CS Paper Radar

On-device Detection of Wearer-induced NLOS on Chest-worn UWB Tags: Machine Learning, Link Indicators, or Both?

Markus Gallacher, Vu Anh Minh Le, Matteo Trobinger, Davide Vecchia, Carlo Alberto Boano, Gian Pietro Picco

cs.LG ·submitted 2026-10-30 14:28 UTC · v1

Abstract

Ultra-wideband (UWB) enables high-accuracy distance estimation (ranging), but performance degrades in non-line-of-sight (NLOS) conditions. When UWB tags are worn, the human body inevitably causes a wearer-induced NLOS (WNLOS), yielding significant errors; still, despite its relevance, WNLOS remains understudied. Moreover, WNLOS detection typically must occur on-device at the tag, requiring classification accuracy to be balanced against tight runtime and energy constraints often hard to meet with machine learning (ML) -- the dominating NLOS classification approach. Meanwhile, UWB radio link indicators (LI) offer a faster and lightweight alternative that has rarely been explored. We study existing on-device ML and LI classifiers when applied to WNLOS, and propose novel hybrid ones exploiting their complementarity. We focus on chest-worn tags and analyze 21 classifiers on a dataset of 1.5 million samples across channels, PHY settings, environments, subjects, and orientations. Results show that while all of them achieve good classification accuracy, relative performance, including ranging errors due to misclassification, depends heavily on channel and PHY configuration. Runtime and energy efficiency also vary dramatically; some techniques offer marginal accuracy gains while consuming up to 39.6x more energy. Therefore, we also introduce a recommender tool to identify optimal classifiers under user-defined constraints, publicly released with our dataset.

Comment
Submitted to ACM Transactions on Sensor Networks

Closest papers

Nearest neighbours by meaning across the whole index.

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

cs.LG ·2026-11-06 ·Jingjing Zou, Yixin Wang
code/data similarity 0.61
Abstract · 26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

0.29

Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project

cs.ET cs.AIcs.ARcs.CR+2 ·2026-11-15 ·Luciano Bozzi, Christian Celidonio, Umberto Nuzzi, Massimo Biagini, Stefano Cherubin +17 more
publishedbenchmark similarity 0.60
Abstract · Pre-print version

The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: $\mathrm{Accuracy}=0.901\!\pm\!0.023$, $\mathrm{F1}=0.920\!\pm\!0.019$), while a feature-based Transformer attains the highest AUC ($0.963\!\pm\!0.025$), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.

0.34

A Rapid Pipeline for Training and Deploying ML Models on WeBe Band

cs.AI cs.LGcs.PF ·2026-09-24 ·Ehsan Kourkchi, Asmita Asmita, Houman Homayoun, Mahdi Eslamimehr
publishedcode/data similarity 0.60
Abstract

Developing optimized machine-learning algorithms for edge devices with limited computational and memory resources is challenging, time-consuming, and highly dependent on device-specific constraints. In this work, we streamline an edge ML workflow to enable rapid development, optimization, and deployment of machine-learning (ML) models directly on the WeBe Band, a wrist-worn wearable device designed for multimodal physiological data monitoring. The proposed system automatically generates hardware-efficient ML models that can be easily integrated into the WeBe core firmware, supporting AutoML, hardware-aware quantization, and performance profiling to build models that meet desired latency targets while remaining compatible with device memory and power limitations. The proposed framework tightly integrates the open-source Piccolo AI ecosystem with an automated pipeline that generates deployable firmware artifacts, performs hardware-aware model compilation, and supports over-the-air (OTA) deployment. The system supports multiple lightweight model classes, including classical machine-learning algorithms and neural networks, and provides built-in on-device profiling tools to evaluate inference latency and memory footprint under realistic execution conditions. Experimental results demonstrate clear trade-offs between model complexity and deployability on a microcontroller, showing that classical models offer strong real-time performance while lightweight neural networks require careful resource management. Rather than proposing new learning architectures, the current work mainly focuses on system-level automation, deployability, and enabling researchers and developers to rapidly iterate on models and evaluate them directly on target hardware. Although demonstrated on the WeBe Band platform, the workflow is designed to be extensible to other ML-powered edge devices.

0.34

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.59
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

cs.LG ·2026-08-20 ·Anton Lambrecht, Reda El Hail, Xianjun Jiao, Pieter Crombez, Dominique Schreurs +3 more
similarity 0.59
Abstract · This paper has been submitted to IEEE Access Journal and is currently undergoing review

Despite their growing importance for contact-free radio frequency (RF) based healthcare monitoring, different radio technologies such as frequency-modulated continuous wave (FMCW) radar, impulse radio ultra-wideband (IR-UWB), and Wi-Fi sensing are rarely compared under identical deployment conditions, as existing studies typically differ in hardware, datasets, and evaluation methodologies. In addition, the performance of ceiling-mounted radars, despite their practical deployment and cost advantages in healthcare environments, remain underexplored. Therefore, this paper presents a controlled comparison and analysis of ceiling-mounted FMCW, IR-UWB, and Wi-Fi sensing using synchronized recordings from 20 participants across six room layouts. All technologies are evaluated with the same convolutional neural network (CNN) on both a fine-grained 10-class human activity recognition (HAR) task and a coarse 4-class sleep monitoring task. IR-UWB achieves the highest cross-subject activity recognition performance (89.0% macro F1), while FMCW generalizes best to unseen room layouts (83.8% macro F1). For sleep monitoring, all technologies exceed 92% macro F1 in unseen environments. The results reveal a fundamental trade-off between recognition performance and environmental robustness, which can be explained through differences in range resolution, antenna diversity, Doppler resolution, and spatial information retention. These findings provide practical guidelines for the design of healthcare-oriented RF sensing systems.

