CS Paper Radar

Beyond Contact Sensors: Deep learning with Pseudo-Labeling for remote Photoplethysmography

Bhargav Acharya, Barbara Hammer, Hanna Drimalla

cs.LG ·submitted 2026-09-09 11:00 UTC · v1

Abstract

Heart rate is a critical biomarker of health, and remote photoplethysmography (rPPG) enables its contactless estimation from video data for telemedicine applications. Recent advancements in deep learning based rPPG methods achieve state-of-the-art results, outperforming classical signal-processing methods in complex scenarios. However, deep learning methods depend on datasets with precise synchronization between videos and ground truth signals collected via contact sensors, whereas signal-processing-based methods do not. To address this dependence on labeled datasets, which are labor-intensive to collect, we investigate under which circumstances pseudo-labels extracted using unsupervised signal-processing methods can replace contact sensors labels for training deep learning methods. Our systematic evaluations found that for datasets with imperfect synchronization, the pseudo-label approach outperforms supervised training on contact sensors. For datasets with good synchronization, results are mixed: within-dataset evaluation shows no significant difference between training methods, while cross-dataset evaluation favors supervised training. However, removing a single outlier participant significantly improves the pseudo-label approach's cross-dataset performance, highlighting the importance of label quality. These results demonstrate that signal-processing methods can generate valid training signals for deep learning models, reducing dependency on labor-intensive dataset collection while maintaining competitive performance.

Closest papers

Nearest neighbours by meaning across the whole index.

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

cs.LG cs.AIcs.CVeess.SP ·2026-10-06 ·Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim +4 more
benchmarkcode/data similarity 0.63
Abstract · 20 pages, 5 figures. First two authors contributed equally

Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

0.30

Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing

cs.LG cs.ET ·2026-09-26 ·Constantino Álvarez Casado, Nhi Nguyen, Mohammad Rakibur Rahman, Le Nguyen, Manuel Lage Cañellas +2 more
similarity 0.63
Abstract · 9 pages, 4 figures, 7 tables, 24 numbered equations. Extended version of a conference submission, with additional methodological details, im…

Millimeter-wave (mmWave) radar and RGB-D cameras can record cardiac and respiratory waveforms continuously and without contact, but labeled recordings remain scarce because every label requires a supervised acquisition session. Self-supervised pretraining can exploit the unlabeled signals, yet contrastive methods depend on signal transformations and negative pairs whose validity is uncertain for cardiorespiratory data, where time warping changes breathing rate and distant windows can share the same physiological state. We present Phenomenon-Graph JEPA, a joint-embedding predictive architecture that learns from four processed one-dimensional streams without negative pairs or synthetic augmentation in its base configuration. Each stream is encoded by a temporal convolutional branch and a band-limited spectral branch. During pretraining, the model predicts stopped target embeddings along typed edges, which connect streams assigned to the same physiological phenomenon, and forward in time within a state episode. We treat this physiological typing as a testable hypothesis and compare it with wrong-edge and all-pairs prediction graphs. In the OMuSense-23 dataset, pretraining improves label-efficiency area over matched supervised training by 3.91 percentage points (95% interval 2.08 to 5.80, Holm-adjusted p = 0.006), and by 3.74 points under a second configuration evaluated on the same test participants. However, the wrong-edge and all-pairs controls do not establish a benefit from physiological typing. Optional Takens-inspired delay coordinates improve a validation comparison with learned history, whereas two wrist-only WESAD protocols do not establish a pretraining advantage. The study therefore separates the measured benefit of predictive representations from the physiological prior used to organize their training.

0.20

Personalized and Explainable Blood Pressure Estimation from PPG via Hybrid CNN--Morphological Features

cs.CV ·2026-08-11 ·Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
published similarity 0.62
Abstract

Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, existing methods have two major limitations. Handcrafted feature-based approaches rely on precise fiducial point detection and are limited to short-term analysis, while deep learning models, despite their accuracy, often operate as black boxes with limited physiological interpretability. To address these challenges, we propose a physiology-guided hybrid framework for personalized BP estimation that couples a convolutional neural network (CNN) branch capturing global and local waveform dynamics with a morphology-prior branch that explicitly encodes person-specific vascular characteristics. By embedding a morphology-based feature set that explicitly encodes individual vascular characteristics, the proposed framework enhances personalization and reduces dependence on large-scale training datasets. Evaluated on a subset of the MIMIC-III database under a subject-specific (personalized) testing protocol, the proposed personalized physiology-guided hybrid approach achieved mean absolute errors (MAEs) of 3.77 mmHg for systolic BP and 2.36 mmHg for diastolic BP, corresponding to relative improvements of 43.7% and 32.4% over a subject-specific (personalized) CNN-only baseline. SHAP-based analysis confirmed that the introduced morphology-prior features align with individual vascular characteristics, reinforcing per-subject interpretability. These findings highlight the potential of personalized, physiology-guided hybrid learning with novel morphological descriptors for accurate and explainable BP monitoring in real-world settings.

