CS Paper Radar

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer, B. N. Frey, B. Federici, V. van Hal, L. D. van Harten, H. de Hoop, R. Lopata, B. Luijten, M. van Sambeek, V. van der Schaft, H. -M. Schwab, M. F. Azampour, N. Navab, R. Ali, A. Andrzejek, J. Baek, B. Boitnott, T. Brevett, H. Hashemi, D. Hyun, J. H. Park, A. V. Telichko, C. Thomas, L. Zhuang, Y. Aklilu, H. Arora, J. Barker, A. K. Mackanic, P. McDowall, L. McHugh, I. Pirozzi, S. Simon-Trench, A. M. Bronstein, O. Senouf, S. Vedula, D. Zadok, H. Rivaz, M. Sharifzadeh, S. Chen, G. P. Luke, S. Wang, Yujia Wu, J. Verde, R. Göbl, O. Zettinig, E. Boctor, Yixuan Wu, H. -M. Bae, M. -G. Kim, Y. -M. Kim, H. Lee, S. -H. Oh, P. Pinto, M. Berrada-Sounni, M. Carley, R. J. Fedewa, S. Gavin, N. Goldsmith, R. Kassayan, C. Low, R. Mehranfar, G. Bardoscia, M. Boccardo, A. Botter, M. Carbonaro, G. L. Cerone, E. Cesti, K. Meiburger, S. Seoni, F. Truscello, B. J. Raiteri, L. Caron, M. Gasse, N. Ghigo, O. Gulenko, A. Leconte, S. A. Lee, A. Malescot, E. Martineau, J. Porée, J. Provost, G. Ramos-Palacios, B. Rauby, R. L. Rungta, A. F. Sadikot, A. Wu, P. Xing, A. Chavignon, C. Ferlay, V. Hingot, M. Reberol, A. Waelbroeck, H. -S. Kwon, J. Bucholz, I. Guracar, R. Loftman, C. Williams, T. Grutman, T. Ilovitsh, T. A. Aleef, P. B. Chen, W. Chen, Y. Chen, M. Frew, M. Honarvar, Y. C. Lee, Z. Li, H. Moradi, R. Rohling, S. E. Salcudean, Z. Wu, Q. Zeng, P. C. Cattin, S. El Hadramy, N. Bottenus, A. S. Perez, S. Feng, Y. Feng, P. Jin, Y. Lin, O. Ostras, G. Pinton, F. Santibanez, M. Sode, B. Turkbey, H. Wang, B. J. Wood, L. Zhang, S. Luo, J. Wiskin, A. Austeng, Y. Karabiyik, S. P. Näsholm, O. M. H. Rindal, D. Bustamante, M. Mehrmohammadi, H. Raeis, A. Hameddine, G. Lajoinie, H. de Roo, M. Versluis, R. Zorgdrager, J. S. Au, A. J. Y. Chee, J. Cohen, T. Gu, J. Y. -H. Hsu, S. Ling, M. Mourtzakis, H. Nahas, P. de la Torre, D. Xiao, A. C. H. Yu, E. Zafiris, P. Jarosik, P. Karwat, Z. Klimonda, M. Lewandowski, B. Byram, C. Khan, Z. Marshall, Y. -C. Pan, S. Liu, T. Sultan, C. Hoerig, J. Mamou, D. Auerbach, Y. C. Eldar, A. Wegerhoff, G. S. Fischer, S. Katayose, X. Ma, R. Murakami, Y. Tang, R. Tsumura, Y. Wang, H. K. Zhang, M. Azizian, S. Huver, J. J. Dahl, R. J. G. van Sloun, W. Simson

eess.SP ·submitted 2026-10-09 14:00 UTC · v2
dataset

Abstract

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

Comment
Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.63
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29

Compression Hurts, Pooling Helps: Information Loss in Rayleigh-Scale Estimation from B-Mode Ultrasound

eess.IV cs.CVstat.AP ·2026-09-17 ·D. Hudson Smith, Ahmer Raza
similarity 0.63
Abstract · 20 pages, 7 figures

Clinical B-mode images are widely available as potential data sources for quantitative ultrasound (QUS) analysis for tissue characterization. However, standard clinical ultrasound devices apply unknown log-compression to RF envelope data before display and storage. Previous work has demonstrated estimation of the underlying RF envelope statistics in the presence of an unknown compression law. Using Fisher information analysis, we show that finite-offset log compression causes severe information loss when estimating the Rayleigh scale $σ$, which controls diffuse speckle. For a single image window, unknown compression raises the minimum achievable variance for unbiased estimation of $σ$ by a compression-independent factor of approximately 34.98. When $M$ equal-sized windows share the same unknown compression settings, the excess variance decays as $1/M$; even in the most favorable regime, reducing the variance inflation factor below 1.1 requires 340 windows. Our analysis treats the contrast parameter $a$ as unknown and the boundary offset $b$ as known; estimating $b$ experimentally shows even larger variance. We validate this theory using synthetic estimation experiments and demonstrate RF-scale recovery on real RF-envelope windows from the OASBUD dataset. Together, these results clarify the limitations of using routine B-mode images for QUS.

