A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang, Canhua Xu, Fugui Qi

cs.AR eess.SPeess.SY ·submitted 2026-11-05 02:50 UTC · v1

Abstract

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

Comment
11 pages, 9 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Kapture: Capturing Cardiac Dynamics with Koopman-Governed Learning for Efficient Radar-Based Electrocardiogram Recovery

eess.SP cs.AI ·2026-10-04 ·Tong Wu, Jing Peng, Ziqi Feng, Yuanyuan Zhang
code/data similarity 0.66
Abstract · 5 pages, 3 figures, 2 tables

Millimeter-wave (mmWave) radar enables unobtrusive, contactless electrocardiogram (ECG) reconstruction for cardiac monitoring. Time-frequency spectrograms preserve fine cardiac patterns but often require large backbones to separate ECG-relevant features from respiration, motion, multipath, and subject-dependent interference. We propose Kapture, a parameter-efficient Koopman-governed framework that projects radar hidden states into a low-dimensional observable space and identifies a regularized full linear evolution operator from adjacent observable states. The Koopman-predicted observables refine subsequent hidden states for ECG reconstruction. To suppress predictable interference dynamics, a temporal contrastive objective pulls neighboring states together and separates non-neighbors, while reconstruction supervision preserves task relevance. Using approximately 80 minutes of quasi-static radar-ECG recordings containing realistic noise from body movements and other sources, Kapture consistently improves reconstruction across matched backbone widths, with the largest gains under aggressive compression. The compact configuration approaches the full-width reference accuracy with 68.1% fewer parameters and 91.3% fewer profiler-covered floating-point operations (FLOPs), while the full-width configuration delivers the strongest overall reconstruction performance. Our code will be made publicly available after potential publication.

0.34

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.61
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.60
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18

Clinical radar heart sounds with echocardiographic phenotypes of ventricular dysfunction and valvular disease

cs.CV ·2026-10-21 ·Jinye Li, Qingchao Chen
unusual similarity 0.59
Abstract

Radar heart sounds capture cardiac mechanical activity without contact, while echocardiography characterizes ventricular and valvular function. Paired measurements connect these signals to structural heart disease, yet such data remain sparsely represented in public resources. Here we present 537 radar heart-sound recordings paired with one echocardiographic report for each of 162 patients. The cohort covers three overlapping phenotypes: left ventricular ejection fraction (LVEF) below 50%, regional wall-motion abnormality and at least moderate valvular regurgitation, present in 38, 43 and 39 patients, respectively. Original complex signals, processed radar heart sounds and temporal quality segmentation support signal-to-phenotype analysis. Technical validation retains 95.93% of signal duration and confirms reproducible waveform reconstruction. Patient-level five-fold evaluation achieves a mean outer-test AUROC of $0.770\pm0.138$ for reduced LVEF, identifying mechanical information associated with ventricular systolic dysfunction. This resource supports research linking non-contact cardiac mechanical signals to echocardiographic structural and functional phenotypes.

0.23

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.58
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.58
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

cs.HC ·2026-09-21 ·Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl
published similarity 0.57
Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

0.38

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.57
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.43