0.57

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.61
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.61
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

Interaction-Gated Time-Frequency Learning for Parameter-Efficient PPG-Based Heart Rate Estimation

cs.LG cs.AIeess.SP ·2026-10-20 ·Anh Khoi Pham, Phat Lam, Thien Truong Nguyen Ly, Lam Pham
benchmark similarity 0.60
Abstract · Conference preprint, accepted at SoICT 2026

Photoplethysmography (PPG) enables low-cost and non-invasive heart rate (HR) monitoring but remains sensitive to waveform distortion, physiological variability, and measurement interference. Temporal waveform characteristics and frequency-domain periodicity provide complementary information for HR estimation; however, effectively exploring and integrating these representations within a compact model remains challenging. This paper proposes TF-IG, a parameter-efficient interaction-gated time-frequency learning framework for PPG-based HR estimation. TF-IG employs a dual-branch architecture in which a temporal branch captures pulse morphology via dilated depthwise-separable convolutions, while a frequency branch extracts cardiac periodicity information from bounded log-spectrogram representations. To combine the two domains, we introduce an interaction-gated fusion module that explicitly models feature agreement and discrepancy, while also learning feature-wise weights to balance temporal and spectral information. A parameter-shared regression head further maps the temporal, spectral, and fused representations into the final HR prediction space. Experiments on the benchmark BIDMC PPG and Respiration Dataset using a subject-exclusive training, validation, and test protocol show that TF-IG achieves a mean absolute error (MAE) of 1.227 BPM, a root mean square error (RMSE) of 2.060 BPM, a Pearson correlation coefficient of 0.9934, and 92.28 percent of estimates within 3 BPM, while remaining parameter-efficient with only 84.6K parameters. Ablation results further demonstrate the complementary contributions of the temporal and frequency branches, interaction-gated fusion, and shared regression head. These results indicate that explicitly modeling cross-domain interactions provides an effective accuracy-complexity trade-off for lightweight PPG-based HR estimation.

0.11

CALM-BP: Observation-Matched Physiological Semantic Grounding for Non-Contact Blood Pressure Estimation

cs.HC ·2026-08-22 ·Haiyang Sun, Boyuan Gu, Yongjie Liu
similarity 0.60
Abstract · 17 pages, 3 figures, 12 tables

Language grounding increasingly involves non-text observations whose structure is not naturally expressed as words or objects. We study this problem for physiological time series in non-contact blood pressure (BP) estimation: remote photoplethysmography (rPPG) provides measured evidence about bodily state, but numerical pipelines expose little semantic structure about why a window is reliable or how its cues should be fused. We introduce observation-matched physiological semantic grounding, where language-derived priors must be constructed from the same rPPG observation, remain bounded by an auditable prior contract, and avoid BP-label or identity leakage. CALM-BP does not treat language as new physiological evidence; instead, it verbalizes rPPG descriptors into a controlled semantic interface while rPPG remains the primary haemodynamic evidence source. FlowBP-Set pairs forehead observations, synchronized BP labels, and structured physiological prompts from 81 participants. Main BP results, direct cross-dataset evaluation, language-realization ablation, and observation-mismatch controls test whether language helps because it organizes the current physiological observation rather than because it is arbitrary auxiliary text. The FlowBP-Set dataset contains sensitive facial video and physiological recordings and is therefore not publicly available due to privacy and ethical restrictions. Data access may be considered upon reasonable request and subject to applicable ethical and institutional approval.

0.16

HiPPT: Physiology-Grounded Wearable PPG Representation Learning via Multi-Scope Text Alignment

cs.AI ·2026-10-10 ·Jiaqi Wang, Wei Chen, Xiaoyu Li, Lexian Xia, ShuaiLong Tang +5 more
similarity 0.60
Abstract

Reusable wearable PPG representations should capture local pulse morphology and broader physiological regularities. Existing pretraining objectives, however, usually apply supervision at the recording or pair level, overlooking that different concepts become reliable over different scopes of waveform evidence. We propose HiPPT, a physiology-grounded framework that matches each supervision source to its appropriate evidence scope. We construct a PPG-Text corpus of over 4 million wrist-worn recordings from 202K users, pairing recordings with waveform-derived morphology and metadata-derived context descriptions. HiPPT combines record-level morphology alignment, which grounds individual recordings in pulse characteristics, with cross-recording context alignment, which aggregates recordings sharing the same metadata tuple to capture context-consistent regularities. Waveform-guided text modeling further recovers masked contextual concepts from PPG patch representations, providing fine-grained waveform-text supervision. Across six downstream tasks spanning blood pressure, vascular stiffness, physiological attributes, and cross-dataset heart-rate estimation, HiPPT achieves the best result on the primary linear-probing metrics. The aligned space also supports zero-shot profiling of age group, sex, and BMI category, individually and jointly, with performance improving as more recordings are aggregated. These results show that evidence-scope matching yields transferable and semantically accessible wearable PPG representations. Code and pretrained weights will be released.

0.23