CS Paper Radar

An Evidence-Guided Framework for Tissue-Barrier Impedance Review: Deletion and Resistance Sensitivity

Leo Yang, Yingtong Zhou

eess.SP ·submitted 2026-10-23 13:06 UTC · v1

Abstract

Reviewing tissue-barrier impedance requires connecting spectral anomalies with resistance estimates and experimental context. We present an evidence-guided framework that coordinates numerical checks and traceable actions for human review. In-house simulations assess the effect of removing flagged frequencies, public datasets test model adaptation, and local measurements demonstrate the review workflow. Removing flagged frequencies reduced resistance error under quadratic objectives, whereas robust fitting showed little average benefit from deletion and a mean error increase for endpoint-pair perturbations. High errors clustered around a few fitted circuit parameter sets, highlighting the value of examining parameter identifiability. Under the tested noise and perturbation conditions, these findings support robust full-spectrum estimation, flag-guided inspection, and matched sensitivity checks.

Comment
5 pages, 3 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Single-visit screening for intracochlear tissue growth validated against multi-visit electrical measurement changes

eess.SP ·2026-11-02 ·Minh Q. Vu, Erin L. Bratu, Jared A. Rybarczyk, Jack H. Noble
similarity 0.54
Abstract

Purpose: Tissue growth (TG) around cochlear implant electrodes raises impedance but is not reliably visible on CT scans. Routinely recorded stimulus current-induced non-stimulating electrode voltages (SCINSEVs) carry this information, but a single recording has no patient-specific reference. We present an algorithm for detecting signs of significant TG from a single SCINSEV measurement. Methods: TG is assumed to concentrate basally near the electrode insertion site, leaving the apical region mostly unaffected. A patient-specific forward model built from CT is fitted to the apical measurements and predicts the basal ones. The misfit score, T, measures each basal contact's signed relative misfit against the apical misfit, accounting for apical fit quality and measurement noise. An ear is flagged when two adjacent basal contacts cross a predetermined threshold. We compare T with T-delta, a model-free reference, tracking basal relative to apical SCINSEV change since the intra-operative recording, persisting over the last two visits. Results: T had a false-positive rate of 3% on growth-free ears. It agreed with T-delta in 81% of 68 ears (sensitivity 71%; specificity 86%; p = 6e-6). Over 200 patient-level two-fold splits, median held-out agreement was 78% at a false-positive rate of 5.1%. Conclusion: An apically fitted patient-specific model predicts basal SCINSEVs well enough to flag signs of significant TG at a single visit, without an intra-operative baseline. Detections largely agree with persistent multi-visit basal-versus-apical change, a surrogate ground truth for significant TG.

0.43

An Arduino Giga-Based Multi-Frequency Electrical Impedance Tomography System for Electrolyte Media: Hardware Design, Statistical Voltage Analysis, and System Performance Evaluation

eess.SP ·2026-10-11 ·Zahra Karimi, Natalie Verdugo, Joseph Schwab, Hamid Ghaednia
unusual similarity 0.53
Abstract

Multi-frequency electrical impedance tomography (EIT) often requires specialized hardware. This challenge is especially pronounced in biomedical applications. We developed a 16-electrode EIT system using an Arduino GIGA R1 WiFi for generation and acquisition, with a discrete current source, three analog multiplexers, and basic signal conditioning. Dual cores separate waveform timing from switching and acquisition. A 3D-printed tank with silver-wire electrodes was tested at 11 frequencies (1-180 kHz). Across the 10-180 kHz analysis band, median repeat-frame signal-to-noise ratio was 48 dB, acquisition rate was ~0.18 frames/s per frequency (~60 s per sweep), and cross-session baseline drift was ~6%. KCl phantoms contained an insulating ABS cylinder or KCl-filled dialysis bags (0.001-1.0 M) spanning positive and negative conductivity contrasts. Boundary voltages were analyzed without reconstruction to estimate inclusion position, contrast polarity, and relative magnitude. Leave-one-session-out matching located ABS inclusions in 29/30 runs at 160 kHz (87-97% across the band; chance 33%). For dialysis bags, polarity was correctly identified in all 36 nonzero-contrast runs. Signed voltage projections correlated with the cylindrical contrast factor (R^2=0.68 across runs; R^2=0.89 for the aggregate fit). Concentration was ordered (Spearman rho=0.85), despite saturation above ~10-fold contrast. Bag position accuracy ranged from 6/6 at the highest contrasts to 2/6 at matched conductivity. The matched-conductivity bag produced a ~1.7% RMS perturbation against 0.4-0.6% repeat-frame variability. These results demonstrate that microcontroller-based multi-frequency EIT can support selected detection and identification tasks through direct boundary-voltage analysis, supporting future studies of muscle electrochemistry.

