CS Paper Radar

When Clean Signals Are Not Enough: Detecting Structural Ambiguity for Safe Wearable Stress Classification

Saba A. Farahani, Hung Cao, Amir M. Rahmani

cs.AI ·submitted 2026-08-19 00:04 UTC · v1
published

Abstract

Wearable stress classifiers can achieve strong average performance while failing completely for a particular individual. On WESAD, a Random Forest reaches 93.0% mean accuracy yet yields F1 = 0 for Subject 14, whose cross-signal coupling weakens near stress onset. We call this structural ambiguity: individually plausible physiological channels form an inter-signal pattern that is poorly supported by the person's non-stress reference. We introduce the Individual Conformal Coupling Monitor (ICCM), a lightweight and transparent pre-inference monitor that quantifies subject-specific coupling divergence and routes each window to classify, defer, or abstain without retraining the downstream classifier. Across WESAD (N = 15) and Stress-Predict (N = 35), full-cohort Pearson associations between ambiguity and accuracy are negative (r = -0.607, p = 0.016; r = -0.412, p = 0.014). Robustness analyses temper this finding: rank correlations are not significant, and the WESAD association disappears when Subject 14 is removed. ICCM changes false-positive counts from 29 to 27 and 94 to 92, although neither paired change is significant. It withholds 3 of Subject 14's 21 stress windows but does not repair the missed-stress failure. These results position ICCM as an interpretable signal of unsupported physiology and individual failure, rather than a stand-alone safety guarantee.

Comment
4 pages, 3 figures, 1 table. Accepted at the 2026 IEEE 22nd International Conference on Body Sensor Networks (BSN 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

ReliaGate: Reliability Routing for Low-Stakes Wearable Stress Prediction

cs.LG cs.HC ·2026-08-16 ·Jaden Moon, Yu Wu, Arvind Pillai, Andrew Campbell
published similarity 0.70
Abstract · Accepted at WellComp 2026, held with UbiComp/ISWC 2026. 7 pages, 4 tables, and 1 figure. To appear in UbiComp Companion '26. ACM DOI: 10.114…

We study when a wearable stress system should surface a prediction rather than change it. In low-stakes reflection and summary settings, aggregate accuracy is insufficient because withholding can reduce error while leaving some people with little or no information. We formulate fixed-label reliability routing: after a locked classifier emits a protocol-defined stress/non-stress label, a post-hoc gate surfaces that unchanged label or withholds it as unavailable. ReliaGate assembles established confidence, signal-quality/trust, agreement, train-standardized atypicality, and train-fitted geometry cues into a post-hoc correctness score. We evaluate four wearable datasets using subject-disjoint folds, validation-selected routing, paired held-out-subject intervals, and pooled and per-subject analyses. WESAD point estimates favored ReliaGate, UBFC-Phys primary coverage/risk intervals favored ReliaGate, and E4 checks were mixed. ReliaGate provides an operational framework for studying surfaced-label error, output availability, and accepted-output distribution across subjects, without revising labels or providing clinical or finite-sample risk guarantees.

0.20

Electrodermal Activity (EDA) for Stress Detection: A Comprehensive Survey and Benchmark

eess.SP ·2026-09-18 ·Gang Liu, Zixiong Ning
surveybenchmark similarity 0.60
Abstract · 19 pages, 5 figures, 7 tables

Electrodermal activity (EDA) is widely used for pervasive stress monitoring because of its sensitivity to sympathetic arousal and its computational efficiency. However, research remains fragmented: studies concentrate on a small subset of available datasets, preprocessing and evaluation protocols are inconsistent, and widely adopted methodological conventions remain unvalidated. Existing reviews summarize these practices without evaluating them under a common protocol. To bridge these gaps, this paper presents a comprehensive survey and benchmark for EDA-based stress detection. We review the technical pipeline from preprocessing to modeling and compile 26 public datasets and 22 representative unimodal studies to inform future dataset selection and methodological design. Under a subject-independent protocol spanning five diverse datasets, we benchmark decomposition, filtering, and channel-input choices alongside a broad range of machine learning (ML) and deep learning (DL) models in both in-domain and cross-domain transfer settings. Our results provide the first multi-dataset validation of cvxEDA, the default decomposition method, show that feature-based ML outperforms end-to-end (E2E) DL, and identify ecological validity as a key factor in cross-domain transfer. We conclude with directions toward robust, data-efficient, and trustworthy deployment.

