CS Paper Radar

The Vote Hides the Failure: Aggregation Choice and Noise Robustness in Heart Murmur Detection

Nicholaus Dismas Ladislaus, Olatunji Damilare Emmanuel, Samuel Chol Buol

cs.LG ·submitted 2026-09-29 09:52 UTC · v2
published

Abstract

Noise robustness in automated phonocardiogram (PCG) murmur detection, and how it is measured, remains underexamined despite growing interest in low-resource screening. We evaluate two independently reimplemented pipelines, Hierarchical Multi-Scale Convolutional Network (HMS-Net)--CNN, and Bidirectional Long Short-Term Memory (BiLSTM)--LSTM, under controlled, multi-severity noise with noise-augmented fine-tuning and held-out generalization testing. Under matched aggregation, the complete BiLSTM pipeline outperforms the complete HMS-Net pipeline across all conditions in accuracy and Weighted Accuracy. A stable aggregate accuracy score can misrepresent what individual predictions show: HMS-Net's native aggregation degrades under salt-and-pepper noise far less than majority-vote (MV) aggregation at the same severity, a gap reflecting window-level disagreement its native rule absorbs, while BiLSTM's MV accuracy rises after noise-augmented training even though its individual predictions do not improve. HMS-Net's training effect is significant under one accuracy metric but not another. Noise-robustness conclusions can depend as much on evaluation choices as on the models themselves.

Comment
Workshop Short Paper: GlobalSouthAI @ NeurIPS 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Towards Automatic Heart Murmur Characterization from Multi-spot Phonocardiograms

cs.LG cs.SD ·2026-08-26 ·Marcelo Nogueira, Jorge H. Oliveira, Carlos G. Ferreira, Miguel T. Coimbra, Alípio M. Jorge
similarity 0.74
Abstract

Cardiac auscultation traditionally detects the presence of a heart murmur, but clinicians further characterize it by timing, shape, pitch, quality, and grade. Most automatic phonocardiogram analysis systems stop at binary detection and do not estimate this richer description. In this work, we formulate automatic murmur characterization as five patient-level classification tasks and compare three multi-spot strategies on recordings from the aortic, pulmonary, mitral, and tricuspid auscultation locations. First, classical and deep-learning classifiers are trained independently at each location, and predictions are combined via a maximum-severity late-fusion rule. Second, a synchronous multi-input CNN jointly processes one representative segment per location for a single task. Third, a unified multi-input, multi-output CNN predicts all five attributes from one shared multi-spot representation. Using 735 patients from the CirCor DigiScope dataset with complete four-spot recordings, the best late-fusion configurations reach an unweighted mean sensitivity between 85.56% and 93.81% across the five tasks, with class-specific recalls between 80.00% and 100.00% for every relevant category. The multi-input CNN trails late fusion by 7-16 points depending on the task, while the multi-output model reaches values between 72.59% and 79.40%, estimating all five attributes from one shared representation. We further show that naively balancing training data by adding all minority-class segments degrades patient-level performance under the maximum-severity rule, since it introduces non-representative, noisy segments not filtered by the clustering-based segment selection used for evaluation. These results indicate multi-spot murmur characterization is feasible with both fusion-based and jointly learned architectures, outlining a path toward automatic, structured murmur reports complementing binary screening.

0.14

Feature Scaling Beats Architecture Choice in Offline Respiratory Screening for Low-Resource Clinics

cs.LG cs.AIcs.SD ·2026-10-12 ·Abubakar Chilala, Cleophas Kadima, Innocent Anyaele, Victor Olufemi
similarity 0.62
Abstract

