CS Paper Radar

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng, Wei Wang, Haomin Li

cs.AI ·submitted 2026-11-05 09:36 UTC · v1

Abstract

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

Comment
20 pages,3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.67
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution

cs.AI cs.LGeess.SPq-bio.QM ·2026-10-13 ·Xiaoliang Wang, Zhuo Chen, Chuanyang Zheng, Jiangwei Lao, Quanbin Wang +7 more
code/data similarity 0.64
Abstract · Project: https://pork-pay.github.io/ECG-RSI/ GitHub: https://github.com/pork-pay/ECG-RSI

Electrocardiogram (ECG) models need supervision that targets evolving weaknesses and remains faithful to waveform evidence. We introduce ECG-RSI, a recursive self-improvement framework combining verified waveform synthesis with feedback-guided intervention search. Signal remeasurement verifies waveform edits; construction errors guide generator repair, while learner errors motivate interventions compared on a separate selection set. Across seven benchmarks, three rounds raise Qwen3.5-35B-A3B's mean question-answering accuracy from 34.57% to 56.04% and mean classification F1 from 24.27 to 34.03. Across the retained trajectory, the preferred supervision shifts from direct reinforcement to confusion-focused contrasts. Continued feedback correction yields diminishing external gains. These results motivate separating error diagnosis from intervention selection and checking whether gains on the feedback set transfer to independent benchmarks.

0.52

Learning from VAE Errors to support ECG-based Differential Diagnosis of Myocardial Scar

cs.LG stat.ML ·2026-09-04 ·Shayan Sharifi, Riccardo Treu, Ilaria Gandin, Federico Garoia, Marco Merlo +1 more
similarity 0.64
Abstract · Accepted at the PharML Workshop, ECML PKDD 2026

Late Gadolinium Enhancement (LGE) on cardiac magnetic resonance is a key marker of myocardial scar, but its limited accessibility motivates routine ECG-based screening. We evaluated whether $β$-variational autoencoder (VAE)-derived ECG representations can discriminate LGE+ from LGE- cardiomyopathic patients in a local cohort of 300 subjects. We compared 32-dimensional features from the foundation ECGx.AI model with those from a shallower $β$-VAE trained on normal PTB-XL ECGs, evaluating downstream classification and Dynamic Time Warping (DTW)-based reconstruction errors. ECGx.AI reached an area under ROC of 0.686 with Random Forest, while the proposed $β$-VAE reached 0.577 with sensitivity of 0.775 with Gradient Boosting. Notably, DTW-reconstruction errors significantly differed between classes in 10 out of 12 leads according to Mann-Whitney U test and help in classification, leading to an area under ROC of 0.643 with Logistic Regression, supporting their potential as markers of scar-related ECG alterations.

0.22

Cardiac MRI-informed electrocardiography enables biologically grounded cardiomyopathy detection

cs.AI q-bio.QM ·2026-11-18 ·Zhengyao Ding, Kewen Wang, Yujian Hu, Ziyu Li, Yiheng Mao +25 more
similarity 0.62
Abstract · 46 pages, 9 figures

Precise myocardial phenotyping at population scale is limited by the cost and accessibility of cardiac magnetic resonance (CMR), whereas electrocardiography (ECG) is widely available but reflects electrical rather than structural and functional information. Here we develop MyoECG, a cross-modal representation learning framework that distils myocardial structural and functional knowledge from CMR into standard 12-lead ECGs, enabling imaging-informed cardiomyopathy detection and subtype classification from ECGs alone. MyoECG was pretrained on 45,241 paired ECG-CMR examinations from UK Biobank and a tertiary cardiovascular centre, then developed and validated across more than 1.8 million ECGs from seven independent datasets. Across internal and external datasets spanning prevalences of 0.2-54.7%, MyoECG outperformed five pretrained ECG foundation models, with AUROCs of 0.800-0.974 for cardiomyopathy detection. In a multi-reader study of six cardiologists, MyoECG assistance improved mean sensitivity by 0.109 (95% CI, 0.041-0.175; P = 0.009) and specificity by 0.056 (95% CI, 0.004-0.108; P = 0.040). In 41,128 UK Biobank participants, the MyoECG score showed genetic correlations with cardiomyopathy (rg = 0.409) and dilated cardiomyopathy (rg = 0.371), genome-wide associations at four loci, including regions mapped to NFIA and KCNQ1, and associations with 69 circulating proteins related to myocardial stress, cell adhesion, vascular biology and metabolism. The cardiomyopathy correlation attenuated to non-significance after adjustment for 27 measured CMR traits (rg = 0.131; P = 0.143), indicating that the score captures CMR-derived information rather than dataset-specific shortcuts. MyoECG offers a scalable route to CMR-informed cardiomyopathy assessment and a strategy for transferring knowledge from resource-intensive imaging to widely deployable physiological signals.

0.15

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.61
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26

Target Recoverability under Selective Labels: A Failure Mode in ECG-Based Acute Coronary Syndrome Prediction

cs.LG cs.AI ·2026-11-08 ·Alexander Schubert, Anton Håkansson, Ziad Obermeyer
top venue similarity 0.61
Abstract · Accepted to the Proceedings of Machine Learning for Health (ML4H) 2026

Medical machine learning models often learn from diagnoses observed only in patients clinicians chose to test. The biases of such selective labels are well known, but less understood is what happens when a diagnosis includes cases the model's inputs cannot detect. Because testing decisions draw on information the model does not see, these cases can appear predictable among tested patients, producing relationships that fail, and can even reverse, among the untested. We formalize this mechanism and show in simulations that it worsens as testing becomes more selective or undetectable cases more common, while models trained only on detectable cases remain informative. We empirically study electrocardiogram (ECG)-based prediction of acute coronary syndrome (ACS), which is confirmed only by invasive testing and whose subtypes differ in how clearly they appear on the ECG. Three ECG foundation models fine-tuned on revascularization, our ACS proxy, performed well among catheterized patients (AUROC 0.740-0.770) but worse than chance for 30-day major adverse cardiovascular events among untested patients (AUROC 0.381-0.478). Models trained on ECG-visible subtypes retained discrimination (AUROC 0.680-0.709), whereas a model trained on unstable angina, which can occur without ECG changes, was inversely related to risk (AUROC 0.310). Under selective labels, effective learning therefore requires prediction targets that can be inferred from the model's inputs and evaluation in the intended deployment population, which often extends beyond the patients who were tested.

0.31

CardioFusion-AI: Robust ECG--PPG Fusion for Multimodal Physiological Monitoring Under Signal Degradation

eess.SP cs.LGq-bio.QM ·2026-08-26 ·Navaneetha Krishnan Kamalakannan, Janakiraman Kamalakannan
code/data similarity 0.61
Abstract · 7 pages, 4 figures. Under review at IEEE Journal of Biomedical and Health Informatics. Code: https://github.com/ka-cyber/CardioFusion-AI

Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.

0.60

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.60
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55