BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

Ugo Lomoio, Pierangelo Veltri, Pietro Hiram Guzzi

cs.LG cs.AI ·submitted 2026-11-17 10:20 UTC · v1

Abstract

Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68\,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.

Closest papers

Nearest neighbours by meaning across the whole index.

ECG for laboratory values:A comprehensive physiological and technical analysis

cs.LG cs.AI ·2026-10-20 ·Walentin Palanchuk
code/data similarity 0.60
Abstract · 78 pages, 17 figures, source code under https://github.com/WPalanchuk/ECG-for-Labvalues

Laboratory measurements are essential for clinical decision making but typically require invasive blood sampling. Recent research suggests that ECG recordings may contain information beyond cardiac rhythm and provide information related to laboratory values. This thesis investigates NT-proBNP prediction from ECG recordings and patient metadata using a multimodal deep learning framework, while considering the physiological plausibility of ECG-based prediction. It also compares a 1-lead configuration using lead II with the corresponding 12-lead configuration. Additional experiments on glucose, hemoglobin, and potassium are presented in the appendix. Regression, binary classification, and three-class classification experiments were conducted using MIMIC-IV, with the three-class task based on clinically established thresholds. The 12-lead configuration consistently achieved better performance. Regression reached a mean absolute error of 534.98 pg/mL for 1-lead and 514.27 pg/mL for 12-lead. Binary classification achieved AUROCs of 0.849 and 0.876, respectively, while three-class classification achieved macro-averaged AUROCs of 0.738 and 0.752. The results indicate that precise NT-proBNP regression remains challenging, whereas broader concentration ranges can be classified more effectively. The findings are consistent with the physiological hypothesis that ECG characteristics and NT-proBNP concentrations reflect shared cardiovascular processes. ECG-based NT-proBNP prediction may therefore provide complementary information, particularly for classifying broader concentration ranges. However, laboratory measurements remain necessary, and validation on independent datasets is required.

0.37

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.60
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

Compact and Decodable Electrocardiogram Text for Large Language Models

cs.CL ·2026-11-17 ·Elif Dorukbaşı, İlker Türker
code/data similarity 0.56
Abstract · 9 pages, 5 figures, 5 tables. Preprint of a chapter submitted to "Advances in Artificial Intelligence and Data Science: Methods, Systems, an…

When a twelve-lead electrocardiogram is written as text for a large language model, the number of tokens has to be balanced against the information lost through compression. This paper presents a deterministic encoding that writes eight independent leads as amplitude letters and exact time gaps and recovers the remaining four limb leads algebraically. The key points are selected with a cardiac-cycle-dependent tolerance, the amplitudes are parameterized by a 26-letter logarithmic codebook learned from a training set, and a 10-step tolerance schedule keeps all records within a fixed token budget. The encoding was applied to 21,388 records from the public PTB-XL database and evaluated using an exact decode-and-re-encode round trip, waveform reconstruction error, and a paired comparison of convolutional classifiers trained with 5 different seeds on signals from the original and decoded databases. All records were contained in 4,080 tokens (average: 2,866 tokens, 64.3% fewer than a per-sample transcription), and all stored lead strings were exactly reproduced. The average correlation between the decoded and reference signals was 0.982. The macro-averaged area under the receiver operating characteristic curve was 0.9167 for the reference signals and 0.9157 for the decoded signals (paired difference -0.0010; 95% patient-level bootstrap interval, -0.0028 to 0.0007), within the pre-specified non-inferiority margin of -0.010; this is not a confirmatory result, because the test fold had been used during encoder development. The diagnostic content of a compact text can therefore be preserved, while the language model's ability to read the text is yet another matter.

