Pre- and Post-Exercise Monitoring of Physiological Skin States in Sportsmen Using 77 GHz FMCW Radar and Wavelet Scattering Transform

Vijith Varma Kotte, Muhammad Mahboob Ur Rahman, Sajid Ahmed, Tareq Y. Al-Naffouri

eess.SP ·submitted 2026-09-19 18:00 UTC · v1

Abstract

This paper presents a contactless radar sensing framework that classifies physiologically-induced changes in the superficial skin layer following intense fixed-duration physical activity along with water intake restriction. A 77 GHz frequency-modulated continuous wave (FMCW) radar is used to capture high-resolution range profiles from the subject's chest, seated in front of the radar, before and after sports activity. Since the electromagnetic penetration into biological tissue is inherently shallow at millimeter-wave frequencies, the sensing is confined primarily to the stratum corneum and upper epidermis. We demonstrate that exercise-induced thermoregulation, perspiration residue deposition, and transient shifts in superficial tissue hydration produce measurable alterations in quasi-static radar reflectivity. We utilize single-chirp snapshots of duration 102.4 micro sec in order to suppress confounders such as slow-varying cardiopulmonary motion, followed by lightweight feature extraction via the Wavelet Scattering Transform (WST) and classification using light-weight machine learning models suitable for edge nodes. Leave-one-subject-out cross-validation on a dataset of 15 sportsmen measured pre- and post-exercise yields a mean classification accuracy of 91.55% with a 95% confidence interval of [84.27, 98.83]%. Interpretability analysis reveals that low-order scattering coefficients (capturing overall signal energy and amplitude stability) dominate discriminative power, consistent with quasi-static changes in skin surface permittivity. The results establish a proof-of-concept for radar-based, edge deployable classification of post-exercise skin states, opening new avenues for non-contact physiological monitoring in sports science.

Comment
4 pages, 3 figures, 1 table, under review with a journal

Closest papers

Nearest neighbours by meaning across the whole index.

A Universal Raw-IQ Radar Encoder for Cross-Sensor Human Sensing

cs.CV cs.LG ·2026-11-03 ·Jonas Leo Mueller, Dario Zanca, Sebastian Hoefler, Jan Petermann, Thomas Altstidl +3 more
publishedbenchmarkpositioncode/data similarity 0.54
Abstract · Accepted at the 2027 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV)

Radar-based human sensing typically relies on end-to-end task-specific models trained on hand-chosen signal projections, which generalize poorly across unseen users, tasks, and hardware. We argue that the dominant signal processing choice, the micro-Doppler spectrogram, is a poor starting point for transfer because it keeps the Doppler axis, which carrier frequency rescales, and discards the angular axis, which carrier frequency leaves unchanged. We instead pretrain a convolutional beta-VAE without labels on clutter-removed raw radar measurements from four platforms spanning 60 and 77 GHz and 4 to 12 virtual antennas, aligned by a unified spectral interpolation grid. For every downstream benchmark the encoder stays frozen, and only a small supervised temporal classifier is trained on its embeddings. We compare against supervised models trained end to end on each benchmark and a pretrained radar foundation model across ten settings covering activity, gesture, sign-language, and gait recognition. When the test users and the radar are seen during training, our encoder is best on all five benchmarks. For users never seen in training, it leads on three of four benchmarks, by 4.8 to 23.2 points. On subject-disjoint gait recognition, it is best for each of the four held-out subjects and 8.3 points above the strongest baseline on average, even though its pretraining excluded every recording of this radar. Excluding the test radar from pretraining costs at most 5.3 points on any benchmark. Code is available at https://github.com/jonasmueler/UniversalRadarEncoder_WACV.

0.50

Learning to Assess Heartbeat Observability for mmWave Heart-Rate Sensing

cs.AI ·2026-10-02 ·Yuxuan Hu, Shilin Shan, Jianfei Yang, Feng Xu
code/data similarity 0.54
Abstract · 19 pages, 11 figures. Project page: https://yuxuanhu9.github.io/HEAR/

