CS Paper Radar

A comparison between ceiling-mounted FMCW, IR-UWB and Wi-Fi radar for in-bedroom human activity monitoring and sleep interruption detection

Anton Lambrecht, Reda El Hail, Xianjun Jiao, Pieter Crombez, Dominique Schreurs, Peter Karsmakers, Adnan Shahid, Eli De Poorter

cs.LG ·submitted 2026-08-20 17:58 UTC · v1

Abstract

Despite their growing importance for contact-free radio frequency (RF) based healthcare monitoring, different radio technologies such as frequency-modulated continuous wave (FMCW) radar, impulse radio ultra-wideband (IR-UWB), and Wi-Fi sensing are rarely compared under identical deployment conditions, as existing studies typically differ in hardware, datasets, and evaluation methodologies. In addition, the performance of ceiling-mounted radars, despite their practical deployment and cost advantages in healthcare environments, remain underexplored. Therefore, this paper presents a controlled comparison and analysis of ceiling-mounted FMCW, IR-UWB, and Wi-Fi sensing using synchronized recordings from 20 participants across six room layouts. All technologies are evaluated with the same convolutional neural network (CNN) on both a fine-grained 10-class human activity recognition (HAR) task and a coarse 4-class sleep monitoring task. IR-UWB achieves the highest cross-subject activity recognition performance (89.0% macro F1), while FMCW generalizes best to unseen room layouts (83.8% macro F1). For sleep monitoring, all technologies exceed 92% macro F1 in unseen environments. The results reveal a fundamental trade-off between recognition performance and environmental robustness, which can be explained through differences in range resolution, antenna diversity, Doppler resolution, and spatial information retention. These findings provide practical guidelines for the design of healthcare-oriented RF sensing systems.

Comment
This paper has been submitted to IEEE Access Journal and is currently undergoing review

Closest papers

Nearest neighbours by meaning across the whole index.

Human Activity Recognition using Ceiling-Mounted Multi-Radar Sensors

eess.SP ·2026-10-29 ·Ananya Prabhu, Aditi Site, Tarmo Lipping
similarity 0.63
Abstract

Continuous activity monitoring in assisted living should work without cameras or wearable devices. Radar meets this requirement, but most radar studies use a single sensor and activities recorded in isolation, and few deliver results in real time. We present an indoor monitoring system in which point clouds from three ceiling-mounted radar sensors are fused using density-based clustering, movement and posture features are derived for activity classification, and results are shown on a real-time dashboard. In a preliminary study with eight participants performing everyday activities as one continuous scenario, a random forest reached 74% frame-level accuracy with a random 80/20 split and 68% with leave-one-participant-out evaluation. Without position features, accuracy fell to 46% and 44%, indicating partial dependence on room layout, while window-level features without position reached 67% and 65%.

0.25

Robust Continuous Human Activity Recognition Using Deep Learning and Distributed Radar Sensors

eess.SP ·2026-09-09 ·Sohani Munteha Hiam, Mohammad Soleymani
similarity 0.63
Abstract

Continuous human activity recognition (HAR) with distributed radar sensor networks is challenging because Doppler signatures depend strongly on aspect angle, the informativeness of individual radar views varies with motion direction, and activity transitions in uninterrupted sequences are often ambiguous. This paper proposes a ConvNeXt-MHSA-BiGRU framework for frame-wise continuous HAR from Doppler-time spectrograms acquired by five spatially distributed radar nodes. A shared ConvNeXt-inspired encoder extracts time-frequency representations from each radar stream, while radar-wise multi-head self attention (MHSA) models inter-node dependencies and adaptively fuses complementary views. RadarDropout and SpecAugment-style time-frequency masking regularize the network against unreliable radar views and local spectrogram perturbations, whereas stacked bidirectional gated recurrent units (BiGRUs) exploit temporal context for frame-wise classification across activity transitions. The framework is evaluated on nine activities performed by 14 participants using leave-one-person-out (L1PO) subject-independent testing with fivefold cross-validation. It achieves a mean L1PO test accuracy of 87.56% across the 14 held-out subjects and improves recognition performance over the published CNN-RNN baseline. The results demonstrate that combining modern spectrogram encoding, adaptive radar view fusion, and bidirectional temporal modeling provides an effective framework for continuous and distributed radar-based HAR.

