CS Paper Radar

Demo: Matter-Based IoMT Telemetry and Security Analysis

Muhammad Hassan, Masooda Bashir, Carl Gunter

cs.AR cs.ETcs.RO ·submitted 2026-11-12 04:22 UTC · v1

Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

Closest papers

Nearest neighbours by meaning across the whole index.

An Event-Driven Cloud-Native Wearable Analytics Framework for Real-Time Clinical Workloads

cs.DC ·2026-08-11 ·Elias Grünewald, Daniil Cherepko, Linus Gustafsson, Jakob Möhler, Oskar Rabe +5 more
code/data similarity 0.61
Abstract · Wearables, Cloud Native, Stream processing, FHIR, Clinical Decision Support

Continuous physiological monitoring using consumer-grade wearables offers a transformative opportunity for clinical care and research, yet integration remains hindered by device heterogeneity, proprietary data formats, and strict regulatory requirements. We present an event-driven, cloud-native system designed to ingest, normalize, and analyze high-frequency vital signs from wearables at scale and without vendor lock-in. The system design proposes a multi-layered microservice architecture using cluster orchestration. Data acquisition is handled via a cross-platform mobile application that leverages native health frameworks, ensuring compatibility across fragmented device ecosystems. To address interoperability, we implement an event-driven transformation pipeline using stream processing engines and specialized services to map raw measurements to the FHIR standard for medical interoperability. Our novel dependency-aware FHIR minimization scheme reduces storage overhead while maintaining lossless resource reconstruction. Furthermore, the platform integrates a modular data analytics and machine learning layer based on a medallion lakehouse architecture, supporting the full machine learning lifecycle from real-time stream processing to model serving. Performance evaluation demonstrates that the ingestion pipeline sustains 50 full ingestion requests per second with median response times under 8 ms, satisfying the low-latency requirements for real-time patient monitoring. Our open-source implementation adheres to regulatory compliance standards through role-based access control and secure service-to-service communication, providing a robust foundation for deploying wearable-based monitoring in institutional healthcare settings for clinical decision support and research workloads.

0.20

Wearable Data Profiling for NDN-Based Smart Healthcare: Performance Comparison with an IP Baseline

cs.NI ·2026-10-14 ·Mohammad R. Shakournia, Nasser Yazdani, Carlos T. Calafate
similarity 0.58
Abstract

Smart healthcare IoT requires low-latency and reliable delivery of patient data, yet IP-based communication remains host-centric and offers limited support for mobility, caching, and request aggregation. This paper evaluates a smartphone-centric Named Data Networking (NDN) approach in which a patient's smartphone aggregates sensor streams and publishes a stable latest profile under a consistent name, enabling effective in-network caching. Using ndnSIM simulations on a realistic medical IoT topology, we compare NDN and IP under identical traffic and link conditions. Results show that per-sample naming provides little benefit, but smartphone aggregation with stable naming allows NDN caching to reduce delay after cache warm-up and achieve significantly higher delivery ratios under congestion compared to IP.

0.35

Making the Telemetry Pipeline Measurable: An Edge IoT Testbed and Dataset for End-to-End Latency, Provenance, and Energy-Aware Benchmarking

cs.DC cs.NIcs.SE ·2026-10-26 ·Dimitris Gkoulis
benchmark similarity 0.58
Abstract

Edge-centric IoT systems are increasingly evaluated through sensor values or platform features, yet the telemetry pipeline itself, the sequence of sensing, serialization, message mediation, ingestion, and persistence, is rarely released as a measurable object. This limits reproducible benchmarking of timeliness, provenance, and operational cost, especially in early-stage IoT design where real deployments and high-quality open data are often unavailable. I present a measurement-first edge IoT testbed and dataset that elevate timeliness, provenance, and energy to first-class telemetry dimensions. The testbed operationalizes a role-based event-driven architecture with explicit Source-Broker-Aggregator responsibilities and a schema-governed TelemetryMessage envelope (Avro) that embeds correlation identifiers and a uniform, cross-role vocabulary of stage-level timestamps. To trace mediation effects, I extend an MQTT broker (Eclipse Mosquitto) with a plugin that annotates messages with high-precision ingress/egress timestamps. I release the dataset in a dual representation: (i) replayable raw events as compressed Avro streams and (ii) analysis-ready long-format Parquet tables partitioned for efficient query and benchmarking, generated by a deterministic raw-to-tabular transformation pipeline. The contribution is an integrated engineering artifact and dataset built from established components. The demonstration describes one deployment through latency summaries, measurement-context distributions, and energy aggregates; it does not establish a new attribution method or a controlled performance benchmark. By co-releasing heterogeneous telemetry with pipeline timing and energy signals in both replayable and queryable forms, the artifact provides a basis for reproducible exploratory analysis and subsequent benchmarking studies.

0.20

IoMT-SecAlarmBench: A Counterfactual Benchmark for Integrity Attacks in IoMT

cs.CR ·2026-08-26 ·Emmanuel C. Ugwuabonyi, Dmitri Perkins
benchmarkcode/dataunusual similarity 0.57
Abstract · 10 pages, 2 figures, 5 tables. Submitted to IEEE International Conference on Big Data (BigData) 2026. Benchmark, generator, evaluation harne…

The Internet of Medical Things (IoMT) combines clinical physiological data with cyber-system information, creating challenges in determining whether an abnormal reading reflects a genuine physiological event, a device fault, or a cyber-attack within the expected physiological range. Answering this requires counterfactual ground truth, which no existing dataset provides. We present IoMT-SecAlarmBench, a semi-synthetic benchmark that injects controlled integrity attacks into genuine coupled ECG+PPG recordings using a structured experimental design combining four attack morphologies, four severity levels, two physiological plausibility conditions, and replay attacks. Each injected window retains its cause, attack subtype, and the clean signal that would have been observed without the attack. We evaluate six detectors from five method families using threshold-independent measures and a matched false-alarm budget. Results show no method consistently detects the most difficult cases: replay attacks and low-amplitude transient spikes remain close to chance-level performance across detectors. Results also reveal a trade-off between detecting attacks and distinguishing them from sensor faults: the best-performing detector on hard cases flags fault/artifact windows at 5.3 times its false-alarm rate on normal data. Three-way classification performs poorly for genuine physiological events, and a leakage audit of a dual-modality network dataset indicates previously reported IoMT intrusion-detection performance is partly driven by identifying information. Benchmark, generation code, preprocessing, evaluation tools, and datasheet are released.

