CS Paper Radar

Packet-Level Complex CIR Tracking for Communication-Native mmWave Sensing: An 802.11ad Testbed

Raquel Marina Noguera Oishi, Haoqiu Xiong, Hany Assasa, Sofie Pollin

eess.SP ·submitted 2026-09-14 14:13 UTC · v1

Abstract

Commercial millimetre-wave (mmWave) Wi-Fi platforms based on IEEE 802.11ad/ay have demonstrated sensing capabilities, but they provide limited visibility into the packet-level measurements and synchronisation mechanisms that determine temporal coherence. We present a programmable 60~GHz IEEE 802.11ad testbed that exposes the complete complex 128-tap channel impulse response (CIR) for every detected packet. This access exposes packet-to-packet delay shifts and common phase drift that commercial-transceiver studies generally do not characterise. We develop a delay-profile alignment method and define a static-reference relative CIR phase that cancels common drift while preserving target-induced variation. We use 30~s respiration sensing to evaluate long-term phase stability for sub-wavelength motion tracking. Across 39 recordings, median absolute waveform correlation increases from 0.41 (timestamp regularised) to 0.52 (delay aligned) and 0.61 (relative-phase calibrated); breathing-rate mean absolute error decreases from 5.1 to 4.1 and 3.6~breaths/min. The results demonstrate controlled characterisation and stabilisation of communication-native WiGig CIR measurements on a fully programmable physical layer.

Closest papers

Nearest neighbours by meaning across the whole index.

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.60
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.57
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.55
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

Bistatic Delay-Doppler Sensing for 3D Target Localization in Distributed Wi-Fi Systems

eess.SP cs.IT ·2026-10-11 ·Kyungmin Hong, Moein Ahmadi, Thomas Stifter, Mounim A. El Yacoubi, Bhavani Shankar Mysore R
published similarity 0.54
Abstract · 6 pages, 6 figures, 2 tables. Accepted for presentation at the 1st IEEE Conference on Integrated Sensing and Communications (ISAC), Lisbon, …

This paper investigates how bistatic delay information improves the observability and localization performance of 3D moving targets in distributed Wi-Fi sensing. Motivated by emerging IEEE 802.11bf WLAN sensing, we consider one transmitter, multiple distributed receivers, and a single target with unknown position and velocity. We compare Doppler-only sensing with delay-Doppler sensing, in which delay-capable receivers provide additional bistatic path-length information for target localization. We derive the Fisher information matrix (FIM) and the position equivalent FIM (EFIM) for both sensing formulations. The resulting observability analysis shows that Doppler-only localization generically requires six receivers, whereas delay-Doppler localization can become locally identifiable with three receivers under non-degenerate geometry. We further study mixed receiver architectures in which only a subset of receivers provides delay estimates. Simulations with Wi-Fi-like bandwidths confirm the transition and quantify the roles of bandwidth, Doppler noise, receiver geometry, and delay-capable receiver availability.

0.32

Continuous-Phase Frequency-Hopping MIMO Signaling and Processing for ISAC

eess.SP ·2026-10-16 ·Yi Wang, Xianxiang Yu, Jing Yang, Tao Fan, Linlong Wu +2 more
similarity 0.54
Abstract · 22 pages, 13 figures, including appendices

Frequency-hopping MIMO integrated sensing and communications (FH-MIMO-ISAC) supports agile multidimensional signaling but faces challenges in phase-continuous transmission, demodulation without channel-phase information, and coherent processing of multi-frequency echoes. We propose a continuous-phase frequency-hopping (CP-FH) MIMO ISAC waveform with matched communication and radar processing. Information is conveyed jointly by frequency combinations and continuous-phase-modulation symbols. CPM phase accumulation and frequency-hopping linear-frequency-modulation phase compensation maintain phase continuity and reduce spectral leakage. We derive exact inter-element orthogonality conditions, residual cross-correlation bounds, and a bound on averaged transmit-beampattern ripple. For communication, projection-energy demodulation requires no channel-phase information and approximates least-squares detection under weak inter-branch correlation. It separates frequency-combination search from CPM-symbol decisions, reducing complexity while retaining direct joint-search decisions. For radar, structure-matched coherent processing combines space-time-frequency matched filtering, velocity-consistent Doppler focusing, and frequency-aperture focusing to form a three-dimensional coarse-range--velocity--fine-range response. It reduces Doppler-mismatch loss and extra detections from periodic range grating lobes in conventional pulse-Doppler processing. We further derive the joint range response, output signal and noise powers, and receive beampattern. The analysis characterizes target-discrimination limits under periodic ambiguity and shows that the proposed processor preserves frequency-aperture range resolution and full-aperture angular resolution, with equal output noise power under the stated conditions.