Deep models are the usual choice for respiratory sound classification, but in clinics without GPUs or connectivity that choice carries a cost. We compare classical and deep classifiers on a five-class respiratory-sound corpus of 1,211 clips (asthma, COPD, pneumonia, Bronchial, healthy) from 201 patient groups, with a 3.86:1 class imbalance, using pre-registered patient-grouped cross-validation (25 runs per configuration). An SVM over 30 summary features (MFCC, ZCR and RMS statistics) reaches macro recall 0.78 and 0.71 recall on the rarest class. A 1.13M-parameter convolutional recurrent network over log-Mel spectrograms reaches 0.75 to 0.77, and no difference between model families is resolved. The largest single effect we measure is a preprocessing effect rather than an architectural one. Standardizing the SVM's features, a routine step for RBF kernels, moves its macro recall from 0.51 to 0.78, a 27-point swing wider than any gap between model families here. Augmentation did not help: SMOTE, waveform augmentation and SpecAugment have no measurable effect. Latency does not separate the models (51 to 74 ms per clip on a CPU-only laptop), but the classical models avoid a 449 MB PyTorch runtime. Clip-level splits, which let a patient's recordings fall on both sides, inflate macro recall by 7.5 to 9.8 points. Recording source is strongly tied to label (Cramer's V = 0.65 between native sampling rate and class), and in an exploratory analysis clips recorded at a class's minority rate are mostly assigned to classes typical of that rate; we state this confound as the paper's main limitation.

0.13

Selection of Heart Sound Segments for Synchronous Classification of Multi-channel Heart Sounds

cs.LG cs.AI ·2026-08-21 ·Marcelo Nogueira, Jorge H. Oliveira, Carlos F. Ferreira, Miguel T. Coimbra, Alípio M. Jorge
similarity 0.60
Abstract

Cardiac auscultation remains the most cost-effective screening procedure for cardiovascular diseases, and requires listening at the four main auscultation spots. Despite this, automatic heart sound analysis algorithms mostly classify patients using a single heart sound (single-channel), or, when using more than one (multi-channel), analyze each channel individually. To our knowledge, no prior work classifies patients through the synchronous analysis of multi-channel heart sounds, following the procedure used by physicians. This motivates us to study whether synchronous multi-channel analysis outperforms single-channel approaches, and whether it holds an advantage over asynchronous multi-channel methods that analyze channels one by one, potentially by capturing inter-channel interference phenomena. To answer these questions, we introduce a selection algorithm that identifies optimal heart sound segments from each of the four auscultation spots, which are then fed into a multi-input CNN that classifies patients by analyzing the four selected sounds simultaneously. Our synchronous approach, combining the proposed selection algorithm with a multi-input CNN, achieves a superior overall accuracy of 96.5\%, a 9.1\% gain over the best-performing single-channel and asynchronous multi-channel methods. The benefit of the proposed segment selection strategy over random selection is confirmed by a paired statistical significance test ($p = 0.003$). These results were obtained on 735 patients from the CirCor DigiScope dataset with complete recordings from all four spots, and their scope and generalizability are discussed in light of this and other methodological considerations.

0.44

Strong Fused Performance Can Mask Branch Collapse in a Dual-View Heart-Sound Classifier: A Three-Part Diagnostic Protocol

cs.CV ·2026-11-17 ·Safayet Khan, Hasan Zohirul Islam, Md. Tauhid Bin Iqbal
similarity 0.59
Abstract

Fusion models are usually judged by their fused score, a practice that assumes that every branch has learned something useful. We show that this assumption can fail silently in dual-view heart-sound classification. In AudioFuse, which fuses a spectrogram transformer with a waveform CNN, the spectrogram branch is unused despite strong fused performance when both branches are trained from scratch. We introduce a three-part diagnostic for branch collapse: whether deleting a branch changes the fused score, whether a linear probe on its features beats an untrained copy of the same branch, and whether the branch can learn its view when trained alone. Deleting the branch has negligible effect, and probing its features shows little improvement over an identically initialised, untrained copy. Yet the same architecture trained alone exceeds 0.9 AUC, so its view is learnable, while the jointly trained model is near chance when it must rely on this branch. Update statistics and an initialisation experiment point to an early optimisation imbalance. Moving a strong artificial label cue from one input to the other can switch which branch the model relies on, even though the branch architectures stay the same. We observe branch collapse on PhysioNet, but the full diagnostic is not met on ICBHI or CirCor. Fused performance alone therefore cannot establish that every branch learned a meaningful representation, and we recommend reporting branch deletion and an untrained-control probe alongside it.

