CS Paper Radar

LGGS: Longitudinal MRI Reconstruction via Guided Group Sparsity

Nikola Janjušević, Hersh Chandarana, Yao Wang, Li Feng

eess.IV cs.CV ·submitted 2026-10-15 21:02 UTC · v1

Abstract

Serial MRI is routinely performed in current clinical practice for disease surveillance and applications such as MR-guided radiotherapy. However, long MRI scan times increase costs and limit patient access, making accelerated image reconstruction of broad clinical importance. Previous scans of the same patient contain image information highly correlated with the current exam, yet existing reconstruction methods rarely exploit this information. Major challenges in the effective use of prior scans include inter-visit misregistration, pathological changes, and image phase variation. In this work, we propose Longitudinal Guided Group Sparsity (LGGS), an interpretable deep-learning framework for longitudinally informed MRI reconstruction derived from classical group sparsity. The prior scan is incorporated into the reconstruction regularizer through learned phase-invariant circulant attention that identifies corresponding features across exams. This formulation provides robustness to local in-plane and through-plane misregistration as well as inter-visit phase variation. Across acceleration rates, LGGS achieves state-of-the-art performance on longitudinal T1-weighted multi-coil brain MRI data, outperforming the evaluated unguided and longitudinally informed reconstruction methods, with substantially fewer learned parameters. We further evaluated the contributions of multiple guide slices and phase-invariant similarity and demonstrated that accelerated prior images can also serve as effective guides with minimal degradation in reconstruction quality.

Comment
10 pages main, 8 figures main, 5 pages supplementary, 7 figures supplementary

Closest papers

Nearest neighbours by meaning across the whole index.

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.65
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.65
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

eess.IV cs.CV ·2026-09-02 ·Chinmay Rao, Efe Ilıcak, Matthias J. P. van Osch, Mariya Doneva, Laurens Beljaards +3 more
similarity 0.64
Abstract

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.

0.28

Retrospective macromolecular pool fraction mapping from conventional clinical MRI: a physics-guided self-supervised deep learning framework

cs.CV physics.med-phcs.LG ·2026-10-27 ·Jelmer van Lune, Miha Fuderer, Oscar van der Heide, Matteo Maspero, Martin B. Schilder +3 more
similarity 0.64
Abstract · 38 pages, 24 figures

Macromolecular pool fraction (MPF) is a quantitative imaging biomarker sensitive to myelin integrity and other changes in tissue macromolecular content, but specialized acquisitions and reconstruction methods limit its use in large-scale studies. We present a physics-guided, self-supervised deep learning framework for retrospectively estimating MPF directly from conventional clinical brain MRI ($T_1$-weighted, $T_2$-weighted, and fluid-attenuated inversion recovery [FLAIR]) without paired quantitative reference scans. The framework embeds an analytical two-pool magnetization transfer signal model that related sequence-averaged radiofrequency transmit power to apparent longitudinal relaxation. To accommodate heterogeneous clinical protocols, the network conditions intermediate features on acquisition parameters via adaptive instance normalization. It was trained and evaluated on a multisite, multivendor, multiprotocol dataset of 7,705 MRI sessions (3 T). Across 1,237 test sessions, mean MPF was $0.182 \pm 0.007$ in white matter and $0.144 \pm 0.009$ in gray matter, with limited variation across vendor-by-protocol groups (between-group coefficient of variation: 2.65% and 5.63%, respectively). In 70 sessions with demyelinating-disease labels, MPF was 35.6% lower in segmented lesions than in normal-appearing white matter. MPF maps from two different clinical protocols acquired in a healthy volunteer showed a mean voxel-wise absolute percentage difference of 7.7% and a concordance correlation coefficient of $0.888$, indicating good cross-protocol consistency. These results suggest that magnetization transfer-informed self-supervised learning enables stable MPF mapping from conventional clinical MRI, providing a scalable approach to investigate demyelinating pathology in both existing imaging archives and prospectively acquired conventional clinical scans without dedicated qMT acquisitions.

0.28

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.64
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

Harnessing Magnitude-Only and Complex Measurements for Improved Dynamic MRI Reconstruction with Learned Priors

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-18 ·Mahdi Saberi, Yaşar Utku Alçalar, Merve Gülle, Chetan Shenoy, Mehmet Akçakaya
top venue similarity 0.64
Abstract · To appear in IEEE TBME

MRI reconstruction methods for undersampled k-space data naturally utilize complex-valued measurements. Parallel developments in sparse phase retrieval have shown that magnitude-only measurements may provide complementary information for signal recovery. However, their use in MRI reconstruction remains largely unexplored, due to lack of practical settings where informative magnitude measurements can be obtained without additional scan time. In this work, we investigate the use of auxiliary k-space magnitude information for accelerated steady-state dynamic MRI reconstruction, and demonstrate strong consistency of k-space magnitudes across time-frames. Building on this observation, we propose $\mathbb{C}+\text{Mag}$, a magnitude-informed physics-driven deep learning reconstruction method. The proposed method employs an ADMM-based unrolling framework with a novel magnitude-aware data-fidelity formulation, where quadratically smoothed optimization and momentum-based updates are introduced to address the non-differentiability and non-convexity of the magnitude constraints. Experiments on retrospectively undersampled cine MRI and phase-contrast flow MRI datasets, as well as prospectively undersampled real-time cine MRI acquisitions, demonstrate improved artifact suppression, sharper anatomical recovery, and better preservation of phase information compared to conventional PD-DL methods, which is further supported through blinded expert reader evaluations.

0.44

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.63
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.63
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12