Contactless heart-rate sensing with millimeter-wave (mmWave) radar requires assessing whether individual measurements support reliable estimation. We study learning to assess heartbeat observability, defined as the readability of the heartbeat component in an acquired phase spectrum, for selective heart-rate estimation. Coherent superposition of scatterer returns can suppress this component even under similar macroscopic observation geometry, motivating assessment directly from acquired measurements. To obtain training supervision across different observability conditions, we develop a controllable multi-scatterer frequency-modulated continuous-wave (FMCW) simulator. Agreement between the dominant heartbeat-band peak and the known heart rate provides an automatic observability label for each simulated measurement. We propose HEAR (Heartbeat Estimation with Assessed Reliability), a compact dual-task Transformer that jointly predicts an observability score and heart rate. Its input combines spectral magnitudes with frequencies relative to the respiration fundamental, providing context for respiratory harmonics. Trained solely on simulated observations, HEAR transfers zero-shot to two public real-world datasets collected at 60 and 120 GHz from 134 subjects. The same learned score supports selective prediction with both HEAR's own heart-rate head and multiple existing estimators. On the 120 GHz dataset, score-based selection reduces the HR head's mean absolute error from 17.9 BPM at full coverage to 1.6 BPM at 50% coverage. The complete pipeline achieves an end-to-end processing latency of 50.8 ms on an edge device. Project page: https://yuxuanhu9.github.io/HEAR/.

0.38

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

cs.LG ·2026-08-20 ·Anton Lambrecht, Reda El Hail, Xianjun Jiao, Pieter Crombez, Dominique Schreurs +3 more
similarity 0.52
Abstract · This paper has been submitted to IEEE Access Journal and is currently undergoing review

Despite their growing importance for contact-free radio frequency (RF) based healthcare monitoring, different radio technologies such as frequency-modulated continuous wave (FMCW) radar, impulse radio ultra-wideband (IR-UWB), and Wi-Fi sensing are rarely compared under identical deployment conditions, as existing studies typically differ in hardware, datasets, and evaluation methodologies. In addition, the performance of ceiling-mounted radars, despite their practical deployment and cost advantages in healthcare environments, remain underexplored. Therefore, this paper presents a controlled comparison and analysis of ceiling-mounted FMCW, IR-UWB, and Wi-Fi sensing using synchronized recordings from 20 participants across six room layouts. All technologies are evaluated with the same convolutional neural network (CNN) on both a fine-grained 10-class human activity recognition (HAR) task and a coarse 4-class sleep monitoring task. IR-UWB achieves the highest cross-subject activity recognition performance (89.0% macro F1), while FMCW generalizes best to unseen room layouts (83.8% macro F1). For sleep monitoring, all technologies exceed 92% macro F1 in unseen environments. The results reveal a fundamental trade-off between recognition performance and environmental robustness, which can be explained through differences in range resolution, antenna diversity, Doppler resolution, and spatial information retention. These findings provide practical guidelines for the design of healthcare-oriented RF sensing systems.

0.24

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.50
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

On-device Detection of Wearer-induced NLOS on Chest-worn UWB Tags: Machine Learning, Link Indicators, or Both?

cs.LG ·2026-10-30 ·Markus Gallacher, Vu Anh Minh Le, Matteo Trobinger, Davide Vecchia, Carlo Alberto Boano +1 more
similarity 0.50
Abstract · Submitted to ACM Transactions on Sensor Networks

Ultra-wideband (UWB) enables high-accuracy distance estimation (ranging), but performance degrades in non-line-of-sight (NLOS) conditions. When UWB tags are worn, the human body inevitably causes a wearer-induced NLOS (WNLOS), yielding significant errors; still, despite its relevance, WNLOS remains understudied. Moreover, WNLOS detection typically must occur on-device at the tag, requiring classification accuracy to be balanced against tight runtime and energy constraints often hard to meet with machine learning (ML) -- the dominating NLOS classification approach. Meanwhile, UWB radio link indicators (LI) offer a faster and lightweight alternative that has rarely been explored. We study existing on-device ML and LI classifiers when applied to WNLOS, and propose novel hybrid ones exploiting their complementarity. We focus on chest-worn tags and analyze 21 classifiers on a dataset of 1.5 million samples across channels, PHY settings, environments, subjects, and orientations. Results show that while all of them achieve good classification accuracy, relative performance, including ranging errors due to misclassification, depends heavily on channel and PHY configuration. Runtime and energy efficiency also vary dramatically; some techniques offer marginal accuracy gains while consuming up to 39.6x more energy. Therefore, we also introduce a recommender tool to identify optimal classifiers under user-defined constraints, publicly released with our dataset.