0.24

DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series Denoising

cs.LG cs.AI ·2026-09-28 ·Basile Morel, Samuel Ruiperez-Campillo, Andreas P. Streich, Julia E. Vogt, Thomas Hofmann
similarity 0.58
Abstract · First three authors are co-first. Last two authors are co-last

Electrocardiogram (ECG) recordings are corrupted by non-stationary noise sources that degrade diagnostic reliability, particularly in ambulatory and long-duration recordings. Deep learning denoisers exist, but convolutional architectures are limited by their receptive field, transformer-based models scale quadratically with sequence length, and diffusion-based approaches incur prohibitive inference cost. We propose a Mamba-augmented model that inserts selective state-space blocks at the convolutional bottleneck, combining local feature extraction with long-range temporal modeling at linear complexity. We comprehensively evaluate the proposed model with respect to reconstruction fidelity, noise robustness, recording-length scaling, and downstream diagnostic classification across over 40 pathology classes. On synthetic and real datasets, our model achieves the highest SNR and lowest RMSE, with the Mamba advantage increasing with sequence length and in low-SNR regimes. On classification with two independent classifiers, the proposed Mamba-based models achieve the best macro AUROC among all denoisers and improve over their convolutional base models. Calibration is more nuanced and classifier-dependent: denoising improves Binary Cross-Entropy and Brier score on Inception1D but often fails to beat the noisy input on ResNet1D-Wang, and the lead-specific Mamba variant is the only denoiser to improve both calibration metrics over the noisy baseline on both classifiers. Per-class analysis reveals a morphology-dependent benefit: Mamba substantially improves ST/T-change diagnoses, which depend on broad, context-sensitive waveforms.

0.07

Towards Deployable Underwater Vessel Classification

cs.SD cs.LG ·2026-09-24 ·Abishek Soti, Thura Pyae Sone, Naqib Ibnul, Htoo Htet Aung, Henry Zhong +2 more
similarity 0.57
Abstract

We propose a compact underwater acoustic classification framework combining multi-representation feature engineering, temporal statistical pooling, and compact convolutional architectures designed for acoustic time-frequency and cochlear representations. We investigate multiple conventional and auditory-inspired representations and first evaluate lightweight classifiers and Conventional Neural Networks (CNNs) on ShipsEar dataset. On the provided split, a two-layer CNN achieves a macro F1 of 0.9918, while a Radial Basis Function Support Vector Machine (RBF-SVM) reaches 0.9883. However, source-recording provenance cannot be reconstructed, preventing verification of recording-independent generalisation. We therefore evaluate on DeepShip dataset using recording-level partitioning before segmentation. Under this protocol, a 157K-parameter compact CNN achieves a test macro F1 of 0.7226, while an 11.17M-parameter ResNet18 provides no improvement in validation performance under the matched setting. These results demonstrate the importance of representation-aware feature and model design, together with rigorous recording-level evaluation, for classification performance and deployability in compact underwater acoustic systems.

0.26

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
similarity 0.57
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28

Scalable Audio-LLM System for Speech MOS Evaluation: A Diagnostic Case Study and Adaptation Roadmap

cs.SD eess.AS ·2026-10-30 ·Dimitrios Kokkinis, Panagiotis Kakoulidis, Nikolaos Ellinas, Chrysovalanti Lymperi, Alexandra Vioni +8 more
benchmark similarity 0.57
Abstract

The continuous deployment of enterprise voice systems creates a critical operational bottleneck: evaluating the acoustic quality of synthetic speech across high-volume production updates. While human Mean Opinion Score (MOS) remains the quality gold standard, it introduces severe operational costs and turn-around delays that make continuous integration infeasible. In this work, we present a system design case study for a scalable, low-cost and offline evaluation pipeline capable of scoring large batches of synthetic speech at marginal cost. First, we use Qwen2-Audio-7B-Instruct in a zero-shot setting for granular MOS estimation, noticing perceptual blind spots and inherent biases. Then, we analyze SOMOS dataset and construct a diagnostic benchmark that operationalizes two prosodic dimensions associated with human naturalness ratings. Finally, we adapt Qwen2-Audio-7B-Instruct through a parameter-efficient finetuning (LoRA) on the task of MOS evaluation, observing improvements over base model and widely used neural baselines like UTMOS and establishing a practical blueprint for enterprise-grade speech quality assurance.

0.11