CS Paper Radar

RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification

Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana Yasmin

cs.SD cs.LG ·submitted 2026-11-18 12:26 UTC · v1

Abstract

Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.

Comment
22 pages. Manuscript to be submitted to Biomedical Signal Processing and Control

Closest papers

Nearest neighbours by meaning across the whole index.

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.74
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

RespFocus: Learning Temporal Evidence for Weakly Supervised Respiratory Sound Classification

cs.LG cs.AI ·2026-10-11 ·Yi Tian, Xiaohuan Chen, Yufei tang, Xinyu Lin, Hongliang Li +3 more
similarity 0.68
Abstract · 9 pages, 5 figures,2 tables

Respiratory auscultation provides a low-cost means of assessing pulmonary function, yet transient crackles and sustained wheezes can be difficult to recognize in noisy clinical recordings. Conventional deep learning classifiers often operate as black boxes, offering limited insight into the temporal acoustic evidence supporting their predictions. We present RespFocus, a weakly supervised framework that uses multiple instance learning (MIL) to learn inspectable temporal evidence from cycle-level labels and integrate it into classification. We also introduce PedResp2026, a multicenter pediatric respiratory sound cohort collected in routine clinical environments with adjudicated cycle-level annotations. In classification experiments, RespFocus achieves four-class Scores of 69.55\% on public ICBHI 2017 and 72.91\% on PedResp2026. Evidence diagnostics and matched temporal interventions support the functional contribution of the learned evidence to model predictions. Together, these findings highlight RespFocus's potential as a tool for automated respiratory sound diagnosis.

0.30

Metadata-Conditioned Audio Transformers for Adaptive Respiratory Sound Classification

cs.SD cs.AIeess.AS ·2026-11-02 ·George Kontogiannis, Pantelis Tzamalis, Sotiris Nikoletseas
publishedbenchmark similarity 0.65
Abstract

Respiratory sound classification from auscultation recordings is confounded by heterogeneous acquisition conditions, including recording device, auscultation site, and patient characteristics, that introduce systematic variability unrelated to the underlying pathology. Although such metadata is often available, existing approaches either ignore it or rely on naïve fusion strategies that do not model how distinct metadata sources influence different components of the acoustic representation. We propose a family of metadata-conditioning mechanisms for the Audio Spectrogram Transformer (AST), progressing from gated residual fusion to Feature-wise Linear Modulation (FiLM) adapted to the Transformer architecture. We further introduce two novel variants: Token-Aware FiLM (TAFiLM), which applies distinct modulation to classification and patch tokens, and Soft-Factorized FiLM (SoftFiLM), which learns soft masks to align metadata factors with disentangled feature subspaces. Experiments on the ICBHI benchmark demonstrate consistent gains across all conditioning strategies. SoftFiLM achieves 64.11% on the official 4-class task (+3.94% over the baseline) and 72.40% on the 2-class task, establishing a new state-of-the-art on the 2-class task and competitive performance on the 4-class benchmark.

0.24

WIPSNet: Deep Learning for Paediatric Wheeze Detection from Overnight Impedance Pneumography

cs.LG eess.SP ·2026-09-30 ·Felix Oury, Harley Day, Karina Mayoral, Ville-Pekka Seppä, Sejal Saglani +1 more
publishedcode/data similarity 0.63
Abstract · Accepted at the Workshop on Structured Data for Health, ICML 2026. Code: https://github.com/felix-oury/WIPSNet

Overnight impedance pneumography (IP) is used to monitor paediatric respiratory health. Its current clinical readout, the Expiratory Variability Index (EVI), compresses each IP recording into a single scalar and achieves an AUC of 0.633 for night-level wheeze classification. We introduce Wheeze Impedance Pneumography Scalogram Network (WIPSNet), a 3D ResNet operating on stacked continuous wavelet transform scalograms of overnight IP signals. On a 15-patient cohort (60 nights, 281 hours), WIPSNet achieves an AUC of $0.783 \pm 0.026$, outperforming EVI, a state-space model (Mamba), and two modern sleep-staging architectures. Performance peaks at a volumetric depth corresponding to 32 minutes of temporal context, suggesting that multi-scale temporal aggregation is important for modelling nocturnal respiratory dynamics. Overall, these results indicate that structured time-frequency representations combined with 3D convolutional architectures provide an effective approach for learning from long, irregular physiological time series.

0.46

Is a CNN-Transformer Ensemble Worth It When a Chest X-Ray Foundation Model Is Available?

eess.IV cs.CV ·2026-11-09 ·Aditya Seelaboyina, Irfan Khan
code/data similarity 0.63
Abstract · 8 pages, 2 figures, 10 tables. Code: https://github.com/adityaseelaboyina/cxr-ensemble-vs-foundation-model

