CS Paper Radar

A Subcarrier-Aware Approach for Robust Respiratory Monitoring with Commodity Wi-Fi

Pei Tang, Yunpeng Ge, Ivan Wang-Hei Ho

eess.SP ·submitted 2026-08-26 10:28 UTC · v1

Abstract

Wi-Fi sensing has emerged as a promising modality for contact-free respiratory monitoring in home healthcare due to its ubiquity. However, conventional approaches typically treat Channel State Information (CSI) subcarriers uniformly, neglecting their heterogeneous responses to breathing motions. To address this limitation, we propose a subcarrier-aware sensing framework that characterizes subcarrier-dependent respiratory sensitivities and exploits them for informative subcarrier selection. Based on the statistical properties of breathing-sensitive subcarriers, we further develop an unsupervised clustering-based breathing estimation method for robust respiratory monitoring. Experimental results show that the proposed method achieves 97% breathing rate estimation accuracy and reduces the mean absolute error (MAE) by 0.45 breaths per minute (bpm) compared with baseline methods. Furthermore, we extend the analysis to breathing-pause detection, which derives an amplitude-attenuation-based threshold mechanism. Under breathing pauses, the proposed method achieves an MAE of 1.6 bpm in breathing rate estimation. These results demonstrate the robustness and effectiveness of the proposed framework across different scenarios and its potential for contactless home healthcare monitoring.

Comment
13 pages, 24 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Acoustic Respiratory Phase Detection on Mobile Devices

cs.AI cs.LG ·2026-11-12 ·Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina Quero
similarity 0.58
Abstract

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

0.14

Spectral Features Dominate BCG Respiratory-Event Detection: A Large-Scale Patient-Independent Comparison of Feature Groups in Sleep Apnea Patients

cs.LG ·2026-08-28 ·Israel Campero Jurado, Zoe Bousraou, Lara Benning, Sara Padilla Neira, Alexander Breuss +3 more
similarity 0.57
Abstract · 36 pages, 7 figures

Unobtrusive ballistocardiographic (BCG) sensing is a promising modality for long-term sleep-apnea monitoring, yet it remains unclear which signal features are most discriminative for respiratory-event detection. We present a literature-guided, patient-independent comparison of ten BCG feature groups using a 512-sensor capacitive pressure mat recorded simultaneously with respiratory polygraphy in 155 patients (52 female, 103 male) undergoing in-hospital evaluation for obstructive sleep apnea. Features were extracted from six spatially distinct signal channels, yielding a 191-dimensional feature vector spanning general statistical, time-domain, frequency-domain, wavelet, frame-energy, and nonlinear complexity descriptors. Under strict leave-one-patient-out cross-validation for binary classification of respiratory-event windows versus event-free reference windows, Random Forest and Histogram Gradient Boosting achieved AUC-ROC of 0.967 and 0.969 and AUC-PR of 0.977 and 0.979, respectively. Feature-importance analysis revealed that frequency-domain features dominate discrimination: breathing-band power in the 0.1-0.4 Hz range accounted for 30.3% of total discriminative information across all spatial channels, and Fast Fourier Transform spectral-shape descriptors of the adaptively preprocessed channel contributed a further 15.1%. AUC and curve-length features provided the main complementary time-domain evidence (21.5%), whereas wavelet-derived and nonlinear features contributed smaller secondary effects (10.4% combined across 59 features). Frequency-domain and time-domain features together accounted for 67% of total discriminative information, demonstrating that a compact, interpretable subset of the full feature library achieves clinically relevant performance under patient-independent validation and providing an empirical basis for feature selection in future BCG systems.

0.26

VitalFR3: Wireless Vital Sign Sensing in the Upper Mid-Band (FR3)

eess.SP ·2026-10-03 ·Gholamreza Bakhshi, Hatem Abou-Zeid
similarity 0.56
Abstract · 14 pages, 12 figures

Frequency range 3 (FR3) is being explored for sixth-generation (6G) integrated sensing and communication (ISAC).However, experimental evidence on the feasibility of physiological sensing in this band is limited. This paper presents VitalFR3, an SDR-based frequency-modulated continuous-wave (FMCW) measurement platform that integrates a direct-sampling Ettus USRP X440 with a SignalCraft SC2470 frequency converter. To the best of our knowledge, this is the first calibrated SDRbased FMCW platform evaluated for respiration and cardiac-rate estimation from human measurements across multiple FR3center frequencies. Using a 100 MHz waveform, we operate the platform at six RF center frequencies from 10 to 22.5 GHz.We demonstrate how to characterize and calibrate the completeVitalFR3 transmit and receive path directly from loopback recordings, achieving a magnitude error below 0.061 dB at all six frequencies. We then propose a low-complexity end-to-end processing pipeline for vital sign estimation. This involves the identification of a persistent target-associated response in fast time, respiratory tracking in slow time, followed by cardiac- rate estimation. The system is evaluated across 16 human measurements, achieving a respiratory-rate mean absolute error of 0.758 breaths per minute, and the majority of the cardiac- rate estimates fall within 5 BPM of their reference rates. In a separate breath-hold measurement, the estimated cardiac rate is 84.3 BPM versus approximately 84.5 BPM from the reference. These results establish VitalFR3 as a calibrated and configurable measurement platform for experimental physiological sensing across FR3.

