CS Paper Radar

ECG-RSI: Recursive Self-Improvement through Targeted Electrocardiogram Waveform Evolution

Xiaoliang Wang, Zhuo Chen, Chuanyang Zheng, Jiangwei Lao, Quanbin Wang, Honglin Lin, Jiajia Liu, Zhihong Lu, Hao Jin, Jian Wang, Jinjie Gu, Lijun Wu

cs.AI cs.LGeess.SPq-bio.QM ·submitted 2026-10-13 04:50 UTC · v2
code/data

Abstract

Electrocardiogram (ECG) models need supervision that targets evolving weaknesses and remains faithful to waveform evidence. We introduce ECG-RSI, a recursive self-improvement framework combining verified waveform synthesis with feedback-guided intervention search. Signal remeasurement verifies waveform edits; construction errors guide generator repair, while learner errors motivate interventions compared on a separate selection set. Across seven benchmarks, three rounds raise Qwen3.5-35B-A3B's mean question-answering accuracy from 34.57% to 56.04% and mean classification F1 from 24.27 to 34.03. Across the retained trajectory, the preferred supervision shifts from direct reinforcement to confusion-focused contrasts. Continued feedback correction yields diminishing external gains. These results motivate separating error diagnosis from intervention selection and checking whether gains on the feedback set transfer to independent benchmarks.

Comment
Project: https://pork-pay.github.io/ECG-RSI/ GitHub: https://github.com/pork-pay/ECG-RSI

Closest papers

Nearest neighbours by meaning across the whole index.

Pediatric ECG foundation model via adult-to-pediatric fine-tuning: downstream tasks and clinical evaluation

cs.AI ·2026-11-05 ·Yu Cao, Haiyan Xu, Xiaohan Li, Jian Yang, Yuqing Feng +2 more
similarity 0.64
Abstract · 20 pages,3 figures

Pediatric electrocardiogram (ECG) interpretation is complicated by age-dependent electrophysiological changes that limit direct transfer of adult AI models. We asked whether an adult ECG foundation model could be adapted to pediatric ECGs. Using 339,563 12-lead ECGs from 238,189 children, we compared direct application, pediatric fine-tuning, and training from scratch under an identical architecture. Direct transfer was poor (mean AUC 0.8256). Fine-tuning reached 0.9695, above de novo training (0.9661), and attained 0.9079 using only 1% of training data. On 10,999 external ECGs, fine-tuning achieved a mean AUC of 0.9385 across 30 labels. It generalized to age regression (MAE 1.12 years) and congenital heart disease classification (AUC 0.9562). Across 17 clinicians and 100 cases, diagnostic accuracy rose from 56.8% to 65.4% (p < 0.001) and did not decline when AI erred. Adult ECG foundation models require pediatric adaptation; fine-tuning offers a data-efficient route to scalable pediatric ECG AI.

0.23

Test-Time Adaptation for ECG Classification via SQI-Gated Self-Training and Beat-Rhythm Consistency

cs.LG ·2026-08-24 ·Wenhan Jiang, Zhipeng Deng, Jiale Zhou, Haolin Wang, Yafei Ou +1 more
top venue similarity 0.64
Abstract · Accepted at MICCAI 2026

Deep learning models for electrocardiogram (ECG) classification often suffer from significant performance degradation when deployed in unseen domains due to shifts in acquisition devices and patient populations. Test-time adaptation (TTA) offers a practical solution by adapting models using only unlabeled data at inference time. However, existing TTA methods often underperform on ECG tasks, since naive online updates ignore the hierarchical beat-rhythm structure of cardiac cycles and are vulnerable to signal artifacts, which leads to unstable adaptation and model drift. We propose BeatRhythm-TTA, an ECG-tailored TTA framework that explicitly accounts for ECG's noisy observations and structured beat-rhythm semantics under domain shift. First, to handle pervasive ECG artifacts, we introduce a Signal Quality Index (SQI)-gated adaptation scheme that selectively filters out low-quality signals to prevent harmful updates. Second, to leverage ECG's beat-rhythm semantics, we enforce dual-level consistency so the model preserves beat morphology and rhythm dynamics while adapting to shifted acquisition conditions. Extensive experiments on multi-label ECG diagnosis across three adaptation protocols, using PTB-XL as the source domain and CPSC2018/Georgia as two target domains, demonstrate the effectiveness of our method, yielding an average +2.70% relative improvement in Macro-F1 over the best competing method.