0.43

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.56
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

SmartBAN on Silicon by Structured Behavioral Modeling

cs.NI ·2026-08-29 ·Masato Yoshimi, Takahiro Ito, Kento Tanaka, Hirokazu Tanaka
published similarity 0.56
Abstract · 10 pages, 6 figures, 8 tables. Accepted for publication in IEEE Internet of Things Journal; v2 is the accepted version (revised after peer r…

Wireless body area networks (WBANs) underpin the Internet of Medical Things (IoMT). IEC/ETSI SmartBAN defines a lightweight time-division multiple access (TDMA) protocol, yet published implementations on commercial hardware remain partial. The standard specifies frame formats but leaves device-internal behavior in phase control, connection lifecycle, and slot timing unspecified. We present an operational SmartBAN realization on a commercial wireless system-on-chip (Nordic nRF54L15, Arm Cortex-M33, Zephyr RTOS) that implements initial connection, scheduled uplink, and timeout-based disconnection detection through a four-layer software architecture whose hardware abstraction layer is the intended portability boundary. Hub and Node Mealy automata supply one concrete design for the unspecified phase control and connection lifecycle, as a blueprint for the firmware's event-driven dispatch. Validation with 16 concurrent Nodes over 25 hours shows conformance across every transition the build exercises (all but one), >99.99% packet delivery, and timeout-triggered reconnection after the single observed disconnection. An analytical current model fits the measurements once it uses measured state currents; with datasheet currents it underestimates the average, mostly in the radio-off state, whose current we attribute to implementation-level overhead rather than the hardware. A same-SoC comparison with Bluetooth Low Energy (BLE) shows how each protocol departs from its schedule: SmartBAN, configured to send a fresh sample every interval instead of retransmitting, kept each Node's frame spacing within 1.1 ms of the interval but lost some frames; BLE lost none but deferred some by one or two intervals, and drew less than half SmartBAN's average current.

0.41

An Emulation Anchored Digital Twin Testbed for Cyberattack and Defense Analysis in Hospital IT OT Environments

cs.CR ·2026-08-18 ·Prashant Rawat, Ravi Kumar Bairagi, Arunima, Geeta Yadav
similarity 0.54
Abstract

Modern hospitals increasingly rely on integrated Information Technology (IT) and Operational Technology (OT) infrastructures to support critical healthcare services. However, this convergence expands the cybersecurity attack surface and makes safe validation of defensive mechanisms difficult on live systems. Existing testbeds often focus on isolated IT or OT environments and do not capture realistic cross-domain healthcare interactions. This work presents a hospital IT and OT cybersecurity testbed coupled with a digital twin for monitoring, experimentation, and validation of countermeasures. The testbed emulates a central server, Electronic Health Record (EHR) systems, SCADA-based infrastructure, and segmented IT, OT, and DMZ networks. It supports controlled cyberattack execution, software-patch evaluation, and training of RL-based defense agents. The testbed is further extended to a digital twin that models the real-time state of the environment using log and network statistics and enables bidirectional interaction through command execution and container lifecycle orchestration. Modbus/TCP and FHIR/HL7 support realistic communication across healthcare and industrial components. Experimental evaluation shows low computation overhead, with average normalized CPU utilization below 0.4 % per container and most lightweight services operating below 0.01%. OpenPLC Modbus TCP operations achieve a median round-trip latency of 0.901 ms. The testbed also captures a multi-stage SSH-based attack propagating from the DMZ to the IT and PLC networks. The framework provides a foundation for extending the emulated environment toward a hardware-enabled hospital digital twin.

0.31

Towards End-to-End Privacy-Preserving AI for Real-Time ECG Monitoring

cs.CR ·2026-10-18 ·Beyazit Bestami Yuksel
published similarity 0.52
Abstract · 9 pages, 4 figures, 2 tables. Accepted to MICCAI 2026 Doctoral Symposium (Springer LNCS)

Healthcare artificial intelligence is shifting from centralized archives toward distributed pipelines that combine wearables, edge processing, cloud analytics, and multi-institutional learning. In this regime, electrocardiogram (ECG) streams cross multiple trust boundaries, so privacy cannot be reduced to a single transmission control. Existing privacy-enhancing technologies typically secure isolated stages and leave gaps between acquisition, analysis, and institutional collaboration. This doctoral research develops a unified lifecycle framework for end-to-end privacy-preserving ECG AI. Rather than introducing another privacy mechanism, it orchestrates complementary privacy-enhancing technologies across the clinical ECG lifecycle, allocating each mechanism to the trust boundary where its security, computational, and operational properties are most appropriate. Three interoperable modules instantiate the framework: AES with CKKS-based homomorphic statistics for secure monitoring; adaptive chaotic protection for low-latency edge transmission; and federated learning with homomorphic aggregation under heterogeneous partitions. Across prototype monitoring, signal-security analysis, and simulated collaboration, the programme shows that privacy layers can be composed without collapsing diagnostic utility, while exposing overhead and fidelity limits that constrain clinical translation.

0.26