CS Paper Radar

Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project

Luciano Bozzi, Christian Celidonio, Umberto Nuzzi, Massimo Biagini, Stefano Cherubin, Asbjørn Djupdal, Tor Andre Haugdahl, Andrea Aliverti, Alessandra Angelucci, Giovanni Agosta, Gerardo Pelosi, Paolo Belluco, Samuele Polistina, Gaia Strada, Luigi Sossi Ortega, Alexandra-Ioana Albu, Riccardo Volpi, Luigi Malagò, Michael Schneider, Xabier Eguiluz, Haritz Saiz, María Viqueria

cs.ET cs.AIcs.ARcs.CRcs.HCcs.LG ·submitted 2026-11-15 18:41 UTC · v1
publishedbenchmark

Abstract

The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: $\mathrm{Accuracy}=0.901\!\pm\!0.023$, $\mathrm{F1}=0.920\!\pm\!0.019$), while a feature-based Transformer attains the highest AUC ($0.963\!\pm\!0.025$), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.

Comment
Pre-print version
DOI
10.1016/j.micpro.2026.105355

Closest papers

Nearest neighbours by meaning across the whole index.

What the Sleeve Feels: Explainable Machine Learning for Textile Pressure-Based Postural Screening

cs.AI ·2026-10-07 ·Limon Bin Hossain, Md Sadib Rahman Ananta
similarity 0.63
Abstract

Pressure-sensing smart textiles convert body-surface contact into a dense, image-like signal closely tied to posture and movement, making them a promising low-cost route to wearable posture screening. Realizing that promise, however, requires more than classification accuracy: a deployable system must generalize to wearers unseen during training, expose the physical evidence behind its decisions, and tolerate the small donning offsets that occur whenever a garment is removed and re-worn. This paper addresses these three requirements jointly using a knitted piezoresistive sleeve worn on the forearm as a testbed. We regroup fine-grained everyday activities into three coarser screening categories (neutral, potentially undesirable, and functional or transitional), engineer 29 interpretable pressure-distribution features spanning global intensity, spatial center of pressure, quadrant asymmetry, distribution complexity, and short-horizon temporal change, and evaluate under a strict subject-wise split. A tuned XGBoost classifier reaches 0.818 accuracy, 0.788 balanced accuracy, and 0.801 macro F1 on unseen test subjects, with tight frame-level bootstrap 95% intervals of about plus-minus 0.01 and a subject-to-subject standard deviation near 0.06 under leave-one-subject-out cross-validation. A simple 2D-CNN baseline trained on raw frames achieves broadly similar performance, showing that hand-engineered features are not left behind by a learned spatial representation on this task. SHAP-based explanation, a feature-group ablation, per-activity error analysis inside the pooled undesirable class, class-mapping sensitivity, and a simulated donning-rotation stress test together locate what the model relies on, where it degrades, and why, directly targeting the generalization, interpretability, and robustness gaps that determine whether such a system is deployable.

0.25

A Rapid Pipeline for Training and Deploying ML Models on WeBe Band

cs.AI cs.LGcs.PF ·2026-09-24 ·Ehsan Kourkchi, Asmita Asmita, Houman Homayoun, Mahdi Eslamimehr
publishedcode/data similarity 0.63
Abstract

Developing optimized machine-learning algorithms for edge devices with limited computational and memory resources is challenging, time-consuming, and highly dependent on device-specific constraints. In this work, we streamline an edge ML workflow to enable rapid development, optimization, and deployment of machine-learning (ML) models directly on the WeBe Band, a wrist-worn wearable device designed for multimodal physiological data monitoring. The proposed system automatically generates hardware-efficient ML models that can be easily integrated into the WeBe core firmware, supporting AutoML, hardware-aware quantization, and performance profiling to build models that meet desired latency targets while remaining compatible with device memory and power limitations. The proposed framework tightly integrates the open-source Piccolo AI ecosystem with an automated pipeline that generates deployable firmware artifacts, performs hardware-aware model compilation, and supports over-the-air (OTA) deployment. The system supports multiple lightweight model classes, including classical machine-learning algorithms and neural networks, and provides built-in on-device profiling tools to evaluate inference latency and memory footprint under realistic execution conditions. Experimental results demonstrate clear trade-offs between model complexity and deployability on a microcontroller, showing that classical models offer strong real-time performance while lightweight neural networks require careful resource management. Rather than proposing new learning architectures, the current work mainly focuses on system-level automation, deployability, and enabling researchers and developers to rapidly iterate on models and evaluate them directly on target hardware. Although demonstrated on the WeBe Band platform, the workflow is designed to be extensible to other ML-powered edge devices.

