CS Paper Radar

An Energy Efficient Wearable for Monitoring Elderly People Health

M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto, C. Marcon

eess.SP cs.CY ·submitted 2026-08-26 20:26 UTC · v1

Abstract

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

Comment
8 pages, 11 figures

Closest papers

Nearest neighbours by meaning across the whole index.

SuperSenseDoctor: A Multimodal and Contactless Agent for Health Tracking

cs.HC ·2026-08-27 ·Xuwen Zhang, Zijian Lu, Yicheng Lei, Rui Qiu, Jiale Li +3 more
similarity 0.68
Abstract · 5pages,4figures,2tables

Population aging is increasing the need to monitor older adults safely and independently at home. However, cameras, wearables, and manual checks often introduce privacy, adherence, and attention burdens that hinder sustained health monitoring. This paper presents SuperSenseDoctor, a multimodal contactless agent architecture for long-term home health tracking. The system transforms WiFi, mmWave radar, and surface temperature into a persistent human health state. The system relies on fixed decision rules to conduct continuous daily monitoring and respond to pre-defined hazards. When abnormal signals appear, event-driven reasoning analyzes only standardized evidence to produce traceable care-support measures. In this manner, SuperSenseDoctor integrates sensing, temporal state, reasoning, and action into a unified and auditable loop. The calibrated multimodal pipeline achieves 1.994 bpm mean absolute error (MAE) and 3.142 bpm root mean square deviation (RMSD) for heart rate, 0.197 bpm MAE and 0.263 bpm RMSD for respiratory rate, and 96.5% fall-recognition accuracy. The evaluation also covers 2686 one-second states across 9 chronological intervals and reaches a 96.7% criterion-level Agent checklist pass rate. These results demonstrate the feasibility of a stateful contactless sensing-to-action architecture for long-term home health monitoring.

0.21

Calibration-Free Cuffless Blood Pressure Estimation Using Multimodal ECG-PPG Fusion on a Google Pixel Watch

cs.HC ·2026-08-26 ·Jathushan Kaetheeswaran, Boyi Ma, Ali Abedi, Shehroz S. Khan, Milad Lankarany
hot direction similarity 0.61
Abstract

Inadequate blood pressure (BP) monitoring and management outside of clinical settings can worsen major cardiovascular risk factors such as hypertension. While cuff-based devices are commonly used for at-home monitoring, these devices can be inconvenient for daily use due to their sensitivity to body positions, upper-arm constrictions, and limited portability. A promising alternative is emerging in the form of consumer-grade smartwatches, where physiological signals related to cardiac activity can be used to estimate BP non-invasively and continuously across daily living conditions. In this work, we use data collected from a Google Pixel Watch in 40 participants to develop and compare several algorithm approaches for BP estimation. We found that our proposed deep learning model achieved the strongest overall performance, and that fusing smartwatch signals with demographic information improved model generalizability to unseen individuals. However, we also identified that model accuracy was not consistent across participant subgroups, with obese individuals yielding higher estimation errors than others. This study highlights the feasibility of consumer-grade smartwatches as accessible platforms for deploying robust BP estimation algorithms, though clinical reliability will require larger, more diverse populations and additional sensing modalities.

0.22

WearableQA: A Benchmark for Health Reasoning over Real-World Wearable Data

cs.CL ·2026-09-04 ·Ji Soo Lee, Xilun Chen, Pierce Chuang, Ashish Shenoy, Jason Wei +3 more
benchmarkcode/data similarity 0.60
Abstract

