CS Paper Radar

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

Can Deniz Bezek, Orcun Goksel

eess.IV physics.med-ph ·submitted 2026-08-23 16:15 UTC · v1
survey

Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.61
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.60
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

CrossRAFT: Cross-Domain Complex-Valued Feature Extraction for Ultrasound Motion Estimation

eess.SP ·2026-09-08 ·Yang Leng, Yuchen Tang, Kai-Hang Yiu, Yik-Chung Wu, Wei-Ning Lee
similarity 0.60
Abstract

Accurate multi-dimensional motion estimation is fundamental to broad biomedical ultrasound applications, primarily performed using real-valued radio-frequency (RF), analytic, and in-phase and quadrature (IQ) signals. Real-valued RF and analytic signals offer high subsample accuracy but are computationally intensive. Regardless of the signal domain used, traditional algorithms suffer from interframe decorrelation, resolution tradeoffs, and a lack of a carrier and low sampling in the lateral direction. Emerging deep learning (DL) models demonstrate improved performance and faster inference. However, existing architectures are real-valued and disrupt inherent phase coupling crucial for accurate motion estimation by treating complex components as independent channels. To address this, we propose CrossRAFT, an end-to-end trainable network designed for subsample motion estimation directly from complex-valued ultrasound signals. Built on the RAFT architecture, CrossRAFT features complex-valued encoders and a custom correlation module to explicitly extract and use phase information. We evaluated CrossRAFT across real RF, analytic, and IQ signal presentations on simulated phantoms, synthetic echocardiographic, and private in vivo echocardiographic datasets. Experimental results show that CrossRAFT estimates displacements accurately under complex tissue motion and in the challenging lateral direction. Compared to real RF-based RAFT, analytic-based CrossRAFT reduces vertical and horizontal displacement errors by 69% and 51% on the synthetic echocardiographic data, respectively. These findings demonstrate that leveraging phase information via complex-valued neural networks provides a powerful framework for ultrasound motion estimation, showing potential for clinical elastography and functional imaging.

0.30

Neural Surrogate Modeling of Ultrasonic Wave Propagation in Heterogeneous Media

cs.LG ·2026-10-09 ·Burla Nur Korkmaz, Petro Moilanen, Ari Salmi, Harsha Vardhan Tetali, Arto Klami
similarity 0.59
Abstract · Submitted to IEEE ICASSP 2027

Neural surrogates provide computationally efficient auto-regressive modeling of wave propagation, enabling e.g. fast inverse solutions. Despite recent progress, the current surrogates are not yet sufficient for the needs of ultrasonic sensing, characterized by high frequency and heterogeneous propagation media. We show how methods building on Fourier Neural Operators (FNO) fail to capture essential signal features, such as reflections, whereas U-Net -based methods learn the wave fields well but lack the ability to transfer information across different spatial scales. We then propose a new surrogate that captures the best of the two worlds, by integrating FNOs and local-integral resampling into a U-Net architecture. We show it can be trained on limited data, and that the predictions are robust to input noise and work across spatial scales.

0.16

Deep-Learning-Assisted Full Waveform Inversion for Attenuation Reconstruction in Ultrasound Computed Tomography

eess.SP physics.med-ph ·2026-11-17 ·Mingrui Liu, Michael L. Oelze
similarity 0.59
Abstract

Acoustic attenuation is more challenging to reconstruct and has received less attention than sound speed in ultrasound computed tomography using full-waveform inversion (FWI). In this study, a deep-learning (DL)-assisted FWI framework was proposed for attenuation reconstruction based on our previous work. Some numerical experiments were conducted to investigate the strategy and the effectiveness of using DL to help accelerate and improve the reconstruction quality of attenuation imaging in FWI. The results indicated that DL saved computational cost by 28% and improved attenuation reconstruction accuracy by 70% when combined with sufficiently accurate sound speed estimates. The result supports the potential of DL initialization to improve the computational efficiency and reconstruction quality of joint SOS and attenuation FWI.

0.29

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.58
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47

Physics-Guided Synthetic High-Frequency Ultrasound Generation for Skin Layer Segmentation

cs.LG cs.CV ·2026-09-11 ·Junkyung ju, Kyungho Yoon, Minwoo Shin
publishedcode/data similarity 0.58
Abstract · 12 pages, accepted at MICCAI DH4H Workshop 2026

High-frequency ultrasound (HFUS) enables noninvasive visualization of superficial skin structures, but automated skin-layer analysis is limited by the scarcity of densely annotated data. Existing real HFUS datasets commonly provide annotations for superficial targets such as the epidermis and subepidermal low-echogenic band (SLEB), while dense labels for deeper structures such as dermis, subcutaneous tissue, fascia, and muscle are rarely available. We propose a physics-guided synthetic HFUS generation framework for skin layer segmentation. The framework constructs multilayer acoustic skin phantoms, assigns layer dependent acoustic properties, and uses k-Wave simulation to generate paired synthetic HFUS images, dense layer masks, and simulation metadata. To evaluate whether the generated data provide transferable supervision, we use it for downstream segmentation pretraining and fine-tune the models on real Mendeley HFUS data. Synthetic pretraining followed by real fine-tuning achieved real-domain performance comparable to real-only training and improved mean Dice/IoU in three of four evaluated trainable architectures. These results suggest that physics-guided synthetic HFUS images contain transferable anatomical and textural cues for real-domain skin layer segmentation, although further reduction of the synthetic-real appearance gap is needed to enable greater gains. The code and data are available at: https://github.com/Finn-02/synthetic-hfus-skin-layer-segmentation.

0.50

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.57
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35