CS Paper Radar

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran, Ilker Hacihaliloglu

cs.CV ·submitted 2026-09-15 02:48 UTC · v1
code/data

Abstract

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

Comment
Submitted to SPIE 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Wrong Organ, Right Physics: Transferring Echocardiography Pretraining to Lung Ultrasound for Tuberculosis Screening

eess.IV cs.CVcs.LG ·2026-10-02 ·Christiaan M. Geldenhuys, Joshua M. Jansen van Vüren, Véronique Suttels, Trevor Brokowski, Ablo P. Wachinou +4 more
published similarity 0.72
Abstract · 10 pages, 3 figures, 4 tables. Accepted at SATNAC 2026, Drakensberg, South Africa, 11-14 October 2026

Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries no such constraint, while sharing the same underlying ultrasound imaging physics, signal processing and B-mode appearance as LUS. We ask whether an encoder pretrained on that high-resource ultrasound domain carries representations that remain usable in the low-resource one. Only the encoder varies, across seventeen encoders spanning three architecture families. Among them, a latent-predictive video encoder pretrained on generic video (V-JEPA2-L) and its echocardiography counterpart (EchoJEPA-L) differ in pretraining corpus alone. The choice among these encoders does not resolve the classification, the whole family spanning 2.50 percentage points against a measurement resolution of 2.71. What moves the task instead is feature conditioning. Standardising the features between the encoder and the classifier improves all seventeen encoders by a mean of +1.23 percentage points at $p=1.5\times10^{-5}$. On the held-out test set every encoder selected on the development folds stands above the baseline system by up to +2.57 percentage points of area under the receiver operating characteristic curve (AUROC), and specificity at 90% sensitivity reaches 79.3% against 60.3%. The contrast specified in advance, EchoJEPA-L against V-JEPA2-L, measures -0.16 percentage points at $p=0.926$. We therefore find no evidence that shared ultrasonic physics alone makes echocardiography a more productive pretraining corpus than generic video, and any advantage, if present, is smaller than this cohort can resolve. The video encoders receive replicated still images, however, so whether this absence of an effect reflects the pretraining domain or a video encoder applied to static frames cannot be separated. The limiting factor is the labelled cohort rather than the encoder.

0.26

Benchmarking Self-Supervised 3D Medical Vision Foundation Models and Transferability Estimation

cs.CV cs.AI ·2026-10-13 ·Jiaqi Tang, Yu Wang, Yang Liu, Jing Tao, Fandong Zhang +5 more
benchmark similarity 0.65
Abstract

Self-supervised pretraining has expanded the pool of 3D medical foundation models, but published evaluations use different datasets, endpoints and fine-tuning protocols. Models also differ in architecture, pretraining objective and data, while downstream targets range from voxel-level masks to patient-level diagnoses and outcomes. As a result, published findings provide little directly comparable evidence for choosing a model for a new task. Direct comparison of adaptation performance requires fine-tuning candidates on labelled target data, at substantial computational cost. We benchmark 23 candidates across the same 14 segmentation, classification and regression tasks spanning multiple anatomies and modalities. No candidate ranked among the top three across all segmentation tasks or across all classification and regression tasks; a convolutional encoder could outperform a transformer trained with the same objective on one task but underperform it on another. We benchmark transferability estimators against the fine-tuned rankings and find that their agreement varies across dense segmentation, classification and regression. InsightRank uses task-appropriate frozen-feature statistics and architecture-aware pairwise comparisons to rank candidates before fine-tuning. Across the 23-model pool, mean Kendall tau-b was 0.431 for segmentation and 0.352 for classification and regression. The segmentation Top 3 contained a task winner on four of nine tasks; the image-level Top 3 contained none on the five tasks, despite better full-ranking agreement than the matched conventional estimators. A three-model shortlist reduced recorded extraction-plus-training job time by 85.8% across seven segmentation tasks. Together, the benchmark provides a common reference for model selection and InsightRank offers a lower-cost way to prioritize fine-tuning, with shortlist performance that differs by target type.

0.20

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

cs.CV cs.AI ·2026-09-24 ·Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli +1 more
similarity 0.64
Abstract · 80 pages including supplementary material, 28 figures, and 22 tables. Supplementary material is included

Long-tailed chest X-ray classification requires visual representations that capture both common abnormalities and subtle, infrequent findings. We propose Med-AR-8B and Med-AR-2B, two radiology-native autoregressive vision-language models pretrained with structured reports, abnormality-focused text, and region annotations. We evaluate the transfer of their visual encoders to multi-label classification against contrastive, self-supervised, and supervised pretrained encoders, including Med-CLIP, CheXFound, EVA-Base, ARK, and BioViL-T, using a common ML-Decoder classification head. To assess fine-grained recognition, we also construct LLM-expanded, report-derived label sets for MIMIC-CXR and CheXpert. Across PadChest, MIMIC-CXR, and CheXpert, Med-AR-8B outperforms Med-CLIP in mean AUROC and AUPRC for head, medium, and tail findings. On MIMIC-CXR, it increases tail-label mean AUPRC from 0.1033 to 0.1441. Med-AR-2B achieves the strongest discrimination results on PadChest. Across the broader encoder comparison, a Med-AR variant achieves the highest mean AUROC and AUPRC in every reported prevalence group on each public dataset. Both Med-AR variants also achieve lower excess area under the risk-coverage curve than Med-CLIP on all three public datasets, indicating improved selective-prediction performance under the evaluated protocol. Internal results are metric-dependent, with Med-CLIP retaining advantages in overall and tail AUPRC and in selective prediction. These findings establish Med-AR as a strong pretraining recipe for long-tailed chest X-ray classification on the evaluated public benchmarks and demonstrate the value of assessing discrimination and selective prediction together.