Recent advances in wearable sensing enable continuous monitoring of physiological and behavioral signals, yet existing benchmarks rarely evaluate whether AI systems can reason over a real user's longitudinal wearable record. We introduce WearableQA, a benchmark comprising 4,084 10-option multiple-choice questions constructed from the wearable time series, blood biomarkers, and demographics of 200 real users, each with up to 500 days of daily measurements. WearableQA preserves authentic wearable distributions that include device noise and inter-individual variability. To evaluate distinct reasoning capabilities, we introduce 16 question types organized along two complementary axes: data versus health reasoning, which distinguishes computation over longitudinal measurements from physiological interpretation; and single- versus cross-signal reasoning, which separates reasoning about individual signals from the integration of multiple signals. To construct reliable questions at scale, we adopt a dual-grounding framework that combines literature-grounded physiological findings with statistically validated population-grounded physiological patterns. This enables the capture of meaningful relationships observed in real-world wearable data. Evaluation of 14 proprietary and open-source LLMs demonstrates that WearableQA effectively differentiates model capabilities, with performance ranging from 19.6% to 72.9% against a 10% chance baseline. Moreover, WearableQA remains far from solved: most models achieve accuracies below 60%. Overall, WearableQA provides a realistic and diagnostic benchmark for evaluating LLM reasoning over real-world wearable data.

0.18

Personalized health coaching via coachable health age and counterfactual wearable trajectories

cs.LG q-bio.QM ·2026-11-05 ·Simon A. Lee, Zeinab Esmaeilpour, Menglian Zhou, Marius Guerard, Sohrab Sidhu +15 more
similarity 0.60
Abstract

Personalized health coaching requires moving beyond retrospective wearable summaries toward quantitative, actionable behavioral prescriptions. We introduce Coachable Health Age (CHA), an interpretable health-age metric built from modifiable physiological and behavioral signals passively captured by consumer wearables. Across the WEAR-ME (N=2,780), All of Us (N=22,748), and longitudinal Fitbit (N=1,464) cohorts, CHA aligns with established cardiometabolic health constructs and improves prognostic discrimination for incident cardiovascular and metabolic disease beyond age, sex, and body mass index. To enable prospective behavioral optimization, we developed Sensor World Model (SensorWM), an action-conditioned wearable world model pretrained on over 2.2 million person-weeks of longitudinal sensor data from approximately 100,000 participants. SensorWM accurately forecasts multi-week physiological responses to candidate lifestyle changes ($R^2=0.664$), outperforming generic time-series foundation models while preserving downstream clinical signal for diabetes, hypertension, and other health outcomes. Finally, we integrate CHA and SensorWM into an agentic counterfactual coaching system to synthesize personalized 12-week coaching plans. In blinded paired reviews, certified lifestyle coaches preferred counterfactual-grounded plans over plans grounded in wearable history alone for overall quality (71.4%, P < 0.001) and anticipated adherence (71.0%, P < 0.001), and board-certified clinicians judged 99.2% of counterfactual-grounded plans to meet clinical safety criteria (vs. 97.6% of comparison plans). Automated evaluations across the full cohort (N=2,780) also favored counterfactual-grounded plans. By closing the loop between longitudinal tracking, trajectory prediction, and counterfactual coaching, our framework provides a scalable path to systematically improve cardiometabolic health.

0.16

Cyber-Secure Wearable, Ultra-Low-Power Networked Sensors for Soldier Health Monitoring: Insights from the CAPSARII project

cs.ET cs.AIcs.ARcs.CR+2 ·2026-11-15 ·Luciano Bozzi, Christian Celidonio, Umberto Nuzzi, Massimo Biagini, Stefano Cherubin +17 more
publishedbenchmark similarity 0.58
Abstract · Pre-print version

The CAPSARII project advances a cyber-secure, ultra-low-power wearable platform and Internet of Battlefield Things (IoBT) framework to support real-time monitoring of military personnel and data-driven decision support. The architecture integrates smart-textile sensing, a body/squad area mesh, edge-deployed AI on secure RISC-V microcontrollers, and cloud/federated analytics for cross-mission learning and comparative studies. Two representative use cases--pilot fatigue and warfighters operating in harsh environments--guide requirements, validation, and interface design (including HUD and haptic feedback). As an initial step toward embedded models, we benchmark stress classification on a public wearable dataset: tree-ensemble baselines achieve state-of-the-art performance for accuracy and F1 (e.g., XGBoost: $\mathrm{Accuracy}=0.901\!\pm\!0.023$, $\mathrm{F1}=0.920\!\pm\!0.019$), while a feature-based Transformer attains the highest AUC ($0.963\!\pm\!0.025$), informing feature-engineering and compression choices for edge deployment. Building on these results, CAPSARII employs HW/SW co-design, model compression (pruning, quantization, distillation), and precision tuning to meet stringent energy and memory budgets; it further investigates Processing-in-Memory accelerators for future efficiency gains. A structured gap analysis highlights the remaining challenges: establishing validation standards for physiological signal quality and textile durability; achieving low-latency, scalable BAN/SAN communications under mobility and interference; and deploying hybrid lightweight/post-quantum cryptography with robust device identity and side-channel resilience on constrained endpoints. By consolidating these elements into a coherent, secure IoBT stack, CAPSARII delineates a practical roadmap from laboratory baselines to mission-ready soldier monitoring in both training and operational scenarios.