Ensembles of ImageNet-pretrained convolutional networks and Vision Transformers are a common way to improve multi-label chest X-ray classification. We ask whether such an ensemble is still worth its cost when a model pretrained on chest radiographs is available. On the official patient-disjoint split of NIH ChestX-ray14 (25,596 test images, 2,797 patients), we train five ImageNet-pretrained backbones and the EVA-X-S foundation model with validation-only model selection, compare five fusion rules, and estimate every difference with a patient-level paired bootstrap. EVA-X-S alone reached a test macro-AUROC of 0.828; the five-model ensemble reached 0.814 (difference -0.0136, 95% CI -0.0178 to -0.0098) at about 7.8 times the summed backbone latency and ten times the parameters. Averaging the five ImageNet models with EVA-X-S changed AUROC by -0.0056 (-0.0095 to -0.0021). With all five ImageNet backbones trained with the EVA-X-S recipe, their ensemble scored 0.817, still -0.0109 (-0.0142 to -0.0076) below EVA-X-S, and across three seeds EVA-X-S varied by at most 0.001 AUROC. Under the ImageNet models' recipe, however, EVA-X-S fell to 0.798. Our full-stacking configuration never outperformed calibrated averaging. In this setting, the tested ImageNet ensembles did not improve on a single chest X-ray foundation model fine-tuned with its own recipe.

0.38

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.62
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09

Beyond Accuracy: Quantifying Pulmonary Attribution in Anatomy-Guided Chest X-Ray Classification Under Domain Shift

cs.CV ·2026-08-31 ·Abdullah Al Mamun, Md. Nasif Osman Khansur, Md Ashraful Hossen Akash, Md. Kishor Morol, Tze Hui Liew
code/data similarity 0.62
Abstract · 34 pages, 8 figures, 7 tables. Code available at https://github.com/Abdullah-229/BeyondAccuracy

Deep-learning models can achieve strong chest X-ray (CXR) classification performance without establishing whether their predictions predominantly rely on pulmonary image content. This study evaluates pulmonary attribution containment as an anatomy-related reliability property distinct from diagnostic performance. We propose DBCA-SegNet-MGAP, a multi-task anatomy-guided CNN-Transformer framework that combines complementary feature representations through bidirectional cross-backbone attention, predicts a soft lung mask, and incorporates this anatomical prior directly into classification through Mask-Guided Adaptive Global Average Pooling (MGAP). Pulmonary attribution containment is quantified using the Anatomical Local Energy Ratio (ALR) and high-intensity cumulative ALR (cALR@0.9). Experiments were repeated across three training seeds using the COVID-19 Radiography Database for four-class internal testing and a locked Shenzhen-to-Montgomery protocol for zero-shot external tuberculosis testing. On COVID-19, the proposed model achieved a weighted F1 of $0.9615 \pm 0.0015$ and macro ROC-AUC of $0.9906 \pm 0.0007$. In an architecture-matched dual-bridge comparison, replacing conventional GAP with MGAP increased ALR from $0.3878 \pm 0.0098$ to $0.7086 \pm 0.0104$ and cALR@0.9 from $0.5265 \pm 0.0101$ to $0.9905 \pm 0.0018$, while weighted F1 remained essentially unchanged ($0.9618 \pm 0.0015$ vs. $0.9615 \pm 0.0015$). Under locked external transfer to Montgomery, ROC-AUC remained $0.9080 \pm 0.0043$ and pulmonary ALR remained $0.6466 \pm 0.0081$, whereas weighted F1 decreased to $0.7528 \pm 0.0080$ and ECE increased to $0.1683 \pm 0.0055$. These findings show that diagnostic discrimination, calibration, and pulmonary attribution containment are distinct model properties and support their joint evaluation under internal testing and external domain shift.

0.52

Clinically Informed Acoustic-Aware Attribute Modeling for Respiratory Sound Classification

cs.SD ·2026-10-16 ·Xinhong Li, Li Xiao, Ziyang Chen, Yuhong Yang, Weiping Tu
similarity 0.62
Abstract · Accecpted by BIBM2026 regular paper

Automated respiratory sound classification (RSC) aims to identify normal and adventitious respiratory sounds, such as crackles and wheezes. Most existing methods formulate RSC as a flat four-class classification problem over norma, crackle, wheeze and both. However, unlike conventional classification tasks with semantically independent and mutually exclusive categories, the commonly used four-class RSC labels have a compositional structure and can be represented by two clinically meaningful sound attributes: crackle presence and wheeze presence. Existing flat classifiers do not explicitly exploit this structure, which may increase the learning burden by treating the four labels as independent targets. Meanwhile, crackles and wheezes exhibit distinct temporal characteristics, with sparse transient crackle events and sustained continuous wheeze patterns, making a single temporal aggregation strategy less suitable for modeling different adventitious sound evidence. To address these limitations, we propose an Acoustic-Aware Asymmetric Framework (AAAF) for RSC. AAAF reformulates four-class recognition as two sound-attribute detection tasks and recovers the final category through logical composition during inference. Built upon a pretrained BEATs encoder, AAAF employs branch-specific multi-layer fusion and asymmetric temporal aggregation to capture localized crackle evidence and sustained wheeze patterns. Auxiliary normal--abnormal supervision and a batch-adaptive dynamic loss are further introduced to improve global discrimination and robustness under imbalanced labels. Experiments on ICBHI and SPRSound demonstrate that AAAF improves overall RSC performance and generalizes across datasets, achieving a state-of-the-art four-class Score of 65.30% on ICBHI.

0.24