CS Paper Radar

Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

Ihsan Ul Haq, James Brusey, Farnad Nasirzadeh, Chandan Karmakar

cs.LG ·submitted 2026-10-22 12:16 UTC · v1
publishedbenchmark

Abstract

Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95 %, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9 % to 88.7 % (mean 77.5 %), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30 % of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment

Comment
Accepted at IEEE BSN 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

cs.AI cs.LG ·2026-08-16 ·Seungyeol Baek, Yoonbyung Chai, Yonghyeon Lee, Sungjoon Choi, Sungho Suh
published similarity 0.67
Abstract · 6 pages, 2 figures. ACM International Symposium on Wearable Computing (ISWC) 2026

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.

0.58

A Group-Aware Comparative Study of Classical Machine Learning and Deep Learning Methods for Sensor-Based Human Activity Recognition

cs.LG cs.AIeess.SP ·2026-10-08 ·Wahyu Pebrianto
similarity 0.62
Abstract

Human Activity Recognition (HAR) using wearable or smartphone inertial sensors is commonly evaluated with both classical machine learning and deep learning methods. However, reported performance can be strongly affected by sensor modality, dataset characteristics, and data-splitting strategy. This study presents a controlled comparative evaluation of four classical machine learning models and four deep learning models on two public HAR datasets, UCI-HAR and KU-HAR. Three sensor modalities were considered: accelerometer (ACC), gyroscope (GYRO), and their combination (ACC+GYRO). Classical machine learning models used handcrafted statistical features, while deep learning models operated directly on raw sensor sequences. The primary evaluation employed five-fold StratifiedGroupKFold cross-validation, with subject- or participant-level grouping to prevent group overlap between training and test folds. Macro-F1 was used as the primary performance metric. The results show that deep learning did not consistently outperform classical machine learning. On UCI-HAR, the evaluated deep learning models achieved slightly higher macro-F1 values, whereas on KU-HAR, LightGBM achieved 0.857 compared with 0.828 for the highest-performing evaluated deep learning model. Regarding sensor modality, the combined ACC+GYRO configuration generally outperformed ACC or GYRO alone on both datasets. The evaluation protocol also had a substantial effect: for CNNBiLSTMAttn with ACC+GYRO, random splitting increased macro-F1 by 0.033 on UCI-HAR and 0.093 on KU-HAR compared with grouped evaluation. These findings highlight the importance of model family, sensor modality, dataset characteristics, and group-aware evaluation when assessing sensor-based HAR systems.

0.14

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.59
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.58
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30

REFIT: Recognize, Fix, and Test Wearable Sensor Placement Shifts without Labels

cs.LG cs.HC ·2026-10-06 ·Bangxun Tang
similarity 0.58
Abstract · 25 pages, 5 figures, 14 tables. Under review

We present REFIT, an input calibration for frozen activity-recognition models whose inertial sensors are worn differently at deployment than in training. When users move a watch to the other wrist or put a strap sensor back on turned, the model sees the same motion on changed axes. REFIT undoes such shifts without labels or retraining. It describes them by families of axis transforms, such as reflections and rotations, and fits each family to the user's data so that simple statistics match those of the training data. The family that removes most of the mismatch names the shift. REFIT fixes the shift by applying the best member of that family before the frozen model and re-estimating its normalization statistics. It tests the fixed model with a label-free accuracy estimate and asks the user to re-wear the sensor when it is low. Experiments on real left/right sensor pairs and on real and simulated re-attachment show that REFIT outperforms label-free test-time adaptation methods on every dataset and restores most of the accuracy lost to re-attachment. It names injected shifts far more reliably than a confidence-based selector. After a correction over all signed permutations of the axes, the estimate separates successful from failed corrections.

0.24

An Effective, Reliable, and Robust Framework for Human Activity Recognition Using Wearable Sensors

cs.LG ·2026-09-29 ·Nafees Ahmad, Ho-fung Leung, Muhammad Adil Abid, Sadia Shakil
similarity 0.58
Abstract

Human Activity Recognition (HAR) through wearable sensors greatly improves the quality of human life through its multiple applications. For HAR, multi-sensor channel information is vital for optimal performance. Current work states that applying an attention neural network to prioritize discriminatory sensor channels helps the model classify activity more precisely. However, obtaining discriminatory information from multisensory channels is not always trivial, such as when collecting data from older hospitalized patients. In this context, existing HAR methods struggle to classify activities, particularly activities with similar natures. Moreover, HAR models predominantly suffer from overfitting due to the small size of available datasets, which leads to poor performance. Data augmentation (DA) is a viable solution to this problem. However, available DA methods have various drawbacks, including the possibility of being domain-dependent, resulting in distorted models for test sequences. To address these HAR problems, we propose a novel framework, ALAE-TAE-CutMix+, which focuses on two aspects. First, it enhances the latent information across each sensor channel and learns to exploit the relation among multiple latent features and the ongoing activity. Consequently, the discriminatory feature representations of each activity is enriched. Second, a new augmentation strategy is introduced to address the shortcomings of existing multi-sensor channel data augmentation. We then extend the framework to create a further enhanced version, namely ALAE-CIE-TAE-CutMix+, which learns to capture the interactions between the features of each pair of sensor channels. We find that although the first framework performs slightly better than the latter, the latter is nonetheless more reliable and robust. Both frameworks significantly outperform SOTA approaches on the four HAR datasets from diverse domains.

0.35

DiffusionRef-IMU: Guide-Anchored Residual Diffusion for Cross-Location Inertial Measurement Unit Translation

cs.LG ·2026-11-06 ·M. M. Golam Hafiz, Safia Akter Simi, Md. Rakibul Islam, M. F. Mridha
similarity 0.58
Abstract · 18 pages, 5 figures, 6 tables

Cross-location variation in wearable inertial measurement unit (IMU) signals complicates learning when measurements from a desired target body location are unavailable. This study proposes DiffusionRef-IMU, a two-stage cross-location translation framework in which a deterministic Direct network first estimates the target signal and a guide-anchored residual diffusion model refines only the remaining target discrepancy. The evaluation comprises five subject-disjoint activity-location composition-held-out folds, capacity-matched deterministic and flow-based residual baselines, source-only activity conditioning, computational ablation, and true zero-shot evaluation on two independent datasets. DiffusionRef-IMU with 16-step deterministic DDIM achieved a mean nRMSE of 0.087538 +/- 0.004922, compared with 0.090262 for Direct, 0.088847 for deterministic residual refinement, and 0.088417 for eight-step CompFlow, and outperformed each baseline in all five folds. Four-step DDIM retained a mean nRMSE of 0.087820 at 47.62 ms per window, providing a favourable quality-computation trade-off. Replacing ground-truth activity conditioning with a source-only activity predictor (macro-F1 0.8473) increased 16-step DiffusionRef nRMSE only to 0.088190. True zero-shot evaluation produced mixed results: DiffusionRef was marginally favourable on Grouvel2025 but remained worse than Direct on Saldaña2025. Overall, guide-anchored residual diffusion improves controlled cross-location reconstruction while revealing clear limits in zero-shot external transfer.

0.28

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.58
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.