0.24

Human Activity Recognition via Ultra-Wideband Data: A Framework for Dimensionality Reduction, Pattern Discovery, and Predictive Modeling

cs.LG ·2026-09-25 ·Nahid Sahel Gozin, Reza Sedaghat, Prathap Siddavaatam
similarity 0.61
Abstract · 14 pages, 9 figures. Manuscript prepared for submission to an IEEE journal in machine learning

Recent advances in sensor technology have enabled more effective human activity recognition (HAR), particularly in real-time systems with limited computational resources. However, Ultra-Wideband (UWB) radar data remain challenging due to high dimensionality, noise, complexity, and nonlinear characteristics. This research proposes a framework to efficiently reduce data size, uncover significant patterns, and classify six activity types (Standff, Liedown, Noactivity, Sit, Stand, and Walk) from UWB signals with high accuracy. Two novel dimensionality reduction techniques are introduced in this paper. The first, Clustered Polynomial Expansion with Incremental PCA (CPE-IPCA), combines clustering and polynomial feature expansion with Incremental PCA, preserving 100% of the variance in only 50 components. The second, Post-PCA Standardization Approach (PPSA), standardizes data after PCA and retains 99.1% of the variance in 80 components, achieving superior compression and computational efficiency compared to conventional nonlinear methods. Frequent patterns are identified using Apriori and FP-Growth, which are then classified with Random Forest and a Vector Space Model (VSM). The framework achieves 100% accuracy with Random Forest on CPE-IPCA and 99% on PPSA, while VSM attains 100% precision, recall, and F1 on PPSA and near-perfect performance on CPE-IPCA (precision 1.00, recall 0.98-1.00, F1 0.99-1.00), demonstrating a fast, interpretable, and robust HAR system suitable for healthcare, assisted living, and smart environments.

0.26

On-device Detection of Wearer-induced NLOS on Chest-worn UWB Tags: Machine Learning, Link Indicators, or Both?

cs.LG ·2026-10-30 ·Markus Gallacher, Vu Anh Minh Le, Matteo Trobinger, Davide Vecchia, Carlo Alberto Boano +1 more
similarity 0.59
Abstract · Submitted to ACM Transactions on Sensor Networks

Ultra-wideband (UWB) enables high-accuracy distance estimation (ranging), but performance degrades in non-line-of-sight (NLOS) conditions. When UWB tags are worn, the human body inevitably causes a wearer-induced NLOS (WNLOS), yielding significant errors; still, despite its relevance, WNLOS remains understudied. Moreover, WNLOS detection typically must occur on-device at the tag, requiring classification accuracy to be balanced against tight runtime and energy constraints often hard to meet with machine learning (ML) -- the dominating NLOS classification approach. Meanwhile, UWB radio link indicators (LI) offer a faster and lightweight alternative that has rarely been explored. We study existing on-device ML and LI classifiers when applied to WNLOS, and propose novel hybrid ones exploiting their complementarity. We focus on chest-worn tags and analyze 21 classifiers on a dataset of 1.5 million samples across channels, PHY settings, environments, subjects, and orientations. Results show that while all of them achieve good classification accuracy, relative performance, including ranging errors due to misclassification, depends heavily on channel and PHY configuration. Runtime and energy efficiency also vary dramatically; some techniques offer marginal accuracy gains while consuming up to 39.6x more energy. Therefore, we also introduce a recommender tool to identify optimal classifiers under user-defined constraints, publicly released with our dataset.

0.26

A Universal Raw-IQ Radar Encoder for Cross-Sensor Human Sensing

cs.CV cs.LG ·2026-11-03 ·Jonas Leo Mueller, Dario Zanca, Sebastian Hoefler, Jan Petermann, Thomas Altstidl +3 more
publishedbenchmarkpositioncode/data similarity 0.58
Abstract · Accepted at the 2027 IEEE/CVF Winter Conference on Applications of Computer Vision (WACV)