0.32

CrossRAFT: Cross-Domain Complex-Valued Feature Extraction for Ultrasound Motion Estimation

eess.SP ·2026-09-08 ·Yang Leng, Yuchen Tang, Kai-Hang Yiu, Yik-Chung Wu, Wei-Ning Lee
similarity 0.62
Abstract

Accurate multi-dimensional motion estimation is fundamental to broad biomedical ultrasound applications, primarily performed using real-valued radio-frequency (RF), analytic, and in-phase and quadrature (IQ) signals. Real-valued RF and analytic signals offer high subsample accuracy but are computationally intensive. Regardless of the signal domain used, traditional algorithms suffer from interframe decorrelation, resolution tradeoffs, and a lack of a carrier and low sampling in the lateral direction. Emerging deep learning (DL) models demonstrate improved performance and faster inference. However, existing architectures are real-valued and disrupt inherent phase coupling crucial for accurate motion estimation by treating complex components as independent channels. To address this, we propose CrossRAFT, an end-to-end trainable network designed for subsample motion estimation directly from complex-valued ultrasound signals. Built on the RAFT architecture, CrossRAFT features complex-valued encoders and a custom correlation module to explicitly extract and use phase information. We evaluated CrossRAFT across real RF, analytic, and IQ signal presentations on simulated phantoms, synthetic echocardiographic, and private in vivo echocardiographic datasets. Experimental results show that CrossRAFT estimates displacements accurately under complex tissue motion and in the challenging lateral direction. Compared to real RF-based RAFT, analytic-based CrossRAFT reduces vertical and horizontal displacement errors by 69% and 51% on the synthetic echocardiographic data, respectively. These findings demonstrate that leveraging phase information via complex-valued neural networks provides a powerful framework for ultrasound motion estimation, showing potential for clinical elastography and functional imaging.

0.30

Physics-Guided Multi-Objective Deep Learning for Ultrasound RF Data Interpolation in Resource-Constrained Imaging

eess.IV cs.LG ·2026-09-23 ·Luoyuan Zhang, Yiyang You, Ananya Tandri, Yinan Feng, Hyunwoo Song +2 more
similarity 0.61
Abstract · Submitted to the Journal of Computational Design and Engineering

Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors $\times 2$ to $\times 13$, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.

0.18

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.61
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

cs.CV ·2026-11-03 ·Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang +4 more
code/data similarity 0.61
Abstract

Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

0.21

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

cs.CV ·2026-09-15 ·Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran +1 more
code/data similarity 0.60
Abstract · Submitted to SPIE 2027

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

0.35

Simulation-to-Real First-Break Segmentation for Efficient Inversion in Musculoskeletal Ultrasound Tomography

eess.IV eess.SP ·2026-08-20 ·Yifei Sun, Yubing Li, Yannick Benezeth, Stéphanie Bricq, Yunrong Zhang +4 more
unusual similarity 0.60
Abstract

Full-waveform inversion (FWI) is a promising strategy for quantitative musculoskeletal ultrasound computed tomography (USCT), but bone-related scattering, attenuation, and signal degradation make it highly sensitive to the accuracy of the initial acoustic-property distributions and prone to cycle skipping. First-arrival traveltimes provide important kinematic information for initial-model construction, yet conventional trace-wise picking is unreliable when arrivals are weak, spatially heterogeneous, or buried in system noise. We propose a learning-assisted reconstruction pipeline that combines segmentation-based first-arrival extraction with hybrid full-waveform inversion (HFWI), which incorporates Rytov-approximation-based traveltime information together with waveform fitting during the early inversion stage. A lightweight 2D U-Net treats the first-arrival trajectory across receiver channels as a first-break segmentation target and exploits its spatial continuity rather than processing each trace independently. To address both limited manual annotations and the simulation-to-real gap, the network is pretrained on task-specific simulations augmented with real system-noise recordings, followed by stage-wise training with progressively increased signal degradation and decoder-only fine-tuning using limited weakly labeled experimental data. The method is evaluated on in vitro phantom, ex vivo bovine-limb, and in vivo human-thigh datasets. Compared with conventional STA/LTA picking, the proposed network yields more spatially coherent first-arrival trajectories, lower mean extraction errors, and processes a full-matrix-capture dataset within seconds. When integrated into HFWI, the extracted arrivals improve initial-model construction and lead to stable subsequent FWI reconstructions, including challenging cases with estimated local first-arrival SNRs below 3 dB.

0.28