0.24

When Clean Signals Are Not Enough: Detecting Structural Ambiguity for Safe Wearable Stress Classification

cs.AI ·2026-08-19 ·Saba A. Farahani, Hung Cao, Amir M. Rahmani
published similarity 0.57
Abstract · 4 pages, 3 figures, 1 table. Accepted at the 2026 IEEE 22nd International Conference on Body Sensor Networks (BSN 2026)

Wearable stress classifiers can achieve strong average performance while failing completely for a particular individual. On WESAD, a Random Forest reaches 93.0% mean accuracy yet yields F1 = 0 for Subject 14, whose cross-signal coupling weakens near stress onset. We call this structural ambiguity: individually plausible physiological channels form an inter-signal pattern that is poorly supported by the person's non-stress reference. We introduce the Individual Conformal Coupling Monitor (ICCM), a lightweight and transparent pre-inference monitor that quantifies subject-specific coupling divergence and routes each window to classify, defer, or abstain without retraining the downstream classifier. Across WESAD (N = 15) and Stress-Predict (N = 35), full-cohort Pearson associations between ambiguity and accuracy are negative (r = -0.607, p = 0.016; r = -0.412, p = 0.014). Robustness analyses temper this finding: rank correlations are not significant, and the WESAD association disappears when Subject 14 is removed. ICCM changes false-positive counts from 29 to 27 and 94 to 92, although neither paired change is significant. It withholds 3 of Subject 14's 21 stress windows but does not repair the missed-stress failure. These results position ICCM as an interpretable signal of unsupported physiology and individual failure, rather than a stand-alone safety guarantee.

0.20

What the Sleeve Feels: Explainable Machine Learning for Textile Pressure-Based Postural Screening

cs.AI ·2026-10-07 ·Limon Bin Hossain, Md Sadib Rahman Ananta
similarity 0.57
Abstract

Pressure-sensing smart textiles convert body-surface contact into a dense, image-like signal closely tied to posture and movement, making them a promising low-cost route to wearable posture screening. Realizing that promise, however, requires more than classification accuracy: a deployable system must generalize to wearers unseen during training, expose the physical evidence behind its decisions, and tolerate the small donning offsets that occur whenever a garment is removed and re-worn. This paper addresses these three requirements jointly using a knitted piezoresistive sleeve worn on the forearm as a testbed. We regroup fine-grained everyday activities into three coarser screening categories (neutral, potentially undesirable, and functional or transitional), engineer 29 interpretable pressure-distribution features spanning global intensity, spatial center of pressure, quadrant asymmetry, distribution complexity, and short-horizon temporal change, and evaluate under a strict subject-wise split. A tuned XGBoost classifier reaches 0.818 accuracy, 0.788 balanced accuracy, and 0.801 macro F1 on unseen test subjects, with tight frame-level bootstrap 95% intervals of about plus-minus 0.01 and a subject-to-subject standard deviation near 0.06 under leave-one-subject-out cross-validation. A simple 2D-CNN baseline trained on raw frames achieves broadly similar performance, showing that hand-engineered features are not left behind by a learned spatial representation on this task. SHAP-based explanation, a feature-group ablation, per-activity error analysis inside the pooled undesirable class, class-mapping sensitivity, and a simulated donning-rotation stress test together locate what the model relies on, where it degrades, and why, directly targeting the generalization, interpretability, and robustness gaps that determine whether such a system is deployable.

0.25

From Least Squares to Deep Learning: Benchmarking Indoor Positioning on the HYMN Multi-Technology Dataset

eess.SP ·2026-09-22 ·Paul Schwarzbach, Muhammad Ammad
code/data similarity 0.56
Abstract

Indoor positioning benchmarks rarely co-locate multiple technologies with high-accuracy ground truth, limiting cross-method and cross-technology comparison. We evaluate four range-based positioning methods on fused Ultra-wideband, Bluetooth Low Energy, and WiFi ranges recorded at 48 reference points in an industrial facility with available ground truth. The evaluated methods range from least-squares positioning, with and without robust weighting, through a Bayesian grid filter to a ResNet regressor that we report under two protocols, interpolation and spatial generalisation. Per-technology ranging quality spans roughly two orders of magnitude, which caps any geometry-based solver that weighs anchors equivalently. On fused input the grid filter is competitive with deep learning on median error, while the ResNet's advantage concentrates on the upper tail. Holding reference points out of training increases the learned regressor's median error several-fold, exposing a spatial-generalisation penalty invisible under random splits. The dataset and evaluation code are publicly available.

0.20