Deep-Learning-Assisted Full Waveform Inversion for Attenuation Reconstruction in Ultrasound Computed Tomography

Mingrui Liu, Michael L. Oelze

eess.SP physics.med-ph ·submitted 2026-11-17 22:01 UTC · v1

Abstract

Acoustic attenuation is more challenging to reconstruct and has received less attention than sound speed in ultrasound computed tomography using full-waveform inversion (FWI). In this study, a deep-learning (DL)-assisted FWI framework was proposed for attenuation reconstruction based on our previous work. Some numerical experiments were conducted to investigate the strategy and the effectiveness of using DL to help accelerate and improve the reconstruction quality of attenuation imaging in FWI. The results indicated that DL saved computational cost by 28% and improved attenuation reconstruction accuracy by 70% when combined with sufficiently accurate sound speed estimates. The result supports the potential of DL initialization to improve the computational efficiency and reconstruction quality of joint SOS and attenuation FWI.

Closest papers

Nearest neighbours by meaning across the whole index.

Simulation-to-Real First-Break Segmentation for Efficient Inversion in Musculoskeletal Ultrasound Tomography

eess.IV eess.SP ·2026-08-20 ·Yifei Sun, Yubing Li, Yannick Benezeth, Stéphanie Bricq, Yunrong Zhang +4 more
unusual similarity 0.65
Abstract

Full-waveform inversion (FWI) is a promising strategy for quantitative musculoskeletal ultrasound computed tomography (USCT), but bone-related scattering, attenuation, and signal degradation make it highly sensitive to the accuracy of the initial acoustic-property distributions and prone to cycle skipping. First-arrival traveltimes provide important kinematic information for initial-model construction, yet conventional trace-wise picking is unreliable when arrivals are weak, spatially heterogeneous, or buried in system noise. We propose a learning-assisted reconstruction pipeline that combines segmentation-based first-arrival extraction with hybrid full-waveform inversion (HFWI), which incorporates Rytov-approximation-based traveltime information together with waveform fitting during the early inversion stage. A lightweight 2D U-Net treats the first-arrival trajectory across receiver channels as a first-break segmentation target and exploits its spatial continuity rather than processing each trace independently. To address both limited manual annotations and the simulation-to-real gap, the network is pretrained on task-specific simulations augmented with real system-noise recordings, followed by stage-wise training with progressively increased signal degradation and decoder-only fine-tuning using limited weakly labeled experimental data. The method is evaluated on in vitro phantom, ex vivo bovine-limb, and in vivo human-thigh datasets. Compared with conventional STA/LTA picking, the proposed network yields more spatially coherent first-arrival trajectories, lower mean extraction errors, and processes a full-matrix-capture dataset within seconds. When integrated into HFWI, the extracted arrivals improve initial-model construction and lead to stable subsequent FWI reconstructions, including challenging cases with estimated local first-arrival SNRs below 3 dB.

0.28

Untrained CNN and coefficient-space regularization for joint reconstruction in photoacoustic tomography

cs.LG math.OC ·2026-10-16 ·Alfio Bozi, Anwesa Dey, Souvik Roy
similarity 0.59
Abstract

The joint reconstruction of the initial pressure and spatially varying sound speed in photoacoustic tomography from boundary measurements is considered. A regularized data-driven framework is proposed in which the unknown fields are represented in finite-dimensional wavelet spaces and fixed nonlinear features generated by an untrained convolutional neural network (CNN) are used to reconstruct the initial-pressure coefficients through Tikhonov-regularized least squares. A learned coefficient-space prior is subsequently used to infer the squared sound-speed coefficients. Numerical experiments demonstrate accurate reconstruction on held-out data and strong generalization to previously unseen phantom geometries. The frozen reconstruction map also remains stable under measurement noise not represented during training, with only minor changes in reconstruction accuracy for noise levels up to $10\%$. In comparison with the supervised trained-CNN approach considered in this work, the untrained representation yields substantially smaller reconstruction errors while requiring approximately one-sixth of the computational time. These results demonstrate that fixed random convolutional features combined with regularized coefficient-space learning provide an efficient and robust approach to joint reconstruction in photoacoustic tomography.

