CS Paper Radar

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

Xiaoyang Li, Zeyan Tao

cs.CV ·submitted 2026-08-27 09:04 UTC · v2

Abstract

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

Comment
17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary material; clarified evaluation provenance and limitations

Closest papers

Nearest neighbours by meaning across the whole index.

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution

cs.AI cs.LGeess.SPq-bio.QM ·2026-10-13 ·Xiaoliang Wang, Zhuo Chen, Chuanyang Zheng, Jiangwei Lao, Quanbin Wang +7 more
code/data similarity 0.64
Abstract · Project: https://pork-pay.github.io/ECG-RSI/ GitHub: https://github.com/pork-pay/ECG-RSI

Electrocardiogram (ECG) models need supervision that targets evolving weaknesses and remains faithful to waveform evidence. We introduce ECG-RSI, a recursive self-improvement framework combining verified waveform synthesis with feedback-guided intervention search. Signal remeasurement verifies waveform edits; construction errors guide generator repair, while learner errors motivate interventions compared on a separate selection set. Across seven benchmarks, three rounds raise Qwen3.5-35B-A3B's mean question-answering accuracy from 34.57% to 56.04% and mean classification F1 from 24.27 to 34.03. Across the retained trajectory, the preferred supervision shifts from direct reinforcement to confusion-focused contrasts. Continued feedback correction yields diminishing external gains. These results motivate separating error diagnosis from intervention selection and checking whether gains on the feedback set transfer to independent benchmarks.

0.52

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.62
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

cs.LG cs.AIcs.CReess.SP ·2026-11-16 ·Tsai-Min Chen, Jun Seita
similarity 0.62
Abstract · 12 pages, 9 figures, 2 tables. Corresponding author: Tsai-Min Chen

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

0.32

Conditional Validity for Adaptive Modality Acquisition: When the Policy Chooses Its Own Calibration Group

cs.LG ·2026-08-16 ·Melika Baghi
similarity 0.62
Abstract · 23 pages, 4 figures, 14 tables. Includes appendix with full proofs

A multimodal system may begin inference while holding only some of its inputs and may acquire the rest at a cost. With adaptive acquisition, the policy determines which inputs are ultimately observed, so we state risk control conditional on that terminal input pattern. Conditional calibration typically assumes that the grouping map is fixed independently of the calibration sample, a condition that policy-induced grouping does not satisfy. We characterize when pattern-conditional risk control remains valid and give two finite-sample constructions: threshold-free routing with calibration applied at the terminal pattern, and simultaneous validation of complete policy-pattern pairs, which lets calibration data select the deployed policy. A counterexample shows that validity proved for a calibration-independent grouping map need not transfer once the policy makes the terminal group calibration-dependent. We call the resulting method RouteCert. On a clinical electrocardiogram task with a staged, cost-ordered lead protocol, the deployed policy answers 71.2% of held-out patients, with an observed 7.4% disagreement with the cardiologist's diagnosis at 48.8% of the prespecified ordinal cost of acquiring each stage, and all three acquisition stages are validated separately. On masked multimodal benchmarks, validating pointwise at each terminal pattern holds observed worst-pattern selective risk, measured against the full-information reference decision rather than the true label, at 0.034, where a pooled design reaches 0.145 against a 0.10 cap, at a comparable answered fraction (0.350 vs 0.342); under the budget-matched simultaneous comparison, the answered fraction falls to 0.305.

0.10

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

cs.AI ·2026-11-05 ·Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng +2 more
similarity 0.61
Abstract · 20 pages,3 figures

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

0.23

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.61
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

Sensor-Free Shockable Rhythm Classification During CPR Using the Existing ECG Channel of Public-Access Automated External Defibrillators

eess.SP ·2026-11-19 ·Jaechan Lim, David Hicks, Matt Valentine, Ki H. Chon
similarity 0.59
Abstract

Automated external defibrillators (AEDs) are public-access devices intended for use by lay rescuers, yet they must pause chest compressions to analyze the rhythm because compressions corrupt the electrocardiogram (ECG). Removing this pause requires a method that uses the hardware already present in the device, fits within its processor budget, and meets the rhythm-recognition performance required for defibrillator approval. Existing approaches rely either on an auxiliary sensor, which entails a hardware redesign, or on an additional network that reconstructs the ECG before classification. This work classifies the compression-contaminated ECG directly, using only the existing ECG channel of the AED. A cascade of three compact convolutional networks trained with different class ratios verifies each decision with a second network biased toward the proposed outcome; disagreement yields an indeterminate outcome. Evaluated on an independent manufacturer-provided cohort of 464 subjects over 15 train-validation partitions, the cascade satisfies both adjudicable American Heart Association criteria under all six noise conditions at an eight-second window and a signal-to-artifact ratio of 0 dB, with sinus-rhythm specificity of 99.20-99.43% and other non-shockable specificity of 95.48-96.20%, leaving only 1.07-1.48% of segments indeterminate. The criteria are not met at -3 dB. Single networks matched in parameter count and inference cost do not reproduce this performance. Each decision evaluates two of the three networks and requires 6.68 ms on a single thread of a general-purpose processor, and eight-bit quantization reduces the model to 1.45 MiB without changing any compliance verdict. Thus, rhythm analysis during ongoing CPR can be implemented with the ECG hardware already present in public-access AEDs, without auxiliary sensing hardware, subject to validation on the target device.

0.17

Adaptive Experimentation Can Hide Model Error:Detection Limits and Falsification Budget

cs.AI stat.ME ·2026-11-05 ·Ramnarayan Choudhary
similarity 0.59
Abstract

An experiment can be informative about the parameters of a working model and uninformative about whether that model is wrong. Adaptive design can reinforce this mismatch by repeatedly selecting settings where an incorrect model fits. We bound the power of any valid adequacy test in terms of the experimenter's own sampling distribution, then distinguish information absent from the selected data from information lost by the detector. A computable diagnostic measures unresolved error relative to a declared expansion of the working model. It motivates a training-free rule that reserves part of the design budget for falsification. The empirical record is mixed: the independently specified primary study fails detection eligibility, and a later numerator diagnostic fails its improvement criteria. After the frozen rule fails on fresh continuous-null panels, a disclosed secondary horizon-calibrated revision detects 35.8% of misspecified campaigns versus 31.7% for a class-separation control at T = 240, but has no resolved advantage at T = 480. In a corrected 289-unit measured replay it improves on random design and trails class-discrimination EIG. A conditional futility bound explains why remaining time matters without proving the gate constant or its power. These results support separating parameter learning, model checking and detector performance; they do not establish a universally superior design policy or prospective scientific discovery.

0.30