0.22

SOTER: A Generative Time-Series Foundation Model for Wearable Human Physiological Signals

cs.LG cs.AI ·2026-09-15 ·Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
similarity 0.59
Abstract

Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichannel, irregularly sampled, noisy, and governed by coupled continuous-time dynamics spanning distinct spectral scales. We present SOTER, a generative foundation model for wearable physiological time series that unifies cross-channel coupling, spectrum-guided expert specialization, and continuous-time latent evolution within a single pre-training framework. SOTER combines a spatial feature-aware backbone that models inter-signal dependencies, a power spectral density (PSD)-guided mixture-of-experts layer that routes representations to experts associated with fixed spectral bands through an inspectable, non-learned rule, and a neural controlled differential equation decoder that supports prediction and imputation at arbitrary timestamps. We pre-train SOTER on 226 billion time points from five public physiological datasets and evaluate the same pre-trained model across out-of-distribution zero-shot forecasting, frozen-encoder linear-probe classification, and continuous-time imputation on wearable benchmarks. SOTER achieves the best RMSE on 4 of 6 datasets and the best MAE on 5 of 6 in zero-shot forecasting, the highest average Macro-AUROC in classification, and the lowest imputation error on all six datasets at 75% missingness. It further remains robust to additive acquisition noise, matching or surpassing baselines evaluated on clean inputs even under the strongest corruption. These results indicate that domain-specialized foundation models for wearable physiology benefit from jointly modeling channel structure, spectral scale, and continuous-time dynamics.

0.46

BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker

cs.AI cs.IR ·2026-09-03 ·Seyed Mahmoud Sajjadi Mohammadabadi
benchmark similarity 0.59
Abstract

Cardiac, neural, behavioral, and speech measurements from wearable and mobile devices provide partial, noise-sensitive views of physiological state. BioSync combines these measurements into the \textbf{BioSync Index (BSI)}, a continuous composite digital biomarker defined under the BEST framework. The model applies multi-head self-attention to modality tokens and adds a linear branch whose hypothesis class includes standard feature concatenation. This architecture is motivated by latent-variable measurement theory and by the possibility that joint observations contain information unavailable from individual modalities. We evaluated BioSync on two literature-informed synthetic cohorts: a four-modality cognitive-decline cohort using HRV, EEG, actigraphy, and speech, and a metabolic-autonomic cohort structured around the public AI-READI wearable schema. In the cognitive cohort, BioSync and concatenation obtained AUCs of 0.928 and 0.926, respectively. In the metabolic cohort, BioSync obtained accuracy/F1 of 0.764/0.766, compared with 0.756/0.758 for concatenation. The BSI correlated with latent severity in both cohorts ($r=0.91$ and $r=0.68$). A pure-attention ablation obtained cognitive-cohort AUC 0.911, locating the increase to 0.928 in the combined wide-and-deep architecture. With matched modality-dropout training, BioSync led concatenation at five of six cognitive-cohort corruption rates and at the highest metabolic-cohort rate. Its cognitive-cohort AUC was also higher than five published digital-biomarker reference values, although differences in datasets and tasks preclude a controlled benchmark claim. Comparison with single-modality, early-fusion, and late-fusion designs across six prespecified criteria identifies the model's computational properties; validation on real cohorts remains necessary.

0.17

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.59
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.59
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

When Temporal Perturbations Act Like Sensor Biases: Label-Free Auditing of Wearable Activity Recognizers

cs.LG cs.AIcs.CR ·2026-09-24 ·Qingyu Wu, Yuan Wei, Renju Liu, Hua Cheng
similarity 0.58
Abstract

Wearable human-activity recognition (HAR) models operate across sensors, subjects, and backbones, yet a smooth waveform may appear temporal while exploiting a persistent sensor offset primarily. We introduce SpectrumAudit, a label-sealed audit that fits a phase-randomized full-window stimulus on calibration windows from subjects held out from training and testing. After selection, it replays its exact DC projection and budget-constrained zero-mean residual on the same frozen victim without refitting. Across 27 victims from three datasets and three backbones, the selected waveforms cause 2.87-40.83-point three-phase robust accuracy losses. Under this replay budget, DC is more damaging than AC on 24/27 victims and recovers at least 90% of the full drop on 22/27; all 5 failures occur on WISDM. In a held-out UTD-MHAD check, the selected waveform causes 13.49-pp accuracy and 11.68-pp macro-F1 losses, versus -0.66 pp for matched random changes. The audit diagnoses offset versus zero-mean variation under a common peak-budget cap. The code will be released upon acceptance.

0.34

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.58
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32