0.43

Same path, different walk: a mechanistic comparison of looped and stacked transformer encoders on 12-lead ECG

cs.LG math.DS ·2026-09-14 ·Pawel Olszowiec, Michal Byra, Grzegorz Gruszczynski, Grzegorz Stefanski, Alberto Presta
similarity 0.56
Abstract · 5 pages, 7 figures

Recurrent Transformers reusing their weights rather than stacking $L$ distinct layers are becoming widely adopted due to their parameter efficiency [1,2,3]. However, the exact representational and dynamical differences between looped and stacked architectures remain uncharacterized. This paper presents a controlled study on the example of bViT model [1] applying one weight-tied block $L$ times. We train two models: bViT and standard ViT [4] on 12-lead electrocardiogram (ECG) classification tasks from the PTB-XL dataset under identical training protocols. Despite an $8.9\times$ parameter reduction, bViT achieves accuracy parity with ViT. Geometric similarity metrics demonstrate that both architectures construct comparable latent representations in an equivalent canonical order. Crucially, their dynamics differ: bViT exhibits smaller step sizes and inter-patient sensitivity, as well as near-neutral behavior away from the data manifold, whereas ViT exhibits collapsing dimensionality of representations and out-of-distribution feature expansion.

0.54

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

cs.LG cs.AIcs.CReess.SP ·2026-11-16 ·Tsai-Min Chen, Jun Seita
similarity 0.56
Abstract · 12 pages, 9 figures, 2 tables. Corresponding author: Tsai-Min Chen

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

0.32

Beat-Synchronous Tokenization for ECG Transformers

cs.LG eess.SP ·2026-08-31 ·Ahmed Sameh, Nolan Wilson, Max Enderlein, Yogatheesan Varatharajah
published similarity 0.55
Abstract · 6 pages, 1 figure, 3 tables. Accepted at the 2026 IEEE International Workshop on Machine Learning for Signal Processing (MLSP 2026)

Transformer-based electrocardiogram (ECG) models commonly tokenize waveforms into fixed temporal patches. Though convenient, fixed patching can split heartbeat structures across token boundaries. We study beat-synchronous tokenization as a physiologically grounded alternative, comparing fixed patches with three beat-aligned strategies: resampled beats, adaptive pooled beats, and resampled beats augmented with R--R interval information. Experiments span two settings: 10-second 12-lead diagnostic classification on PTB-XL after MIMIC-IV-ECG masked pretraining, and 60-second single-lead rhythm classification on Icentia11k after patient-level contrastive pretraining. On PTB-XL, resampled beat tokens achieve the highest mean macro Area Under the ROC Curve (AUROC; 0.8945) and nearly match the best fixed-patch macro Area Under the Precision-Recall Curve (AUPRC; 0.7414), reducing average sequence length from 100 to 11.2 tokens. On Icentia11k, beat-synchronous tokenizers obtain comparable AUPRC to fixed patching with better stability across runs. These results suggest morphology-preserving beat tokenization is a compact, competitive alternative to fixed temporal patching.

0.21

RAG-TRACE: Tracing Measurement Evidence and Diagnostic Completeness in AI-Generated ECG Reports

cs.CL ·2026-11-01 ·Elyas Irankhah, Shahed Salehzehi, Parisa Hosseini
code/data similarity 0.52
Abstract · Code and study materials available at https://github.com/Elyasirankhah/RAG-TRACE

Purpose: Retrieval-augmented generation (RAG) can introduce electrocardiogram (ECG) criteria that lack patient-specific measurement support. This study evaluates the reliability of retrieved diagnostic criteria in AI-generated ECG reports. Methods: We analyzed 1,083 human-validated PTB-XL patient records using a library of 47 criteria cards, including 33 without numeric verification rules. Language models generated structured reports with and without retrieval. Criterion applicability was evaluated using Marquette 12SL measurements, with independent assessment using Uni-G and comparison against expert-validated diagnostic labels. Results: Keyword retrieval introduced untestable or measurement-disconfirmed criteria in 46.8% of GPT-4.1-mini reports. A deterministic verification rule withdrew 647 criterion applications, including 639 without numeric checks, while preserving 268 of 269 applications independently supported by Uni-G. Restricting retrieval to 14 testable criteria reduced the initial unsupported-criterion rate to 13.8%. Under matched instructions and an identical output schema, retrieval increased unsupported-criterion reports from 17.4% to 31.1%, while hypertrophy recall remained unchanged at 62.6%. Conclusion: These findings identify a fundamental limitation of retrieval-based clinical report generation: retrieved criteria do not necessarily provide valid patient-specific evidence. Measurement-based verification can reduce unsupported criterion applications, but diagnostic validity requires independent assessment.

0.41

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.52
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26