CS Paper Radar

Does Vendor Image Processing Matter? Learning Echocardiography Display Appearance from Native Beamspace Data

Elias Stenhede, Arian Ranjbar

eess.IV cs.CV ·submitted 2026-10-30 16:21 UTC · v1
code/data

Abstract

Most echocardiography datasets contain vendor-processed images, but processing is often undocumented and may affect model performance and robustness. To address this, we train a small convolutional neural network to reproduce General Electric display appearance from native beamspace brightness-mode ultrasound, using 8 406 recordings from 605 unique patients. The beamspace CNN reduces test mean absolute error by 43% over the optimal pointwise brightness map, outperforms an equivalent Cartesian CNN and runs in real time on a CPU. Across the EchoXFlow and CAMUS datasets, unfiltered training followed by filtered evaluation yields the lowest mean Dice for every class, suggesting filtering may be useful as augmentation when evaluation data are filtered or their processing is unknown. Code and pretrained weights: https://github.com/Ahus-AIM/EchoAppearance

Closest papers

Nearest neighbours by meaning across the whole index.

Wrong Organ, Right Physics: Transferring Echocardiography Pretraining to Lung Ultrasound for Tuberculosis Screening

eess.IV cs.CVcs.LG ·2026-10-02 ·Christiaan M. Geldenhuys, Joshua M. Jansen van Vüren, Véronique Suttels, Trevor Brokowski, Ablo P. Wachinou +4 more
published similarity 0.60
Abstract · 10 pages, 3 figures, 4 tables. Accepted at SATNAC 2026, Drakensberg, South Africa, 11-14 October 2026

Lung ultrasound (LUS) is attractive for tuberculosis (TB) screening at primary-care level, but labelled cohorts are small. Echocardiography carries no such constraint, while sharing the same underlying ultrasound imaging physics, signal processing and B-mode appearance as LUS. We ask whether an encoder pretrained on that high-resource ultrasound domain carries representations that remain usable in the low-resource one. Only the encoder varies, across seventeen encoders spanning three architecture families. Among them, a latent-predictive video encoder pretrained on generic video (V-JEPA2-L) and its echocardiography counterpart (EchoJEPA-L) differ in pretraining corpus alone. The choice among these encoders does not resolve the classification, the whole family spanning 2.50 percentage points against a measurement resolution of 2.71. What moves the task instead is feature conditioning. Standardising the features between the encoder and the classifier improves all seventeen encoders by a mean of +1.23 percentage points at $p=1.5\times10^{-5}$. On the held-out test set every encoder selected on the development folds stands above the baseline system by up to +2.57 percentage points of area under the receiver operating characteristic curve (AUROC), and specificity at 90% sensitivity reaches 79.3% against 60.3%. The contrast specified in advance, EchoJEPA-L against V-JEPA2-L, measures -0.16 percentage points at $p=0.926$. We therefore find no evidence that shared ultrasonic physics alone makes echocardiography a more productive pretraining corpus than generic video, and any advantage, if present, is smaller than this cohort can resolve. The video encoders receive replicated still images, however, so whether this absence of an effect reflects the pretraining domain or a video encoder applied to static frames cannot be separated. The limiting factor is the labelled cohort rather than the encoder.

0.26

Weight-Space Programming for Medical Imaging: Do We Still Need Training Data?

cs.CV ·2026-11-09 ·Maximilian Lindholz, Richard Ruppel, Annette Milnik, Sebastian Halskov, Semil Eminovic +9 more
code/data similarity 0.60
Abstract

Can a large language model (LLM) write the parameters of a medical image classifier from medical knowledge alone, without any training data? Such classifiers normally require labelled images, which are costly and often unavailable. We investigate this question through weight-space programming (WSP), in which an LLM writes or adapts the weights and biases of a neural network directly, without optimisation on training data. Claude Opus 5.5 and GPT-6 Astra each generate the parameters of a small LeNet-style CNN in a single reply, without tool use and without access to any image. We compare these networks against zero-shot MedSigLIP and against the same architecture trained on labels using the Adam optimiser, across 7 classification tasks in four modalities: chest X-ray, breast ultrasound and abdominal CT (all from MedMNIST), and pelvic MRI (SynthUterus). The LLM-written networks perform above chance on all six MedMNIST tasks, with a mean test AUC of 0.719 for Opus and 0.711 for Astra. Both models outperform MedSigLIP on 5 of 6 tasks while using more than 10,000 times fewer parameters. However, the same network trained with Adam on only 256 labelled images achieves a higher AUC on every MedMNIST task (mean AUC 0.828). On SynthUterus, Opus attains an AUC of 0.764, whereas Astra falls below chance (AUC 0.136) owing to a systematic error. These results show that LLMs can write functional medical classifiers, but that they do not yet replace training data. We release the protocol, logs and all generated weights at https://github.com/MaximilianLindholz/weight-space-programming-medical.