0.55

Evaluator-Dependent Patient-Adaptive ECG Lead-Channel Allocation

cs.CV ·2026-08-27 ·Xiaoyang Li, Zeyan Tao
similarity 0.64
Abstract · 17 pages: 5-page main paper and 12-page supplementary material; 6 figures and 16 supplementary tables. Updated figures and supplementary mat…

The diagnostic value of an ECG channel depends on the model that interprets it. We test whether adaptive acquisition retains its advantage over fixed protocols when that model changes. Two policies developed with a logistic evaluator are frozen and assessed with a masked waveform ResNet1D, using exhaustive, metric-matched fixed comparators. On PTB-XL, replacing the evaluator reverses the mean adaptive advantage in negative log-likelihood and Brier score across the tested budgets, while calibration responds less uniformly. The shift persists with common fixed references and broader training-mask exposure. Training a policy against the stronger evaluator partly recovers the lost advantage. These retrospective exploratory results show that acquisition quality cannot be assessed independently of the downstream evaluator and motivate validating adaptive policies with the model intended for diagnosis.

0.26

ECGJev: Question-Conditioned Option Scoring for 12-Lead ECG Interpretation

cs.LG eess.SP ·2026-11-01 ·Zhuoyuan Li, Xidong Wu, Hanyu Cui, Jiansong Gao, Rongrong Fu +2 more
code/datahot direction similarity 0.63
Abstract · 5 pages (4 pages plus ethics statement and references), 2 figures. Submitted to IEEE ISBI 2027. Zhuoyuan Li and Xidong Wu contributed equall…

Clinical interpretation of a 12-lead electrocardiogram (ECG) often requires answering targeted diagnostic questions with clear, quantifiable decisions. We introduce ECGJev, the first ECG framework built on a decision decoder, a pretrained language model trained to return a probability for every listed option. A question-conditioned bridge compresses frozen waveform and spectrogram features into 16 ECG tokens, and a two-stage procedure adapts the bridge and low-rank adapters on the decoder's native option readout using diagnostic labels alone, scoring all options for a question in one forward pass. Evaluated across four ECG benchmarks, ECGJev achieves the highest macro-F1 on CPSC2018 (80.46%), PTB-XL (71.68%) and Chapman (96.86%), and generalizes competitively to the small-sample PTB cohort. Concept probes and perturbation analyses further show that its predictions rely directly on the ECG input, remain stable under option-order and wording variations, and transfer zero-shot to unseen waveform concepts. Our code is available at https://github.com/zhuoyuanli-lab/ECGJev.

0.34

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

cs.CL cs.IR ·2026-08-31 ·Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
benchmarkcode/data similarity 0.63
Abstract

Electrocardiogram (ECG) interpretation requires knowledge of cardiology, electrophysiology, clinical diagnosis, ECG waveforms, signal acquisition, and instrumentation. Existing language-model benchmarks, however, primarily assess broad medical knowledge or interpretation of individual ECG signals and images rather than the broader contextual knowledge required for ECG interpretation. We developed ECGQuest, a literature-grounded resource for evaluating and fine-tuning ECG-specific language models. A GPT-4o-based pipeline generated questions from 23 ECG references and Computing in Cardiology proceedings from 2003-2025. The final dataset contains 10,904 unique True/False questions paired with their negated forms (21,808 Q&A pairs). We evaluated three commercial and 20 open-source language models on a held-out test set in a zero-shot setting. Five open-source models with 7-14B parameters were fine-tuned using Low-Rank Adaptation, with BERT and BiomedBERT included as supervised encoder baselines. Generalization was assessed on ECG-related subsets of MedMCQA and MedQA converted to binary True/False questions using official answer keys. Zero-shot accuracy on ECGQuest ranged from 49.5% to 74.4%, with GPT-5 performing best. General-purpose models outperformed medically specialized models, several models showed strong True/False bias, and encoder baselines performed near chance. Fine-tuning improved all open-source models by 6.5-14.1%. Fine-tuned DeepSeek-R1-Distill-Qwen-14B reached 76.3% accuracy, while a five-model voting ensemble reached 78.5%. On MedMCQA and MedQA, fine-tuning mainly benefited weaker or class-biased models and did not consistently improve strong base models. ECGQuest provides a reproducible benchmark for contextual ECG knowledge and shows that parameter-efficient fine-tuning can make smaller language models competitive with substantially larger commercial models.