0.34

On-device Detection of Wearer-induced NLOS on Chest-worn UWB Tags: Machine Learning, Link Indicators, or Both?

cs.LG ·2026-10-30 ·Markus Gallacher, Vu Anh Minh Le, Matteo Trobinger, Davide Vecchia, Carlo Alberto Boano +1 more
similarity 0.60
Abstract · Submitted to ACM Transactions on Sensor Networks

Ultra-wideband (UWB) enables high-accuracy distance estimation (ranging), but performance degrades in non-line-of-sight (NLOS) conditions. When UWB tags are worn, the human body inevitably causes a wearer-induced NLOS (WNLOS), yielding significant errors; still, despite its relevance, WNLOS remains understudied. Moreover, WNLOS detection typically must occur on-device at the tag, requiring classification accuracy to be balanced against tight runtime and energy constraints often hard to meet with machine learning (ML) -- the dominating NLOS classification approach. Meanwhile, UWB radio link indicators (LI) offer a faster and lightweight alternative that has rarely been explored. We study existing on-device ML and LI classifiers when applied to WNLOS, and propose novel hybrid ones exploiting their complementarity. We focus on chest-worn tags and analyze 21 classifiers on a dataset of 1.5 million samples across channels, PHY settings, environments, subjects, and orientations. Results show that while all of them achieve good classification accuracy, relative performance, including ranging errors due to misclassification, depends heavily on channel and PHY configuration. Runtime and energy efficiency also vary dramatically; some techniques offer marginal accuracy gains while consuming up to 39.6x more energy. Therefore, we also introduce a recommender tool to identify optimal classifiers under user-defined constraints, publicly released with our dataset.

0.26

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.58
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

WearableQA: A Benchmark for Health Reasoning over Real-World Wearable Data

cs.CL ·2026-09-04 ·Ji Soo Lee, Xilun Chen, Pierce Chuang, Ashish Shenoy, Jason Wei +3 more
benchmarkcode/data similarity 0.58
Abstract

Recent advances in wearable sensing enable continuous monitoring of physiological and behavioral signals, yet existing benchmarks rarely evaluate whether AI systems can reason over a real user's longitudinal wearable record. We introduce WearableQA, a benchmark comprising 4,084 10-option multiple-choice questions constructed from the wearable time series, blood biomarkers, and demographics of 200 real users, each with up to 500 days of daily measurements. WearableQA preserves authentic wearable distributions that include device noise and inter-individual variability. To evaluate distinct reasoning capabilities, we introduce 16 question types organized along two complementary axes: data versus health reasoning, which distinguishes computation over longitudinal measurements from physiological interpretation; and single- versus cross-signal reasoning, which separates reasoning about individual signals from the integration of multiple signals. To construct reliable questions at scale, we adopt a dual-grounding framework that combines literature-grounded physiological findings with statistically validated population-grounded physiological patterns. This enables the capture of meaningful relationships observed in real-world wearable data. Evaluation of 14 proprietary and open-source LLMs demonstrates that WearableQA effectively differentiates model capabilities, with performance ranging from 19.6% to 72.9% against a 10% chance baseline. Moreover, WearableQA remains far from solved: most models achieve accuracies below 60%. Overall, WearableQA provides a realistic and diagnostic benchmark for evaluating LLM reasoning over real-world wearable data.

0.18

Edge AI on Constrained Devices for Binary Sleep-Wake Classification in Dynamic Environments

cs.LG ·2026-09-24 ·Stefan Reitmann, Lena Oden
similarity 0.57
Abstract

This paper presents an Edge AI-based system for detecting sleep and wake states in non-stationary mobile environments using resource-constrained embedded hardware. Conventional approaches relying on accelerometer-based activity metrics are highly susceptible to motion and vibration artifacts and are limited by strict compute and energy budgets of wearable and IoT devices. To address these challenges, a multimodal pipeline is designed and implemented on an ESP32-S3 microcontroller. The system combines inertial sensing for head movement analysis and visual pose classification. A dual-core architecture with FreeRTOS enables parallel execution of real-time data acquisition and on-device inference. Sleep detection follows a two-stage strategy: low-movement detection over a temporal window, followed by visual validation of poses. Experimental results show accuracies of 96.5% for motion-based detection and 89% for pose classification, yielding robust binary sleep-wake classification. Field tests confirmed feasibility in representative mobile scenarios. The results demonstrate that privacy-preserving, local sleep detection is achievable on edge hardware through careful co-design, while highlighting limitations in sensing intrusiveness, dataset scale, and system integration.

0.26

Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

cs.LG ·2026-10-22 ·Ihsan Ul Haq, James Brusey, Farnad Nasirzadeh, Chandan Karmakar
publishedbenchmark similarity 0.56
Abstract · Accepted at IEEE BSN 2026

Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95 %, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9 % to 88.7 % (mean 77.5 %), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30 % of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment

0.26

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.56
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11