CS Paper Radar

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila

eess.SP physics.med-ph ·submitted 2026-09-16 21:59 UTC · v1
publishedunusual

Abstract

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).

Comment
7 pages, 2 figures, submitted to JASA Express Letters
Journal ref
JASA Express Lett. 6, 102001 (2026)
DOI
10.1121/10.0046858

Closest papers

Nearest neighbours by meaning across the whole index.

Complementary-Aperture Pulse Sequencing for Fundamental-Band Nonlinearity Parameter Imaging

eess.SP physics.med-ph ·2026-09-19 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
published similarity 0.63
Abstract · 4 pages, 3 figures, accepted to 22nd International Symposium on Medical Information Processing and Analysis (SIPAIM)

The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation because of the slightly nonlinear scaling between excitation voltage set on the ultrasound system and pressure at the probe. We propose a complementary-aperture pulse sequence (CAPS) that recovers the linearly scaled low-pressure signal by coherently summing RF acquisitions from interleaved transmit subapertures whereas a full-aperture transmission provides the high-pressure signal maintaining the same excitation voltage configured in the ultrasound system. In silico phantoms of a homogeneous sample and a reference evaluated four aperture partitions of CAPS and compared them with the DM under relative scaling-factor errors from 0.01% to 10%. Using the DM, errors of 0.1% and 1% produced absolute B/A biases of up to 27.3% and 58.3%, respectively. CAPS yielded mean B/A values of 8.9 for a prescribed value of 9, with biases of less than 1.3% across all partitions, matching an ideally calibrated DM. These results demonstrate that CAPS preserves depletion-based B/A estimation without using the pressure scaling factor as a reconstruction input, supporting experimental and in vivo implementation without pressure-ratio calibration.

0.32

Compression Hurts, Pooling Helps: Information Loss in Rayleigh-Scale Estimation from B-Mode Ultrasound

eess.IV cs.CVstat.AP ·2026-09-17 ·D. Hudson Smith, Ahmer Raza
similarity 0.52
Abstract · 20 pages, 7 figures

Clinical B-mode images are widely available as potential data sources for quantitative ultrasound (QUS) analysis for tissue characterization. However, standard clinical ultrasound devices apply unknown log-compression to RF envelope data before display and storage. Previous work has demonstrated estimation of the underlying RF envelope statistics in the presence of an unknown compression law. Using Fisher information analysis, we show that finite-offset log compression causes severe information loss when estimating the Rayleigh scale $σ$, which controls diffuse speckle. For a single image window, unknown compression raises the minimum achievable variance for unbiased estimation of $σ$ by a compression-independent factor of approximately 34.98. When $M$ equal-sized windows share the same unknown compression settings, the excess variance decays as $1/M$; even in the most favorable regime, reducing the variance inflation factor below 1.1 requires 340 windows. Our analysis treats the contrast parameter $a$ as unknown and the boundary offset $b$ as known; estimating $b$ experimentally shows even larger variance. We validate this theory using synthetic estimation experiments and demonstrate RF-scale recovery on real RF-envelope windows from the OASBUD dataset. Together, these results clarify the limitations of using routine B-mode images for QUS.

0.32

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.52
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published similarity 0.52
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36

Solving the Nonlinear Westervelt Equation in Ultrasound Propagation Using Physics-Informed Neural Networks

cs.LG math.APcs.NE ·2026-11-03 ·Luke Oluwaseye Joel
similarity 0.51
Abstract · 17 pages, 21 figures