0.31

Cross-Room Passive WiFi Tracking: Joint Estimation of Target Trajectory and Virtual Transmitter Location

eess.SP ·2026-09-28 ·Heping Wang, Zhongqin Wang, Henk Wymeersch, J. Andrew Zhang
similarity 0.53
Abstract

Indoor bistatic WiFi sensing must often operate across rooms, where intervening walls block the direct line-of-sight (LOS) path between the transmitter (Tx) and receiver (Rx). Recovering a human trajectory from channel-state-information (CSI)-derived delay, angle-of-arrival (AoA), and Doppler estimates is difficult because the Tx position is often unknown and NLOS propagation is inconsistent with direct-path geometry. This paper presents CoTrack, a self-calibrating passive WiFi tracking scheme that does not require the Tx position. CoTrack extracts one dominant human-induced response and represents its transmitter-side propagation by a virtual Tx, which it estimates jointly with the human trajectory. Because similar measurements can be explained by different virtual-Tx--trajectory pairs, CoTrack uses multi-start nonlinear least squares and accepts an initialization only when the best-fitting candidates concentrate around a common virtual-Tx position. It then applies online alternating optimization for continuous tracking. We analyze the local identifiability of the joint estimation problem and derive the corresponding Cramér--Rao bound. Across six LOS and cross-room NLOS experiments, CoTrack achieves a median trajectory error of 1.14m(80th percentile: 1.42m) and a median virtual-Tx discrepancy of 0.47m(80th percentile: 0.54m).

0.50

AFDM-Enabled ISAC in Dynamic Environments: Fundamentals, Technologies and Opportunities

eess.SP ·2026-09-04 ·Linchu Chen, Zhendong Li, Zhou Su, Lin Chen, Wen Chen
similarity 0.53
Abstract

Dynamic environments pose fundamental challenges to integrated sensing and communication (ISAC), particularly due to severe Doppler effects, rapidly time-varying channels, and the intricate coupling between delay and Doppler shifts. Affine frequency-division multiplexing (AFDM), with its inherent capability of characterizing and separating delay and Doppler effects, has emerged as a promising waveform for dynamic ISAC. This article provides a comprehensive overview on AFDM-enabled ISAC in dynamic environments, covering its fundamental principles, distinctive advantages, representative application scenarios, and key enabling technologies. We first characterize the key features of ISAC in dynamic environments and introduce the fundamentals of AFDM, followed by an analysis of scenarios where AFDM can provide significant performance benefits. Then, several key enabling technologies for AFDM-based ISAC in dynamic environments are elaborated upon, accompanied by case studies on the critical aspects therein. Finally, open challenges and promising future research directions are discussed, aiming to provide a comprehensive reference for researchers and practitioners while inspiring further innovation in this emerging field.

0.21

Channel Modeling for Phase-Based Ranging

eess.SP ·2026-08-18 ·Till Droemmer, Markus Gardill
similarity 0.53
Abstract · 4 pages, 4 figures. Submitted to IEEE Radio and Wireless Week (RWW) 2027

This paper presents a Python-based simulation framework for the physical layer of Bluetooth Channel Sounding in accordance with Bluetooth Core Specification v6.2. The simulator implements Mode 3 phase-based ranging across 72 active tones in the 2.4 GHz ISM band and supports multiple propagation conditions, including free-space, static multipath, and IEEE 802.15.4a stochastic multipath channels. In addition, it models relevant hardware and interference effects such as phase noise, phase ramp, carrier frequency offset, IQ imbalance, ADC quantization, and narrowband interference from co-located Wi-Fi systems, with parameters derived from commercial SoC datasheets and field measurements. The framework enables controlled and repeatable analysis of physical layer effects that are difficult to isolate in over-the-air experiments and are not sufficiently represented in existing higher-level simulation tools. This work focuses exclusively on physical layer signal generation, channel modeling, and impairment injection, providing a foundation for future studies on Bluetooth Channel Sounding ranging and localization algorithms.

0.28