class ratios verifies each decision with a second network biased toward the proposed outcome; disagreement yields an indeterminate outcome. Evaluated on an independent manufacturer-provided cohort of 464 subjects over 15 train-validation partitions, the cascade satisfies both adjudicable American Heart Association criteria under all six noise conditions at an eight-second window and a signal-to-artifact ratio of 0 dB, with sinus-rhythm specificity of 99.20-99.43% and other non-shockable specificity of 95.48-96.20%, leaving only 1.07-1.48% of segments indeterminate. The criteria are not met at -3 dB. Single networks matched in parameter count and inference cost do not reproduce this performance. Each decision evaluates two of the three networks and requires 6.68 ms on a single thread of a general-purpose processor, and eight-bit quantization reduces the model to 1.45 MiB without changing any compliance verdict. Thus, rhythm analysis during ongoing CPR can be implemented with the ECG hardware already present in public-access AEDs, without auxiliary sensing hardware, subject to validation on the target device.

0.17