0.11

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.59
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

Initial condition recovery in nonlinear damped viscous photoacoustic tomography using a convolutional neural network-guided gradient-free optimization framework

cs.LG math.OC ·2026-10-01 ·Madhu Gupta, Anwesa Dey, Prapti Tala, Souvik Roy
similarity 0.58
Abstract

Photoacoustic tomography (PAT) is a hybrid imaging modality that combines high optical contrast with high ultrasonic resolution for biomedical imaging applications. In this work, we investigate the inverse problem of recovering the initial pressure distribution from boundary measurements in the presence of nonlinear acoustic propagation and viscous attenuation effects. To model these phenomena more accurately, we consider a nonlinear damped viscoelastic wave equation incorporating spatially varying sound speed, temporal attenuation, and nonlinear propagation mechanisms. We first establish the well-posedness of the corresponding forward problem using a Galerkin approximation combined with energy estimates and a fixed-point argument. For the inverse problem, we derive existence, uniqueness, and local uniqueness results under suitable assumptions through a harmonic extension reduction, spectral Laplace transform techniques, and observability estimates. To numerically reconstruct the initial pressure field, we develop a hybrid reconstruction framework that combines a convolutional neural network (CNN) with a gradient-free optimization strategy based on the sequential quadratic Hamiltonian (SQH) method derived from Pontryagin's maximum principle. The CNN is used to generate an informative initial guess, while the SQH framework enforces the governing PDE dynamics during the reconstruction process. Numerical experiments demonstrate that the proposed hybrid strategy significantly improves reconstruction quality, contrast, and robustness compared to standalone time-reversal and CNN-based approaches.

0.29

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.58
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.58
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29

Anatomical and Physical Supervision for CT-less PET Attenuation Correction: BIC-MAC 2026 Challenge

cs.CV ·2026-08-16 ·Petros Chatzitoulousis, George K. Matsopoulos
similarity 0.58
Abstract · 6 pages, 1 table. Technical report for the BIC-MAC 2026 Challenge

This report describes our submission to the Big Cross-Modal Attenuation Correction (BIC-MAC) 2026 Challenge for CT-less PET attenuation correction through multimodal pseudo-CT synthesis. We build upon a standard nnU-Net architecture and combine anatomical and physical supervision to improve both pseudo-CT quality and downstream PET reconstruction. Anatomical supervision is introduced through a frozen TotalSegmentator feature extractor, anatomy-guided structural constraints and patch sampling, while physical supervision is achieved using a differentiable attenuation correction factor projection loss based on multi-angle attenuation projections. Furthermore, the network is initialized with pretrained weights obtained from training on the SynthRAD Challenge MR-to-CT dataset. Minimal architectural modifications are applied, while performance improvements are pursued across the nnU-Net pipeline, including preprocessing, plans, and supervision design, among other components. Our final submission demonstrates the effectiveness of combining anatomical supervision, attenuation physics, and efficient nnU-Net scaling for CT-less PET attenuation correction.

0.07

Neural Surrogate Modeling of Ultrasonic Wave Propagation in Heterogeneous Media

cs.LG ·2026-10-09 ·Burla Nur Korkmaz, Petro Moilanen, Ari Salmi, Harsha Vardhan Tetali, Arto Klami
similarity 0.57
Abstract · Submitted to IEEE ICASSP 2027

Neural surrogates provide computationally efficient auto-regressive modeling of wave propagation, enabling e.g. fast inverse solutions. Despite recent progress, the current surrogates are not yet sufficient for the needs of ultrasonic sensing, characterized by high frequency and heterogeneous propagation media. We show how methods building on Fourier Neural Operators (FNO) fail to capture essential signal features, such as reflections, whereas U-Net -based methods learn the wave fields well but lack the ability to transfer information across different spatial scales. We then propose a new surrogate that captures the best of the two worlds, by integrating FNOs and local-integral resampling into a U-Net architecture. We show it can be trained on limited data, and that the predictions are robust to input noise and work across spatial scales.