0.25

Robust Readout of Cross-Point Resistive Arrays via Time-Domain Optimization

cs.RO ·2026-11-06 ·Taro Tako, Hiroshi Kaminaga, Taisuke Kobayashi
published similarity 0.50
Abstract · 4 pages, 1 figure, IEEE Sensors 2026 accepted

Cross-point resistive arrays are attractive for high-density tactile sensing because they reduce wiring complexity. However, conventional frequency-based readout methods can become inaccurate in robotic sensing environments, where long interconnects and measurement and environmental noise degrade the observed signals. We propose a time-domain optimization method for robust readout of cross-point resistive arrays. The method determines resistance values by fitting a time-domain observation model to the measured waveform over the interval, rather than relying solely on spectral amplitudes. By exploiting the full waveform, the proposed method improves robustness under noisy observation conditions. In simulations of a 16 x 16 array, the proposed method reduced the mean readout error by 20% compared with the baseline method. Furthermore, validation over 1,000 trials showed that the proposed method achieves more robust estimation than the conventional method, reducing the mean error and standard deviation by 24.6% and 77.6%, respectively. The improvement was also confirmed in cross-point array simulations with resistance distributions emulating tactile sensor responses.

0.39

Short-Range Microwave Interprobe Coupling in a Brain-Mimicking Phantom and Ex-Vivo Brain

eess.SP ·2026-10-12 ·Pouya Faeghi, Xiaoting Jia, Jeffrey S. Walling
similarity 0.50
Abstract · 8 pages, 10 figures, 3 tables

Objectives: Short-range wireless links (microwave range) between closely spaced devices in brain tissue are relevant to neural interfaces and intracranial sensing, yet the change in coupling between two such devices caused by a finite volume of brain-like tissue has rarely been measured directly. Technology or Method: This work characterizes a printed, microstrip-fed, parasitic-strip-loaded tapered-slot coupling probe in which only a partially inserted 12-mm wire enters the medium, while the printed structure remains outside. Results: Two fabricated probes showed a measured free-space -10-dB reflection band of 5.78 to 6.86 GHz and a fractional bandwidth of approximately 17.1%, consistent with full-wave simulation. In a controlled two-probe experiment, a homogeneous agar-gelatin-saline brain-mimicking phantom was introduced and removed while the probe arrangement and measurement conditions were retained. Introducing the phantom increased the measured transmission coefficient near 6.3 GHz by approximately 16 dB, and this differential was reproduced across repeated trials. More than five measurements in ex vivo goat brain followed the phantom transmission response within approximately 1.5 dB across the 5.78-6.86-GHz band. Time-domain analysis of the phantom-present link gave a system root-mean-square delay spread of approximately 210 ps. Full-wave dosimetry predicted a peak 1-g-averaged specific absorption rate of 1.05 W/kg for approximately 0.49 W accepted power. Conclusions and Clinical or Biological Impact: These results provide an experimentally validated reference for short-range probe coupling in brain-like media and support phantom-based bench evaluation of minimally invasive intracranial probes before in vivo studies.

0.23

Data Archive for 2D and 3D Electrical Impedance Tomography with moderate conductivity contrast phantoms

eess.IV cs.LG ·2026-11-12 ·S. J. Hamilton, A. Hauptmann, A. Hänninen, V. Kolehmainen, J. Niskanen +2 more
code/data similarity 0.49
Abstract · 11 pages, 6 figures. Data available at https://doi.org/10.5281/zenodo.24120439

This document describes open Electrical Impedance Tomography (EIT) measurement data that were collected from biomedical imaging inspired phantoms with moderate conductivity contrasts. The data were collected with the KIT4 and KIT5 EIT measurement devices at the University of Eastern Finland, and are intended for EIT image reconstruction algorithm development and testing. The data from thoracic imaging inspired cylindrical and chest-shaped phantoms are suitable for 2D algorithms, and the data from an intracerebral hemorrhage imaging inspired head-shaped phantom with resistive skull are suitable for 3D algorithms. In addition to the measurement data, computational meshes and example reconstruction codes are provided and sample reconstructions included.

0.34

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

eess.SP physics.med-ph ·2026-09-16 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
publishedunusual similarity 0.48
Abstract · 7 pages, 2 figures, submitted to JASA Express Letters

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).

0.41

EITWatch: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition

cs.HC ·2026-08-29 ·Xuanyou Liu, Novel Alam, Karan Ahuja
top venuecode/data similarity 0.47
Abstract · 7 pages, 6 figures, 2 tables. Accepted to UIST '26. Code: https://github.com/XuanyouLiu/EITWatch_Hardware

Wrist Electrical Impedance Tomography (EIT) senses hand gestures from muscle- and tendon-driven impedance changes, but prior wrist-EIT systems require electrode coverage beyond the watch-back contact patch and separate analog front ends. We present EITWatch, the first wrist-EIT system built around smartwatch case-back geometry, asking whether this contact patch alone can support gesture recognition: eight planar electrodes in a 31 mm ring acquire 35 impedance measurements at 48 Hz. Because a planar array cannot encircle the wrist, EITWatch uses multi-depth scanning to sample multiple source-sink distances and current paths; it beat matched adjacent injection by 15.1/10.4 percentage points (macro/micro) across all 12 participants. In a prompted study, within-session leave-one-round-out accuracy reached 91.4%/92.5% (window/trial) for six macro-gestures, and 90.1%/91.5% (window/segment) for five micro-gestures plus relax; window-level cross-session and leave-one-user-out transfer reached 73.2%/70.4% and 63.1%/55.3% (macro/micro).

0.58

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.47
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26