0.30

SmartBike: A Low-Power Edge IoT System for Cycling Safety and Real-Time Awareness

eess.SP ·2026-10-08 ·Sogand Hashemi, Gonçalo Sarabanda Neves Loureiro, Catarina Pereira De Freitas Lima, Lyssa Ramaut, Liesbet Van der Perre
published similarity 0.58
Abstract · 5 pages, 4 figures, 4 tables. Presented at the 46th Symposium on Information Theory and Signal Processing in the Benelux (SITB 2026), Ghent,…

Urban cycling is a sustainable mode of transportation, but cyclists remain highly vulnerable in dense traffic because of limited situational awareness and the lack of active safety assistance on conventional bicycles. This paper presents SmartBike, a low power Internet-of-Things (IoT) platform for cyclist safety, combining blind spot monitoring, rider usage detection, localization, and wireless edge-to-gateway communication. The proposed system consists of a bike-mounted IoT node and a gateway assisted monitoring interface. The node integrates three time-of-flight sensors for blind spot detection, an IMU module for motion sensing and on-board speed estimation, a GNSS module for localization, and a saddle mounted piezo-electric transducer for event-driven wake up. To satisfy the energy constraints of the IoT node, the design employs piezo-triggered activation, application specific sensing rates, and compact connectionless Bluetooth Low Energy (BLE) advertisements for low overhead transmission. The firmware is implemented in Zephyr RTOS using a lightweight state machine architecture, while the gateway performs passive BLE scanning, payload decoding, and real-time dashboard visualization. The BLE payload is reduced to 11 bytes, and power analysis shows that sensing accounts for more than 90% of the total energy budget, while wireless communication represents less overall consumption. With a 12600 mWh battery, the estimated lifetime reaches approximately 21 months under typical commuting conditions (Average 40 min per day).

0.40

Smart Insole Human Activity Recognition for Continuous Monitoring in Elderly Care

cs.LG ·2026-09-16 ·Edwin Rios, Antony Garcia, Fengpei Yuan, Xinming Huang
similarity 0.57
Abstract

Falls in older adults are often preceded by changes in mobility, balance, and postural transitions. This paper presents a wireless smart insole platform and machine-learning workflow for recognizing sitting, standing, walking, and unstable walking from plantar-pressure and inertial signals. Each insole integrates 16 active pressure-sensing locations and a six-dimensional IMU stream consisting of tri-axial acceleration and angular velocity. Data were collected from 15 healthy adults at 80~Hz and segmented into overlapping windows. Window length and candidate model families were first screened with stratified 10-fold cross-validation; the primary performance estimate was then obtained with participant-independent 5-fold Stratified Group cross-validation, ensuring that all windows from a participant remained in a single fold. Under this protocol, Histogram-Based Gradient Boosting (HGB) achieved macro-F1 scores of 0.954 and 0.959 for the left and right feet, respectively, and 0.980 with bilateral sensing. A compact 1D-CNN evaluated with the same participant-independent folds did not significantly outperform HGB ($p=0.0625$). The results show that low-profile footwear sensing can infer activity state from pressure and IMU measurements for participants unseen during training, establishing a basis for activity monitoring and fall prevention in elderly care.

0.21

Demo: Matter-Based IoMT Telemetry and Security Analysis

cs.AR cs.ETcs.RO ·2026-11-12 ·Muhammad Hassan, Masooda Bashir, Carl Gunter
similarity 0.56
Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

0.23