0.66

A Quantitative Evaluation Framework for Temporal Explainability in Echocardiographic Video Segmentation

cs.CV cs.LG ·2026-09-07 ·Jiyoo Noh, Jonathan H. Chan
similarity 0.58
Abstract · 15 pages, 5 figures

Deep learning has achieved state-of-the-art performance in echocardiographic video segmentation, with an increasing number of models incorporating temporal information. However, quantitative evaluation of temporal explainability remains largely unexplored. We propose a quantitative framework for evaluating Grad-CAM explanations using four complementary metrics measuring temporal consistency, saliency motion, anatomical overlap, and temporal overlap. Using EchoNet-Dynamic, we compare a baseline 2D U-Net with ConvLSTM U-Net models trained across multiple temporal strides. While segmentation performance remained comparable across all models, intermediate ConvLSTM explanations exhibited substantially lower saliency consistency and greater centroid motion than final prediction explanations. Temporal Bottleneck explanations were significantly more stable than Encoder Bottleneck explanations across all strides, while final ConvLSTM Decoder3 explanations were broadly comparable to those of the 2D U-Net. Importantly, conventional frame-wise explanation metrics cannot determine whether variation in intermediate explanations reflects meaningful temporal feature evolution or explanation instability. These findings establish a preliminary quantitative framework for temporal explainability and motivate temporal-aware XAI methods that explicitly account for evolving representations in medical video models.

0.23

Which Pretext Task Transfers? Self-Supervised Pretraining Objectives for Lung Ultrasound

cs.CV ·2026-09-15 ·Moein Heidari, Junbo Rao, Jai Choraria, Wenjin Chen, David J. Foran +1 more
code/data similarity 0.58
Abstract · Submitted to SPIE 2027

Self-supervised learning (SSL) can reduce the need for labelled medical images, but the choice of pretext objective remains unclear for lung ultrasound (LUS). Contrastive learning, masked reconstruction, and joint-embedding predictive architectures (JEPA) differ in the space in which their targets are defined, yet existing ultrasound studies compare them under different corpora, backbones, and evaluation protocols. We compare these three objective families using the same encoder backbone, pretraining corpus, optimisation schedule, and frozen-evaluation protocol. Encoders are pretrained on COVID-BLUeS LUS videos and evaluated with linear, $k$NN, and attentive probes at 5\%, 10\%, 50\%, and 100\% label budgets. Evaluation is performed on POCUS using patient-level five-fold cross-validation and on the independently acquired Mendeley-Uganda dataset, which is excluded from both pretraining and probe fitting. At the full label budget under linear probing, VideoMAE and V-JEPA achieve $66.5 \pm 13.1$ and $65.4 \pm 11.7$ balanced accuracy on POCUS, while MoCo achieves $42.1 \pm 1.2$. On Mendeley-Uganda, the ranking reverses: MoCo performs best at $62.7 \pm 1.0$, followed by VideoMAE at $53.8 \pm 2.8$, while V-JEPA falls near chance at $35.1 \pm 4.9$. These results show that POCUS probe accuracy alone does not identify the objective that transfers best across datasets. We also outline planned representation-level analyses to examine this reversal. Code is publicly available at https://github.com/moeinheidari7829/LUSVideoSSL.

0.35

Self-training for cross-centre coronary vessel segmentation in X-ray angiography using pre-contrast frame subtraction

cs.CV cs.AI ·2026-10-29 ·Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
similarity 0.57
Abstract · 7 pages, 2 figures, 3 tables

Deep learning models for coronary vessel segmentation in X-ray angiography often perform poorly on data from centres that were not represented in training. Apart from differences in equipment, the labels of the largest public dataset (ARCADE) are incomplete, as only the segments defined in the SYNTAX score are annotated. In this study, we evaluated whether self-training with pseudo-labels can improve performance on external data without additional manual annotation. Pseudo-labels were generated from two sources, namely the predictions of an nnU-Net model trained on ARCADE and a contrast map obtained by subtracting a pre-contrast frame from the same sequence. The nnU-Net predictions were extended along the contrast map, and pixels detected only in the subtraction image were assigned an ignore label and excluded from the loss. Six models were trained and tested on ARCADE and on two external datasets (XCAD and XACV). All first-round models initialised with the baseline predictions performed better than both the baseline and a control model fine-tuned for the same number of epochs. The model trained on the XCAD pool improved the macro-averaged Dice score by 2.7 points (95% CI 2.3-3.2), while the control decreased it by 0.6 points. A second round of self-training did not lead to further improvement. When an external model trained on 50 fully annotated images was used to generate the initial labels, the XCAD Dice score increased from 0.623 to 0.745 without any XCAD labels, although performance on XACV did not improve because large main vessels were missed. These results suggest that the benefit of self-training depends largely on the sensitivity of the model used to generate the initial pseudo-labels.

0.18

UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound

cs.CV cs.LG ·2026-09-23 ·Ashwath Radhachandran, Adam Tupper, Christian Gagné, William Speier
benchmark similarity 0.57
Abstract

Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.

0.05

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.57
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.57
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26