Radar-based human sensing typically relies on end-to-end task-specific models trained on hand-chosen signal projections, which generalize poorly across unseen users, tasks, and hardware. We argue that the dominant signal processing choice, the micro-Doppler spectrogram, is a poor starting point for transfer because it keeps the Doppler axis, which carrier frequency rescales, and discards the angular axis, which carrier frequency leaves unchanged. We instead pretrain a convolutional beta-VAE without labels on clutter-removed raw radar measurements from four platforms spanning 60 and 77 GHz and 4 to 12 virtual antennas, aligned by a unified spectral interpolation grid. For every downstream benchmark the encoder stays frozen, and only a small supervised temporal classifier is trained on its embeddings. We compare against supervised models trained end to end on each benchmark and a pretrained radar foundation model across ten settings covering activity, gesture, sign-language, and gait recognition. When the test users and the radar are seen during training, our encoder is best on all five benchmarks. For users never seen in training, it leads on three of four benchmarks, by 4.8 to 23.2 points. On subject-disjoint gait recognition, it is best for each of the four held-out subjects and 8.3 points above the strongest baseline on average, even though its pretraining excluded every recording of this radar. Excluding the test radar from pretraining costs at most 5.3 points on any benchmark. Code is available at https://github.com/jonasmueler/UniversalRadarEncoder_WACV.

0.50

Floorplan-Context-Aware Cross-Environment Human Activity Recognition from mmWave Radar Point Clouds

cs.CV eess.SP ·2026-11-14 ·Zixiong Han, Xilai Wang, Chenzhe Zhao, Amr Mourad, Miodrag Bolic
similarity 0.58
Abstract · Submitted to ICASSP 2027

Human activity recognition (HAR) models based on mmWave radar point clouds and trained in controlled open spaces often experience performance degradation when deployed in furnished rooms. We propose a Floorplan-Context-Aware (FCA) HAR enhancement method that augments the input with subject-furniture relative position information to improve cross-environment performance. Because existing mmWave point-cloud datasets lack registered floorplans, we introduce a pseudo-landmark augmentation strategy for training the FCA model. In cross-environment evaluation on the mm-ADL-Home dataset, FCA achieves 77.70% accuracy and 65.49% macro-F1, improving upon the point-cloud-only direct-transfer baseline by 10.73 and 10.05 percentage points, respectively, and exceeding the strongest evaluated adaptation baseline by 7.37 and 6.27 percentage points. At deployment, FCA requires only a one-time registration of furniture landmarks, with no target-domain activity annotations or model weight updates.

0.21

Foundation models for movement data: Are they ready for prime-time?

eess.SP cs.LG ·2026-08-13 ·Alexander Bräuer, Benjamin Cauchi, Nils Strodthoff
code/data similarity 0.58
Abstract · 14 pages, 6 figures, 8 tables, code is available at https://github.com/AI4HealthUOL/movement-fm-benchmarking

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

0.30

Towards Field-Deployable Wearable IMU Systems for Occupational Activity Recognition

cs.LG ·2026-10-22 ·Ihsan Ul Haq, James Brusey, Farnad Nasirzadeh, Chandan Karmakar
publishedbenchmark similarity 0.56
Abstract · Accepted at IEEE BSN 2026

Wearable inertial measurement unit (IMU) systems for construction worker human activity recognition (HAR) routinely report aggregate accuracies above 95 %, rarely under genuine subject-independent (leave-one-subject-out (LOSO)) evaluation, masking the per-individual variance that determines real-world deployment performance. Using the VTT-ConIoT benchmark, we conduct, to our knowledge, the first systematic configuration sensitivity analysis of this dataset: six classifiers across five sensor placements and three window sizes under a single LOSO protocol, a personalised-calibration pilot, and a validated comparison of tabular GAN-based and standard time-series augmentation. Per-subject LOSO accuracy for the main multi-sensor, 16-class configuration ranges from 61.9 % to 88.7 % (mean 77.5 %), a 27 pp spread, though all data are laboratory-collected. Multi-sensor fusion and longer windows both improve accuracy; standard augmentation gives small, consistent gains, while Conditional Tabular GAN (CTGAN) augmentation actively harms accuracy with a demonstrated distributional-fidelity mechanism; and personalised calibration recovers 16.8 pp for the weakest participants from just 30 % of their own data. These findings provide evidence-grounded configuration guidance for scaling occupational body sensor networks towards field deployment

0.26