CS Paper Radar

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle, Chetan Shenoy, Mehmet Akçakaya

eess.IV cs.AIcs.CVcs.LGphysics.med-ph ·submitted 2026-08-18 17:31 UTC · v2
top venue

Abstract

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

Comment
To appear in IEEE TBME
DOI
10.1109/TBME.2026.3743233

Closest papers

Nearest neighbours by meaning across the whole index.

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.77
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

eess.IV cs.LGphysics.med-ph ·2026-11-19 ·Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack +2 more
top venuecode/data similarity 0.65
Abstract · 13 pages (incl. cover page), 6 figures, 2 tables. Accepted version of the article published in IEEE Transactions on Biomedical Engineering. …

Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.

0.49

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

eess.IV cs.CV ·2026-09-02 ·Chinmay Rao, Efe Ilıcak, Matthias J. P. van Osch, Mariya Doneva, Laurens Beljaards +3 more
similarity 0.65
Abstract

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.

0.28

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
similarity 0.64
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.64
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.64
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28

LGGS: Longitudinal MRI Reconstruction via Guided Group Sparsity

eess.IV cs.CV ·2026-10-15 ·Nikola Janjušević, Hersh Chandarana, Yao Wang, Li Feng
similarity 0.64
Abstract · 10 pages main, 8 figures main, 5 pages supplementary, 7 figures supplementary

Serial MRI is routinely performed in current clinical practice for disease surveillance and applications such as MR-guided radiotherapy. However, long MRI scan times increase costs and limit patient access, making accelerated image reconstruction of broad clinical importance. Previous scans of the same patient contain image information highly correlated with the current exam, yet existing reconstruction methods rarely exploit this information. Major challenges in the effective use of prior scans include inter-visit misregistration, pathological changes, and image phase variation. In this work, we propose Longitudinal Guided Group Sparsity (LGGS), an interpretable deep-learning framework for longitudinally informed MRI reconstruction derived from classical group sparsity. The prior scan is incorporated into the reconstruction regularizer through learned phase-invariant circulant attention that identifies corresponding features across exams. This formulation provides robustness to local in-plane and through-plane misregistration as well as inter-visit phase variation. Across acceleration rates, LGGS achieves state-of-the-art performance on longitudinal T1-weighted multi-coil brain MRI data, outperforming the evaluated unguided and longitudinally informed reconstruction methods, with substantially fewer learned parameters. We further evaluated the contributions of multiple guide slices and phase-invariant similarity and demonstrated that accelerated prior images can also serve as effective guides with minimal degradation in reconstruction quality.

0.21

Hankel Subspace Self-Supervised Learning for Parallel MRI Reconstruction

cs.CV ·2026-10-08 ·Mingyu Hu, Siquan Zhu, Xijun Zhong, Qiegen Liu
similarity 0.64
Abstract

Parallel magnetic resonance imaging reconstruction is an ill-posed inverse problem under undersampling. Multi-coil acquisition and Hankel lifting expose complementary repeated information: observations of the same anatomy across coils and repeated local k-space neighborhoods in overlapping windows. These dependencies guide recovery of missing k-space data. However, splitting lifted Hankel entries for self-supervision can place the original sample in both input and target, causing data leakage. We propose Hankel Subspace Self-Supervised Reconstruction (HSSRecon), a scan-specific reconstruction framework for parallel magnetic resonance imaging. HSSRecon partitions data by physical acquisition units before Hankel lifting and applies multiplicity normalization to repeated Hankel copies in overlapping windows. Rather than learning a mapping that directly predicts missing data, the network learns a compact complex-valued Hankel subspace operator. Reconstruction is performed over the original k-space variables using a conjugategradient solver with hard data consistency. This design separates structural learning in the Hankel domain from data consistency in the physical domain: the former exploits multi-coil and local Hankel correlations, while the latter solves over unacquired degrees of freedom. We provide theoretical analyses of physicalgroup splitting and multiplicity normalization, and establish positive definiteness, uniqueness, hard data consistency, and a finite-step conjugate-gradient error bound for the system. On fastMRI brain data with three contrasts and three sampling masks, HSSRecon achieves competitive peak signal-to-noise ratio, structural similarity, and normalized mean squared error across six aggregated conditions.

0.16