Modeling the nonlinear acoustic wave propagation in biological tissues needs accuracy, especially in ultrasound imaging and therapeutic applications. The 1D Westervelt equation, \( p_{xx} - p_{tt} + γ\, p_{ttt} + η\,(p^{2})_{tt}=0, \) could be used to describe a finite-amplitude ultrasound propagation in these tissues. This equation accounts for nonlinearity, \(η\), and attenuation, \(γ\). To solve this equation, we observe that traditional solvers may struggle to do so correctly. This is due to the difficulties arising from the nonlinear nature of the equation. We solve the equation by defining three synthetic cases - linear (\(η=0.001\), \(γ=10^{-6}\)), shock-dominated (\(η=0.02\), \(γ=10^{-6}\)), and dissipation-dominated (\(η=0.01\), \(γ=5\times10^{-4}\)) - and using Physics-Informed Neural Networks (PINNs) to showcase the solution. A sinusoidal activation function is used to capture the oscillatory behavior of the problem. The results of our study, with PDE residual converging to at least \(10^{-6}\), boundary condition loss to \(10^{-5}\), and the PINN loss converging to \(10^{-5}\) for each case at \(30,000\) epochs, show that \(γ\) scales the rate of amplitude decay, while \(η\) governs frequency-dependent phase speeds.

0.27

Dielectric Models of Normal and Diseased Human Trabecular Bones at Microwave Frequencies

eess.SP physics.med-phphysics.bio-ph ·2026-11-03 ·Bilal Amin, Amra Mehboob, Eoghan Dunne, Ana González-Suárez, Finn Krewer +3 more
publishedhighly cited similarity 0.50
Abstract · 12 pages, 9 figures, 8 tables. Published in IEEE Open Journal of Antennas and Propagation (open access, CC BY 4.0)

The dielectric properties of biological tissues are used to investigate the interaction of electromagnetic (EM) fields with the human body. These properties are integrated into EM numerical simulations, such as the finite difference time domain (FDTD) method, using dielectric models such as Cole-Cole and Debye models. These computational tools are employed to study the propagation of EM waves within the human body. This paper has developed the one-pole and two-pole Cole-Cole and Debye models for the dielectric properties of normal and diseased human trabecular bone tissue at microwave frequencies (0.5-8.5 GHz). The dielectric properties of normal trabecular and cortical bone were derived based on the literature, while those of diseased human trabecular bones (osteoporotic and osteoarthritis) were acquired from a previous study conducted by the authors, which characterised the properties within the 0.5-8.5 GHz frequency range. This study has employed a weighted least squares method to optimise the one-pole and two-pole dielectric models' parameters. The accuracy of the developed dielectric models is validated by comparing the simulated results with the experimental data already published by the authors. The comparative analysis of the models demonstrated that the one-pole Cole-Cole model achieved a better fit compared to the one-pole Debye model across all bone types. Additionally, the two-pole Cole-Cole model exhibited a better fit than the two-pole Debye model. The proposed models can be used in numerical simulations to investigate the interaction of EM fields with bone tissue and develop and optimise microwave bone health monitoring and treatment techniques.

0.65

Deep-Learning-Assisted Full Waveform Inversion for Attenuation Reconstruction in Ultrasound Computed Tomography

eess.SP physics.med-ph ·2026-11-17 ·Mingrui Liu, Michael L. Oelze
similarity 0.49
Abstract

Acoustic attenuation is more challenging to reconstruct and has received less attention than sound speed in ultrasound computed tomography using full-waveform inversion (FWI). In this study, a deep-learning (DL)-assisted FWI framework was proposed for attenuation reconstruction based on our previous work. Some numerical experiments were conducted to investigate the strategy and the effectiveness of using DL to help accelerate and improve the reconstruction quality of attenuation imaging in FWI. The results indicated that DL saved computational cost by 28% and improved attenuation reconstruction accuracy by 70% when combined with sufficiently accurate sound speed estimates. The result supports the potential of DL initialization to improve the computational efficiency and reconstruction quality of joint SOS and attenuation FWI.

0.29

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

eess.IV physics.app-ph ·2026-09-22 ·Gatien Clément, Alexandre Aubry, Cécile Brütt, Benoît Gérardin, Claire Prada
unusual similarity 0.48
Abstract · 13 pages, 14 figures

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

0.30