CS Paper Radar

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

Tsai-Min Chen, Jun Seita

cs.LG cs.AIcs.CReess.SP ·submitted 2026-11-16 11:24 UTC · v1

Abstract

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

Comment
12 pages, 9 figures, 2 tables. Corresponding author: Tsai-Min Chen

Closest papers

Nearest neighbours by meaning across the whole index.

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.62
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.59
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

Beat-Synchronous Tokenization for ECG Transformers

cs.LG eess.SP ·2026-08-31 ·Ahmed Sameh, Nolan Wilson, Max Enderlein, Yogatheesan Varatharajah
published similarity 0.59
Abstract · 6 pages, 1 figure, 3 tables. Accepted at the 2026 IEEE International Workshop on Machine Learning for Signal Processing (MLSP 2026)

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.

0.21

ECG for laboratory values:A comprehensive physiological and technical analysis

cs.LG cs.AI ·2026-10-20 ·Walentin Palanchuk
code/data similarity 0.57
Abstract · 78 pages, 17 figures, source code under https://github.com/WPalanchuk/ECG-for-Labvalues

Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG recordings may contain information beyond cardiac rhythm and provide information related to laboratory values. This thesis investigates NT-proBNP prediction from ECG recordings and patient metadata using a multimodal deep learning framework, while considering the physiological plausibility of ECG-based prediction. It also compares a 1-lead configuration using lead II with the corresponding 12-lead configuration. Additional experiments on glucose, hemoglobin, and potassium are presented in the appendix. Regression, binary classification, and three-class classification experiments were conducted using MIMIC-IV, with the three-class task based on clinically established thresholds. The 12-lead configuration consistently achieved better performance. Regression reached a mean absolute error of 534.98 pg/mL for 1-lead and 514.27 pg/mL for 12-lead. Binary classification achieved AUROCs of 0.849 and 0.876, respectively, while three-class classification achieved macro-averaged AUROCs of 0.738 and 0.752. The results indicate that precise NT-proBNP regression remains challenging, whereas broader concentration ranges can be classified more effectively. The findings are consistent with the physiological hypothesis that ECG characteristics and NT-proBNP concentrations reflect shared cardiovascular processes. ECG-based NT-proBNP prediction may therefore provide complementary information, particularly for classifying broader concentration ranges. However, laboratory measurements remain necessary, and validation on independent datasets is required.

0.37

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.57
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13

Target leakage, not model class, explains reported accuracy in survey-based cardiovascular screening: a leakage-tiered audit of glass-box and tabular foundation models

cs.CL ·2026-09-10 ·Raad Bin Tareaf, Murad Al-Rajab, Samia Loucif, Samer Ellaham, Cedric Schmitz
hot direction similarity 0.56
Abstract

Cardiovascular screening models trained on national health surveys routinely report areas under the receiver operating characteristic curve (AUROC) near 0.89. We asked whether that accuracy reflects learning or target leakage, whether tabular foundation models change the answer, and whether the properties deployment requires survive joint examination. We benchmarked ten classifiers spanning linear, tree-ensemble, neural, glass-box, and tabular foundation classes for prevalent myocardial infarction in 442,067 respondents of the 2022 Behavioral Risk Factor Surveillance System across five feature tiers of decreasing leakage risk. Each was audited for discrimination, calibration, fairness at an explicit screening threshold, conformal coverage, explanation faithfulness, and inference cost, then applied -- models and thresholds frozen -- to 430,755 respondents of 2023. Removing two post-diagnostic features cost every model 0.049-0.051 AUROC, collapsing the field into a 0.0045-wide band. The glass-box explainable boosting machine was non-inferior to every alternative within a pre-specified 0.005 margin while scoring the cohort roughly 104 times faster than the strongest foundation model. One threshold detected 75.4% of women's infarctions against 89.0% of men's; editing the model's shape functions reduced the gap to 0.010. Marginal conformal prediction gave 0.86 coverage to men and 0.82 to adults over 60; Mondrian calibration repaired every stratum. Frozen models transported within 0.002 AUROC. Reported headroom in this literature is a property of the feature set, not the learner. Transparency cost nothing measurable and made fairness repair and uncertainty conditioning directly auditable. Evaluation practice, not model capacity, is the binding constraint.

0.37

Deviation-Aware Pretraining for Cardiovascular Disease Detection from Electrocardiograms

cs.LG ·2026-11-10 ·Siyuan Yan, Haibo Zheng, Feng Lu, Wei Li
similarity 0.56
Abstract

Electrocardiogram (ECG) signals are critical for cardiovascular disease (CVD) detection. Most current deep learning models rely on supervised, task-specific training, which limits their ability to generalize across diseases, patient populations, and acquisition settings. This paper presents a self-supervised ECG feature extraction framework that learns from nearly one million unlabeled 12-lead ECG recordings. The framework includes two modules: Deviation Localization Embedding (DLE), which detects waveform-level deviations from normal patterns, and Association Reconstruction Embedding (ARE), which models cross-lead associations through deviation-guided reconstruction to capture abnormal patterns expressed across multiple leads. These modules enable the framework to capture subtle deviation-related patterns and their cross-lead context. The framework achieves up to 6.5% AUROC and 12.8% F1 improvements over prior methods on multiple public datasets, even without additional fine-tuning the pretrained feature extractor. Embedding visualizations show that the learned features support meaningful disease grouping and anomaly identification. The approach reduces the need for labeled data and can support clinicians in diverse healthcare settings. The framework has potential to improve early detection and monitoring of cardiovascular diseases, contributing to more accessible and equitable heart care.

0.20

BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

cs.LG cs.AI ·2026-11-17 ·Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi
similarity 0.56
Abstract

Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68\,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.

0.36