CS Paper Radar

DiffusionRef-IMU: Guide-Anchored Residual Diffusion for Cross-Location Inertial Measurement Unit Translation

M. M. Golam Hafiz, Safia Akter Simi, Md. Rakibul Islam, M. F. Mridha

cs.LG ·submitted 2026-11-06 11:15 UTC · v1

Abstract

Cross-location variation in wearable inertial measurement unit (IMU) signals complicates learning when measurements from a desired target body location are unavailable. This study proposes DiffusionRef-IMU, a two-stage cross-location translation framework in which a deterministic Direct network first estimates the target signal and a guide-anchored residual diffusion model refines only the remaining target discrepancy. The evaluation comprises five subject-disjoint activity-location composition-held-out folds, capacity-matched deterministic and flow-based residual baselines, source-only activity conditioning, computational ablation, and true zero-shot evaluation on two independent datasets. DiffusionRef-IMU with 16-step deterministic DDIM achieved a mean nRMSE of 0.087538 +/- 0.004922, compared with 0.090262 for Direct, 0.088847 for deterministic residual refinement, and 0.088417 for eight-step CompFlow, and outperformed each baseline in all five folds. Four-step DDIM retained a mean nRMSE of 0.087820 at 47.62 ms per window, providing a favourable quality-computation trade-off. Replacing ground-truth activity conditioning with a source-only activity predictor (macro-F1 0.8473) increased 16-step DiffusionRef nRMSE only to 0.088190. True zero-shot evaluation produced mixed results: DiffusionRef was marginally favourable on Grouvel2025 but remained worse than Direct on Saldaña2025. Overall, guide-anchored residual diffusion improves controlled cross-location reconstruction while revealing clear limits in zero-shot external transfer.

Comment
18 pages, 5 figures, 6 tables

Closest papers

Nearest neighbours by meaning across the whole index.

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.60
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

0.26

Two-Stage Personalized Gait Phase Estimation in Stroke Survivors During Exoskeleton-Assisted Walking: An Offline Feasibility Study

cs.RO ·2026-09-14 ·Hyungseok Ryu, Pilwon Hur
similarity 0.59
Abstract · 11 pages

This study evaluated personalized gait phase estimation for stroke survivors using functional inertial measurement unit (IMU) alignment and two-stage sequential adaptation of models pre-trained on healthy gait. The estimator used signals from a thigh-mounted IMU. Heel force-sensitive resistor measurements provided reference phase labels for offline adaptation and evaluation. Stage 1 established a distillation-regularized participant-specific model, and Stage 2 performed conditional refinement using low-rank adaptation. Long Short-Term Memory (LSTM), Temporal Convolutional Network (TCN), and Transformer models were evaluated in five stroke survivors walking with a powered knee exoskeleton using leave-one-subject-out hyperparameter selection and sequential test-then-adapt Stage 2 replay. Relative to the non-adapted baselines, Stage 1+2 reduced the mean participant-wise phase root mean square error by 84.2%, 77.0%, and 60.7%, respectively. The Transformer achieved the lowest final error (2.90 +- 1.13$% of the gait cycle) and heel-strike timing error (23.7 +- 4.5ms). Policy-specific ablations showed that every-cycle updates generally produced the lowest or near-lowest error, whereas conditional updating reduced the update frequency with small accuracy differences. After personalization, alignment produced model-dependent changes in phase error while preserving or improving heel-strike detection and reducing heel-strike timing error for the LSTM and Transformer. Concurrent embedded tests showed that the TCN and Transformer maintained 100-Hz inference during Stage 2 updates without deadline misses, whereas the LSTM missed the 10-ms deadline in 6.6% of inferences. All updates completed within 0.8s. These results support the offline feasibility and embedded computational timing of the proposed framework for exoskeleton-assisted walking.

0.20

DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution

eess.SP ·2026-09-15 ·Fan-Yi Hsu, I Chiu, Kuan-Chen Wang, Sheng-Yu Peng, Yu Tsao
published similarity 0.58
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from low-sampling-rate inputs. While recent SR methods based on discriminative neural networks have shown strong performance, their robustness under distribution shift remains uncertain, which poses a key challenge for real-world deployment. In this study, we propose DiSR-ECG, a residual shifting conditional diffusion framework for robust ECG SR. The model integrates residual shifting with Mamba-based temporal modeling and conditional guidance to enable accurate multi-lead reconstruction. Experiments on two large-scale ECG databases, PTB-XL for in-domain evaluation and Chapman Shaoxing for cross-dataset evaluation, demonstrate that DiSR ECG achieves state-of-the-art performance in both settings, with particularly strong generalization under distribution shift. These results highlight the potential of DiSR-ECG to provide reliable and clinically applicable ECG reconstruction for real-world monitoring.