0.18

Through-Wall Detection using Software-Defined Radio based on adaptive Principal Component Analysis

eess.SP ·2026-09-11 ·Dinuli Naotunna, Wenchao Li, Sanka Piyaratna, Phil Wandel
similarity 0.55
Abstract · 15 pages, 7 figures

Through-Wall Detection (TWD) using opportunistic WiFi signals enables non-invasive sensing for security and rescue applications; however many existing approaches rely on controlled access points or specialised hardware. This paper presents a TWD system that extracts Channel State Information (CSI) from ambient WiFi packets using a customised software-defined radio (SDR), Bluebottle, without requiring transmitter control. The key contribution is a spectral-domain scoring mechanism for adaptively selecting motion-relevant principal components from a Principal Component Analysis (PCA) decomposition of the CSI, using Welch power spectral density estimates to quantify each component's signal-to-noise ratio and spectral concentration within the frequency band associated with human motion. The selected components are then analysed using a continuous wavelet transform to robustly identify time-localised motion events. Experimental results demonstrate that the proposed adaptive component-selection method consistently reduces false detections and produces sharper time-frequency energy ridges compared to conventional fixed-component PCA.

0.26

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.53
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

eess.SP cs.LGcs.NI ·2026-08-31 ·Navaneeth Krishnan Kamalakannan, Janakiraman Kamalakannan, Harinisri Velmurugan
code/data similarity 0.53
Abstract · 6 pages, 4 figures, 3 tables. Submitted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code and experimental arti…

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless losses, energy constraints, and edge-computation latency. We introduce Physiological Information Reliability (PIR), a cross-layer framework that represents physiological information value jointly with wireless, energy, and computation states and uses a contextual bandit to adapt sensing and communication decisions. We integrate multimodal ECG/PPG signal-quality estimation with physiological information value and an adaptive network-coding layer under burst-erasure conditions. Across controlled multiseed experiments, PIR-LinUCB demonstrates a promising low-energy operating point while maintaining medical latency constraints and competitive physiological estimation performance relative to fixed and heuristic policies. We analyze the resulting accuracy-energy-latency trade-offs and identify limitations of proxy PIV estimation and simulated communication dynamics. These results provide an initial computational demonstration of physiological-information-aware resource allocation and motivate future clinical and real-channel validation.

0.30

CORAL: A Modality Invariant Framework for Robust Vital Sign Rate Estimation Using Correloform Analysis

eess.SP q-bio.QM ·2026-08-15 ·Jacob Trueb, Amey Kasbe, Aniruddh Srinivasan
benchmark similarity 0.52
Abstract · main manuscript: 11 pages, 2 tables, 4 figures supplemental materials: 25 pages, 4 tabes, 31 figures

Heart rate and respiration rate are crucial vital signs. We present CORAL to address challenges in automating continuous vital sign monitoring 1) in-hospital across broader populations (age, disease states), 2) at-home in telehealth and wellbeing applications (noise, placement), and 3) across data modalities (ECG, PPG, SCG, BioZ, etc.). We re-introduce Short-Time Autocorrelation Functions (STACFs) to introduce the correloform - a highly interpretable 2D signal transformation for tracking periodicity over time - and define CORAL as a generic analytical framework for robust rate estimation of quasi-periodic signals. We rigorously benchmark CORAL to show ubiquitous application in biosignals via capabilities arising by mathematical construction rather than domain-specific engineering, including rate estimation, resilient noise handling, automatic channel selection, and signal quality indication. CORAL achieves excellent instantaneous noninvasive fetal HR agreement in FECGSYNDB (F1 = 0.999) and ADFECGDB (F1 = 1.000). With difficult NICU neonates, CORAL estimates RR from wearable BioZ at r = 0.858 against breath-interval RR from simultaneous wired Philips impedance. CORAL SCG HR on CEBS achieves r = 0.990 and in free-living activity r = 0.970 when compared against commercial ECG. Without QRS detection, CORAL's instantaneous HR agrees with Pan-Tompkins and NeuroKit2 detectors as closely as they agree with each other (MIMIC-IV ICU ECG r = 0.87 to each vs. 0.88 between them). CORAL's HR standard deviation correlates strongly with interval-based HRV SDNN, even from mechanical SCG (CEBS r = 0.733) and across an ICU ECG cohort (r = 0.768).

0.10

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.52
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26