0.35

IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for Electrocardiogram

cs.AI ·2026-10-20 ·Huynh Dang Nguyen, Trong-Thang Pham, Anh-Thuan Do, Phuong-Nhi Dinh, Brijesh Patel +2 more
published similarity 0.60
Abstract · Accepted in WACV 2027

Electrocardiography (ECG) is a cornerstone of cardiac diagnosis, yet most machine learning methods for ECG analysis lack interpretability, limiting their clinical adoption. We present IECG, a weakly-supervised ECG foundation model that jointly performs diagnostic classification and abnormality localization without requiring manual abnormal region annotations, overcoming a long-standing bottleneck in interpretable ECG learning. Central to IECG is a weakly-supervised attention strategy that explicitly incorporates clinical priors by deriving abnormality heatmap pseudo-labels from established ECG clinical knowledge. These pseudo-labels guide the model's CLS-token attention through a KL-divergence loss, encouraging it to focus on diagnostically relevant waveform regions. During pretraining, IECG is jointly optimized with clinically guided attention supervision, ECG-text contrastive alignment, and report captioning objectives, enabling it to learn rich multimodal representations while producing localized waveform evidence. By explicitly aggregating features from clinically guided attention regions, IECG grounds its diagnostic predictions in interpretable waveform evidence without sacrificing classification performance. Extensive experiments demonstrate that IECG achieves state-of-the-art abnormal region localization while maintaining strong classification performance, advancing trustworthy foundation models for ECG analysis.

0.31

PACE-ECG: Patient-Aware Contrastive ECG Pretraining; Leveraging Longitudinal Structure for Transferable Representations

cs.AI ·2026-11-09 ·Riccardo Cavarra, Lupo Lovatelli, Shaheim Ogbomo-Harmitt, Jakub Grzelak, Adelaide De Vecchi +2 more
similarity 0.60
Abstract

Foundation models for physiological signals are commonly evaluated on in-domain interpretation tasks, but their ability to transfer to longitudinal clinical prognosis across healthcare systems remains uncertain. We developed PACE-ECG, an ECG pretraining framework that combines contrastive learning across temporally neighbouring recordings from the same patient with clinically guided multitask supervision. We evaluated frozen ECG representations for post-myocardial-infarction all-cause mortality and incident heart failure prediction across MIMIC-IV and two external HEEDB cohorts, comparing the proposed representation with DeepECG-SSL, a state-of-the-art model, and two control baselines. Across both downstream tasks, the proposed model outperformed DeepECG-SSL in-domain (AUROC +1.9% for mortality and +4.0% for heart failure) and on external populations in HEEDB-Boston (+5.6% for mortality +10.3% for heart failure) and HEEDB-Atlanta (+6.9% for mortality +11.0% for heart failure) while using an encoder 41 times smaller and a fraction of the pretraining data. A matched ablation showed that patient-temporal pairing improved external mortality and heart failure AUROC over generic self-supervision by 7.0% and 9.4% on HEEDB-Boston and 8.9% and 9.3% on HEEDB-Atlanta. These findings indicate that pretraining-objective design greatly influences downstream transfer alongside model and data scale, and that in-domain performance alone is insufficient to establish the clinical generalisability of ECG foundation representations.

0.17

Diagnosing as Cardiologists Do: ECG Agents with Doctor-Grounded Priors for Clinical Reasoning Across Diseases and Populations

eess.SP cs.CVcs.LG ·2026-08-10 ·Hongxiang Gao, He-yang Xu, Yuwen Li, Minghui Zhao, Zhipeng Cai +4 more
benchmark similarity 0.60
Abstract

Cardiologists interpret electrocardiograms by localizing waveform components, measuring rhythm and interval patterns, and translating these structured observations into diagnostic evidence. Whether this expert reading process can serve as an effective prior for ECG agents remains unclear. To address this question, we introduce LuminaECG, a clinically structured ECG reasoning framework that reformulates ECG interpretation as measurement-grounded visual reading. ECG signals are rendered on standard electrocardiographic grid paper to preserve the spatial and scale cues used in clinical reading. P-wave, QRS-complex, and T-wave boundaries are explicitly delineated, and color-coded segmentation decomposes the waveform into discrete visual measurement primitives. A general 2B vision-language backbone is then trained with low-rank supervised fine-tuning to associate these primitives with diagnostic reasoning, without architectural modification. Across open, proprietary, and ECG-specialist zero-shot baselines, LuminaECG improves both waveform measurement and diagnostic recovery. It reaches a clinically meaningful reader tier on the CODE-test benchmark, transfers across geographically diverse ECG datasets without retraining, and generates reports whose structure contains an emergent prognostic signal. These findings suggest that effective ECG agents require not only larger models, but supervision that preserves the alignment between measurable waveform evidence and clinical knowledge.

0.04