CS Paper Radar

CrossRAFT: Cross-Domain Complex-Valued Feature Extraction for Ultrasound Motion Estimation

Yang Leng, Yuchen Tang, Kai-Hang Yiu, Yik-Chung Wu, Wei-Ning Lee

eess.SP ·submitted 2026-09-08 12:02 UTC · v1

Abstract

Accurate multi-dimensional motion estimation is fundamental to broad biomedical ultrasound applications, primarily performed using real-valued radio-frequency (RF), analytic, and in-phase and quadrature (IQ) signals. Real-valued RF and analytic signals offer high subsample accuracy but are computationally intensive. Regardless of the signal domain used, traditional algorithms suffer from interframe decorrelation, resolution tradeoffs, and a lack of a carrier and low sampling in the lateral direction. Emerging deep learning (DL) models demonstrate improved performance and faster inference. However, existing architectures are real-valued and disrupt inherent phase coupling crucial for accurate motion estimation by treating complex components as independent channels. To address this, we propose CrossRAFT, an end-to-end trainable network designed for subsample motion estimation directly from complex-valued ultrasound signals. Built on the RAFT architecture, CrossRAFT features complex-valued encoders and a custom correlation module to explicitly extract and use phase information. We evaluated CrossRAFT across real RF, analytic, and IQ signal presentations on simulated phantoms, synthetic echocardiographic, and private in vivo echocardiographic datasets. Experimental results show that CrossRAFT estimates displacements accurately under complex tissue motion and in the challenging lateral direction. Compared to real RF-based RAFT, analytic-based CrossRAFT reduces vertical and horizontal displacement errors by 69% and 51% on the synthetic echocardiographic data, respectively. These findings demonstrate that leveraging phase information via complex-valued neural networks provides a powerful framework for ultrasound motion estimation, showing potential for clinical elastography and functional imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Guided Multi-Objective Deep Learning for Ultrasound RF Data Interpolation in Resource-Constrained Imaging

eess.IV cs.LG ·2026-09-23 ·Luoyuan Zhang, Yiyang You, Ananya Tandri, Yinan Feng, Hyunwoo Song +2 more
similarity 0.66
Abstract · Submitted to the Journal of Computational Design and Engineering

Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors $\times 2$ to $\times 13$, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.

0.18

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.62
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.61
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

CNet: A Complex-Valued Deep Learning Framework with Wirtinger Autodifferentiation and FFT--Hadamard Convolution

cs.LG cs.MSmath.OC ·2026-10-06 ·Marcel Crasmaru
similarity 0.60
Abstract

CNet is a C++/CUDA framework for deep complex-valued neural networks (CVNNs), trained by gradient descent with explicit Wirtinger (CR-calculus) derivatives. Complex models are underexplored yet natural where data is intrinsically complex -- RF/IQ, MRI k-space, radar/SAR, audio spectra -- and phase carries information real networks discard. CNet is physics-native: a network is a cascade of complex (often unitary) operations on an amplitude vector, and classification is a Born-rule measurement p_k = |z_k|^2 / ||z||^2 rather than a softmax over real logits. Every layer ships a CPU reference and a finite-difference-verified CUDA kernel; the static, batch-cloned computation graph captures cleanly into CUDA Graphs, outperforming eager and compiled torch.complex64 on an H100. We present three studies. (1) A fully complex causal language model, built on a new causal (triangular-masked) Fourier mixer with an O(N log N) Bluestein evaluation of the forward pass and its Wirtinger adjoint, matches a parameter-matched real causal FNet on character-level tiny-shakespeare in under half the steps. We introduce Born-rule attention, a content-based causal mixer whose weights are the quantum-measurement probabilities |<Q_k, K_j>|^2 -- to our knowledge the first classical, complex-valued attention to replace softmax with the squared-magnitude Born score; with rotary embeddings and per-token complex normalization it reaches 1.52 nats/char, matching softmax self-attention, and transfers unchanged to byte-level (1.31 nats/char) and sub-word WikiText-103. (2) On radio-modulation classification (RML2016.10a/RML22) we trace the pooled-power accuracy ceiling to discarded temporal structure and recover it with a learnable cyclostationary conjugate-lag operator. (3) A bottleneck analysis of the Fourier phase problem in coherent-diffraction imaging isolates where complex-valued networks still need new operators.

0.46

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.60
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-18 ·Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle, Chetan Shenoy, Mehmet Akçakaya
top venue similarity 0.59
Abstract · To appear in IEEE TBME

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

0.43

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.59
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29

EchoDiST: Self-distillation-based joint learning for diffusion-conditioned echocardiographic myocardial motion estimation

cs.CV ·2026-10-08 ·Feiyue Qi, Xingyue Wei, Jianwen Luo
similarity 0.58
Abstract · 19 pages, 14 figures

Motion estimation in echocardiography is essential for quantitative assessment of cardiac function and myocardial mechanics, but remains challenging due to image artifacts, limited image information, speckle decorrelation, and the scarcity of ground-truth displacement fields. Anatomy-guided approaches can provide structural information, yet often rely on expert-labeled myocardial segmentations. We propose EchoDiST, a framework for unsupervised echocardiographic myocardial motion estimation that integrates self-distillation-based joint learning with a diffusion-conditioned motion estimation network. Here, unsupervised motion estimation refers to learning without ground-truth displacement fields. The self-distillation strategy jointly optimizes anatomical segmentation and myocardial motion estimation under limited anatomical annotations. Diffusion-based conditioning is used during training with stochastic perturbations, while inference requires only a single deterministic forward pass without iterative reverse-diffusion sampling. EchoDiST was evaluated on three echocardiographic datasets, including two external test datasets under cross-view and cross-dataset settings. Compared with seven representative learning-based methods, EchoDiST consistently improved anatomical alignment, myocardial strain assessment, and motion-derived functional and cardiac-phase assessment. These gains were statistically significant across the evaluated tasks and datasets. Overall, EchoDiST provides an effective approach for reliable myocardial motion estimation under limited anatomical supervision and supports downstream quantitative assessment of cardiac function.

0.21