CS Paper Radar

Wrong Organ, Right Physics: Transferring Echocardiography Pretraining to Lung Ultrasound for Tuberculosis Screening

Christiaan M. Geldenhuys, Joshua M. Jansen van Vüren, Véronique Suttels, Trevor Brokowski, Ablo P. Wachinou, Mary-Anne Hartley, Rensu P. Theart, Grant Theron, Thomas R. Niesler

eess.IV cs.CVcs.LG ·submitted 2026-10-02 13:33 UTC · v1
published

Abstract

Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries no such constraint, while sharing the same underlying ultrasound imaging physics, signal processing and B-mode appearance as LUS. We ask whether an encoder pretrained on that high-resource ultrasound domain carries representations that remain usable in the low-resource one. Only the encoder varies, across seventeen encoders spanning three architecture families. Among them, a latent-predictive video encoder pretrained on generic video (V-JEPA2-L) and its echocardiography counterpart (EchoJEPA-L) differ in pretraining corpus alone. The choice among these encoders does not resolve the classification, the whole family spanning 2.50 percentage points against a measurement resolution of 2.71. What moves the task instead is feature conditioning. Standardising the features between the encoder and the classifier improves all seventeen encoders by a mean of +1.23 percentage points at $p=1.5\times10^{-5}$. On the held-out test set every encoder selected on the development folds stands above the baseline system by up to +2.57 percentage points of area under the receiver operating characteristic curve (AUROC), and specificity at 90% sensitivity reaches 79.3% against 60.3%. The contrast specified in advance, EchoJEPA-L against V-JEPA2-L, measures -0.16 percentage points at $p=0.926$. We therefore find no evidence that shared ultrasonic physics alone makes echocardiography a more productive pretraining corpus than generic video, and any advantage, if present, is smaller than this cohort can resolve. The video encoders receive replicated still images, however, so whether this absence of an effect reflects the pretraining domain or a video encoder applied to static frames cannot be separated. The limiting factor is the labelled cohort rather than the encoder.

Comment
10 pages, 3 figures, 4 tables. Accepted at SATNAC 2026, Drakensberg, South Africa, 11-14 October 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

cs.CV ·2026-09-15 ·Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran +1 more
code/data similarity 0.72
Abstract · Submitted to SPIE 2027

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

0.35

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.61
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

Representation Risk in Pretrained Image Encoders

cs.CV econ.GN ·2026-09-28 ·Ardyn Nordstrom, Morgan Nordstrom, Vamuyan Sesay, Matthew D. Webb
benchmark similarity 0.61
Abstract

Applied researchers increasingly convert images into features with pretrained encoders, then use those features in a downstream prediction model. The encoder is often treated as an implementation detail. We show that it can instead be a consequential source of model uncertainty. We call this uncertainty representation risk: plausible pretrained encoders map the same images into different feature spaces and can yield sharply different out-of-sample conclusions from predictive performance. We compare ten modern and legacy frozen encoders across applications involving house prices, racehorse performance, breast-cancer histology, chest radiographs, continuous facial age, and rice disease. With common dimension control, heads, and group-safe splits, validation selects SigLIP 2 for houses, raising test $R^2$ from 0.396 for ResNet50 to 0.629, and DINOv2 for horses, raising $R^2$ from 0.029 to 0.105. No encoder is best in every task. Candidate procedures are constructed using training data and compared on a separate validation partition. The selected procedure reaches 0.658 for houses and 0.979 accuracy for pneumonia. Fixed-split gains are small for horses and rice, while repeated partitions reveal instability in horse feature union. Continuous age selects SigLIP 2 at 4.786 years MAE. The principal representation gaps persist with neural heads, similarly sized DINOv2 and ViT models, and limited adaptation. These results support a simple workflow: benchmark plausible representations, select on locked validation data, combine only when separate validation evidence justifies the additional cost, and report paired and split-level uncertainty. We implement this workflow in LOOKAGAIN-ML, the software package used to conduct the analyses in this paper.

0.31

Does Vendor Image Processing Matter? Learning Echocardiography Display Appearance from Native Beamspace Data

eess.IV cs.CV ·2026-10-30 ·Elias Stenhede, Arian Ranjbar
code/data similarity 0.60
Abstract

Most echocardiography datasets contain vendor-processed images, but processing is often undocumented and may affect model performance and robustness. To address this, we train a small convolutional neural network to reproduce General Electric display appearance from native beamspace brightness-mode ultrasound, using 8 406 recordings from 605 unique patients. The beamspace CNN reduces test mean absolute error by 43% over the optimal pointwise brightness map, outperforms an equivalent Cartesian CNN and runs in real time on a CPU. Across the EchoXFlow and CAMUS datasets, unfiltered training followed by filtered evaluation yields the lowest mean Dice for every class, suggesting filtering may be useful as augmentation when evaluation data are filtered or their processing is unknown. Code and pretrained weights: https://github.com/Ahus-AIM/EchoAppearance

0.44

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.60
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification

cs.SD cs.LG ·2026-11-18 ·Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana Yasmin
similarity 0.58
Abstract · 22 pages. Manuscript to be submitted to Biomedical Signal Processing and Control

Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.

0.17

Beyond Discrete Tokens: Preserving Numerical Continuity in Medical Vision-Language Models

cs.CV cs.AI ·2026-10-23 ·Dianye Huang, Jiamei Guo, Yue Zhou, Mingde Li, Yi Xiong +3 more
similarity 0.57
Abstract

Objective: To develop a unified vision-language model for prompt-conditioned quantitative ultrasound measurement that addresses the mismatch between continuous measurement targets and discrete token-based numerical prediction. Methods: This article presents HAD-VLM, a hybrid autoregressive-diffusion framework that combines autoregressive text generation with continuous measurement prediction within a shared backbone. Visual prompt tuning adapts the vision encoder to ultrasound images. A diffusion process predicts a five-component representation comprising caliper endpoint coordinates and measurement length. A post-processing strategy combining the proposed coordinate-length consistency mechanism with ensemble prediction is introduced to refine measurement estimates. We evaluate four echocardiographic measurement tasks on EchoNet-LVH, with additional assessments of medical question answering and X-ray vertebral measurement. Results: HAD-VLM achieves mean absolute errors of 1.36, 2.77, 3.05, and 1.16 mm for IVSd, LVIDd, LVIDs, and LVPWd, respectively, reducing errors by 21.4-37.6\% relative to the Vicuna-based autoregressive baseline. It also outperforms fine-tuned Qwen3-VL and direct MLP regression across all four tasks. Medical question answering performance is preserved on the evaluated dataset. For X-ray vertebral measurement, HAD-VLM reduces mean absolute error from 11.4 to 6.7 pixels. Conclusion: Integrating autoregressive language generation with diffusion-based continuous prediction improves quantitative medical image measurement while retaining prompt-conditioned task flexibility. Significance: HAD-VLM provides a unified approach to combining language interaction with anatomically grounded numerical prediction for quantitative medical image analysis.

0.32

Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations

cs.CV ·2026-11-13 ·Zahid Mansur, Kalpana Yadav, Deepak Mishra
similarity 0.56
Abstract

Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.

0.25