0.26

RT-VSS: In-House Ray Tracing for Vital Signs Sensing in FR3 Band

eess.SP ·2026-09-14 ·Rudranil Chattopadhyay, Zhuangzhuang Cui, Achiel Colpaert, Sofie Pollin
similarity 0.50
Abstract · Submitted to the IEEE conference for potential publication

Vital Signs Sensing, enabled by the evolution of wireless communications, is inherently challenging as the chest's micro-Doppler signatures can be corrupted by multipath, body movement and noise. Additionally, the prospects of the Frequency Range (FR) 3 band, spanning 7-24 GHz, are compelling due to centimeter-scale wavelength improving phase sensitivity to chest motion, while its abundant bandwidth and rich multipath enhance temporal and spatial diversity. In this paper, we validate the feasibility of using cellular communications in the FR3 band to monitor a human's breathing and heartbeat in an indoor environment. Using Blender to model physiologically accurate vital-signs signals as ground truth and Sionna Ray Tracing simulations, we find that it is feasible to extract breathing and heartbeat waveforms at FR3 frequencies. Furthermore, we perform a comparative analysis of ISAC performance against representative sub-6 GHz (FR1) and mmWave (FR2) frequencies, indicating the utility of the study across the frequency bands.

0.26

A passive, battery-free flexible metasurface for implantable millimetre-wave radar glucose sensing

eess.SP physics.bio-ph ·2026-11-13 ·Kavya Saravanan, Rohini Ramachandran, Jean Pierre Ndabakuranye, Isabelle Shearer, Gursimran Singh +6 more
unusual similarity 0.50
Abstract

Continuous glucose monitors (CGM) break the skin barrier and require periodic sensor replacement. We investigated whether a passive, battery-free flexible metasurface, implanted beneath tissue and read by a commercial 60 GHz radar, can track blood glucose levels. The metasurface contained no electronics or reagents. We fitted a conical helix to the in-phase and quadrature radar signals across the frequency sweep and used its mean radius (the spiral radius) as the glucose-dependent feature. We tested glucose concentrations of 25 to 400 mg/dL in saline solution with and without the metasurface, and 196 to 596 mg/dL of total glucose in porcine whole blood beneath ex vivo porcine tissue and in a murine cadaver model with pulsatile blood flow. The metasurface was essential for achieving a monotonic sensor response; in saline, the coefficient of determination ($R^2$) of a logarithmic fit increased from 0.18 without the metasurface to 0.90 with it. In a murine (rat) cadaver model, the signal's spiral radius increased monotonically with glucose concentration despite pulsatile flow ($R^2$ = 0.91), and this monotonic behavior persisted through up to 6 mm of tissue. Although sensitivity decreased at higher glucose levels, each discrete concentration step remained clearly detectable. These results demonstrate that a shallow, passive implant paired with a commercial radar can effectively track blood glucose without requiring onboard electronics or batteries.

0.25

Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing

cs.LG cs.ET ·2026-09-26 ·Constantino Álvarez Casado, Nhi Nguyen, Mohammad Rakibur Rahman, Le Nguyen, Manuel Lage Cañellas +2 more
similarity 0.49
Abstract · 9 pages, 4 figures, 7 tables, 24 numbered equations. Extended version of a conference submission, with additional methodological details, im…

Millimeter-wave (mmWave) radar and RGB-D cameras can record cardiac and respiratory waveforms continuously and without contact, but labeled recordings remain scarce because every label requires a supervised acquisition session. Self-supervised pretraining can exploit the unlabeled signals, yet contrastive methods depend on signal transformations and negative pairs whose validity is uncertain for cardiorespiratory data, where time warping changes breathing rate and distant windows can share the same physiological state. We present Phenomenon-Graph JEPA, a joint-embedding predictive architecture that learns from four processed one-dimensional streams without negative pairs or synthetic augmentation in its base configuration. Each stream is encoded by a temporal convolutional branch and a band-limited spectral branch. During pretraining, the model predicts stopped target embeddings along typed edges, which connect streams assigned to the same physiological phenomenon, and forward in time within a state episode. We treat this physiological typing as a testable hypothesis and compare it with wrong-edge and all-pairs prediction graphs. In the OMuSense-23 dataset, pretraining improves label-efficiency area over matched supervised training by 3.91 percentage points (95% interval 2.08 to 5.80, Holm-adjusted p = 0.006), and by 3.74 points under a second configuration evaluated on the same test participants. However, the wrong-edge and all-pairs controls do not establish a benefit from physiological typing. Optional Takens-inspired delay coordinates improve a validation comparison with learned history, whereas two wrist-only WESAD protocols do not establish a pretraining advantage. The study therefore separates the measured benefit of predictive representations from the physiological prior used to organize their training.

0.20