0.25

Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

cs.LG ·2026-10-22 ·Ihsan Ul Haq, James Brusey, Farnad Nasirzadeh, Chandan Karmakar
publishedbenchmark similarity 0.58
Abstract · Accepted at IEEE BSN 2026

Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95 %, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9 % to 88.7 % (mean 77.5 %), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30 % of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment

0.26

HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition

cs.LG cs.AIeess.SPstat.ML ·2026-11-13 ·Yasaman Mohammadpour, Pouya Shaeri
publishedcode/data similarity 0.58
Abstract · Extended version of a paper accepted at IEEE BigData 2026. Code: https://github.com/yasamanmohammdpour/HeteroWear

Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.

0.30

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.57
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

Calibration-free IMU-based Relative Orientation Estimation under Dynamic Human Motion

cs.RO eess.SY ·2026-10-22 ·Ruiyuan Li, Hassan Osman, Ajay Seth, Manon Kok
similarity 0.56
Abstract · 8 pages, 7 figures, 1 table. Submitted to IEEE Sensors Journal

Recent magnetometer-free inertial measurement unit (IMU) methods can reduce drift in joint motion estimation using rigid-body constraints, but they typically require pre-calibrated sensor locations, assumptions of specific joint models (e.g., hinge joints) or limited motion types, or an external reference for global orientation. Furthermore, challenges related to high-frequency impacts (e.g. at foot strikes during gait) and numerical differentiation of noisy measurements have not been explicitly addressed. We propose an extended Kalman filter that estimates relative IMU orientation and sensor location simultaneously, requiring neither offline sensor location calibration nor a global orientation anchor. A systematic simulation study shows that the quality of the relative orientation and the sensor location estimates depends on different motion-intensity sources: the joint center acceleration and the relative angular velocity, respectively. A low-pass filter (LPF) is used to mitigate real-signal outliers before applying the rigid-body constraint. When applied to the OpenSense dataset with real IMU measurements across four subjects with three lower-body joint types during walking and complex tasks including various motion types, the proposed method achieves an overall relative orientation error of 2.61°, compared with 10.40° for a baseline using offline-estimated sensor locations and 7.43° for a baseline using marker-derived sensor locations. These results show that the proposed calibration-free estimation framework handles real IMU data effectively and achieves accurate relative orientation without offline sensor location calibration.

0.16

Rotation-Invariant Multi-IMU Activity Recognition under Independent Per-Location Orientation Shifts

cs.AI cs.LG ·2026-08-16 ·Seungyeol Baek, Yoonbyung Chai, Yonghyeon Lee, Sungjoon Choi, Sungho Suh
published similarity 0.56
Abstract · 6 pages, 2 figures. ACM International Symposium on Wearable Computing (ISWC) 2026

Human Activity Recognition (HAR) with self-administered wearables, such as at-home rehabilitation and exercise monitoring, often requires reattaching inertial measurement units (IMUs) across sessions. In multi-IMU settings, this can induce independent orientation offsets across body locations, a deployment shift that conventional scalar HAR models do not structurally handle. Existing remedies rely on rotation augmentation, whose robustness depends on sampled transformations, or calibration and orientationnormalization pipelines requiring additional reference-frame assumptions or explicit procedures. We present Truly Rotation-Invariant HAR (TRI-HAR), a rotation-invariant framework that makes robustness to independent per-location IMU orientation offsets a structural model property. TRI-HAR reshapes accelerometer and gyroscope streams into triaxial vectors, applies a shared SO(3)-equivariant backbone and invariant projection to each IMU location, and fuses the resulting invariant features for activity classification. Across four multi-IMU benchmarks, TRI-HAR preserves macro-F1 under fixed independent per-location SO(3) rotations and outperforms rotation-augmented baselines under this target shift without requiring rotational augmentation.

0.58