CS Paper Radar

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann

eess.IV ·submitted 2026-09-11 15:29 UTC · v1

Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.73
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22

Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

eess.IV cs.LGphysics.med-ph ·2026-11-19 ·Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack +2 more
top venuecode/data similarity 0.68
Abstract · 13 pages (incl. cover page), 6 figures, 2 tables. Accepted version of the article published in IEEE Transactions on Biomedical Engineering. …

Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.

0.49

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.67
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.67
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.66
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.66
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Fast Self-Supervised Generative CT Denoising via Few-Step Sampling

cs.CV ·2026-11-19 ·Xingyi Yao, Zhengtao Ma, Zhennong Chen
similarity 0.66
Abstract · 30 pages, 4 figures, 2 tables. Xingyi Yao and Zhengtao Ma contributed equally to this work. Zhennong Chen is the corresponding author

Low-dose and thin-slice computed tomography (CT) images suffer from elevated noise that obscures anatomical detail, while clean references for supervised denoising are often unavailable. Although Noise2Noise permits self-supervised training from noisy pairs, direct regression tends to oversmooth fine structure. Averaging multiple independently generated samples mitigates this blur, though repeating multi-step diffusion sampling is costly. We introduce Noise2Noise with Improved Mean Flow (N2N-iMF) to accelerate this process via few-step sampling. N2N-iMF learns to generate one noisy image conditioned on its paired counterpart; at inference, independent outputs are sampled and averaged to suppress noise. We evaluated image quality and sampling efficiency on simulated thin-slice brain and low-dose abdominal CT across four sampling methods and averaging counts from 1 to 20, and validated the approach on real-world photon-counting CT (PCCT) brain scans. With ten samples per conditioning input and three network evaluations per sample, N2N-iMF achieved a mean absolute error of 2.60 HU on brain CT and 14.02 HU on abdominal CT, outperforming 50-evaluation denoising diffusion implicit model (DDIM) sampling (2.91 and 14.53 HU). On the same GPU, per-output generation time dropped from 7.29 to 0.43 s. Across eight PCCT cases, N2N-iMF reached a mean gray-white matter contrast-to-noise ratio of 1.341, versus 0.916 for Noise2Noise and 1.176 for DDIM. N2N-iMF accelerates self-supervised generative CT denoising without distillation while keeping the number of averaged outputs adjustable at inference.

0.24

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

cs.CV physics.med-ph ·2026-11-01 ·Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell +4 more
similarity 0.66
Abstract

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

0.21