0.28

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.64
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Learning from Unlabeled Photographs for General Oral Image Analysis

cs.CV ·2026-11-03 ·Zhong-Shi Zhang, Zi-Li Yu, Xiao Xiao, Huan Liu, Gui-Song Xia +2 more
similarity 0.64
Abstract

Oral photographs contain rich clinical information and hold significant potential for artificial intelligence applications; however, most models are trained for individual tasks and rely on costly expert annotations. We hypothesized that self-supervised training on unlabeled oral photographs could produce transferable visual representations for heterogeneous vision tasks. To test this hypothesis, we developed DOVE (Dental Optical Visual Encoder) by domain-adaptive self-supervised pretraining on approximately 530,000 unlabeled oral photographs collected from publicly accessible sources. DOVE was benchmarked against 3 established baselines across 5 classification datasets and 4 segmentation datasets, covering both frozen backbone evaluation and end-to-end finetuning. DOVE achieved the strongest overall performance, ranking best in few-shot transfer and label efficiency on most benchmarks. Under the 20-shot frozen-backbone protocol, DOVE outperformed the second best DINOv3 by 4.37 percentage points in mean macro-F1 across classification datasets and by 4.49 percentage points in mean macro-Dice across segmentation tasks. Under end-to-end finetuning, DOVE achieved at least 80% of the strongest full-data baseline's performance across most evaluation datasets using only 10% of the labeled training data. Qualitative retrieval and feature analyses further indicated better organization of image-level and spatial representations. These findings support DOVE as a generalizable and label-efficient backbone for oral vision research.

0.17

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

eess.IV cs.AIcs.CV ·2026-08-22 ·Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
benchmark similarity 0.63
Abstract · 10 pages, 7 figures. Submitted to WACV 2027

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

0.33

Generative Active Learning for Label-Efficient Pan-Organ Ultrasound Diagnosis

cs.AI cs.HC ·2026-11-06 ·Yaofei Duan, Yuhao Huang, Yuan Gao, Ruixiang Qi, Tianyu Zhang +7 more
similarity 0.63
Abstract

Medical ultrasound (US) enables real-time, non-invasive diagnosis, yet building US-based AI systems is limited by data scarcity, costly expert annotation, and limited cross-center generalizability. Privacy constraints and instance-level reporting hinder the collection of diverse abnormal cases and frame-level labels, while repeated retraining for new centers increases computational cost. We introduce EvoDiff, a generative active learning framework that integrates diffusion modelling with information-theoretic objectives, evolutionary search, and curriculum-based sampling to select informative samples across heterogeneous US datasets. EvoDiff formulates sample selection as a generate-to-retrieve process, in which diffusion-based optimization in feature space guided by information gain produces synthetic probes, and only the real unlabeled samples retrieved by these probes are annotated and used for downstream training. Across six benchmarks covering fifteen datasets and 16,696 images, we evaluate EvoDiff on convolutional network and transformer-based foundation model. EvoDiff approaches fully supervised performance with substantially fewer labels, outperforms active learning baselines, and improves foundation model generalization under cross-domain external validation on unseen cohorts. A reader study with six radiologists indicates the potential to support clinical annotation workflows, with a model-based estimated 24% to 84% reduction in annotation workload at matched downstream performance.

0.24

Efficient Self-Supervised Adaptation of 3D Abdominal Vision-Language Model for Institution-Specific HCC Classification via Full Fine-Tuning and PEFT

cs.CV cs.LG ·2026-11-17 ·Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
published similarity 0.63
Abstract · 25 pages, 12 figures, 7 tables, including appendices. Corrected author revision of the MIDL 2026 paper. Revised preprocessing yields lower H…

Medical vision-language models (VLMs) capture cross-modal relationships between image and text, yet their adaptation to institution-specific clinical tasks remains underexplored. In this study, we fine-tuned a pretrained 3D medical VLM for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution with acquisition characteristics that differ from the model's original pretraining corpus. We compared two adaptation strategies: full fine-tuning and parameter-efficient fine-tuning (PEFT), motivated by the common use of PEFT to reduce computational cost and enable adaptation under limited-data constraints. Both approaches achieve strong downstream HCC classification performance despite the cross-institutional domain shift, with PEFT reaching an AUC of 0.79 and F1 of 0.70, and full fine-tuning achieving an AUC of 0.82 and F1 of 0.71. Although these results remain below the performance reported by supervised HCC classification approaches, our method achieves improvements over the pretrained model through CT-report contrastive learning without requiring lesion-level annotations or HCC classification labels as training targets. Full fine-tuning converges rapidly but overfits within a few epochs, whereas PEFT (ConvLoRA for the image encoder and LoRA for the text encoder) attains comparable performance while updating approximately 1% of the model parameters, although requiring more training steps. We also examine the role of contrastive temperature, observing that temperature initialization significantly affects classification performance. This study demonstrates that a 3D medical VLM can be efficiently adapted to institution-specific HCC classification using self-supervised CT-report contrastive learning, while highlighting the practical trade-offs between full fine-tuning and parameter-efficient fine-tuning.

0.37