CS Paper Radar

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian

eess.IV cs.CV ·submitted 2026-09-24 18:17 UTC · v2

Abstract

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

Comment
Made minor spelling and punctuation corrections

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-informed denoising method for image reconstruction in quantitative low-field MRI

eess.IV ·2026-09-11 ·Catarina Redshaw Kranich, Claudia Prieto, Christoph Kolbitsch, Felix Frederik Zimmermann
similarity 0.73
Abstract

Low-field magnetic resonance imaging (MRI) is becoming increasingly important for medical imaging because it can reduce healthcare costs while ensuring high diagnostic output. Nevertheless, quantitative imaging in low-field MRI faces challenges, such as low signal-to-noise ratio and long scan durations. Deep learning approaches have been proposed for image reconstruction to overcome these challenges. Still, deep learning often requires large high-quality training datasets which are usually not available for low-field applications. Here we propose a modular unrolled end-to-end deep learning method for the denoised reconstruction of quantitative parameter maps directly from k-space data for low-field MRI. It consists of three sub-networks that are iteratively applied. They are used for the regularization of the quantitative parameter estimation, as well as for the signal estimation that is based on simulated signal curves. It generalises well and can be applied to different field strengths and even different quantitative MR sequences without the need for new training data. We applied the presented method to noisy data of knees acquired at 0.55 T for the reconstruction of $T_2$-maps and compared it to other classical and deep learning methods. We also applied the proposed approach to $T_1$-mapping of knees at 72 mT and $T_2$-mapping of brains at 0.6 T. The presented approach outperforms the other reconstruction methods with a median difference below 4 ms to the ground truth $T_2$-map. Even though the network was trained with $T_2$-maps acquired at 0.55 T, it successfully denoised data acquired at different field strengths, sequences, and of different anatomies. As a result, the proposed network and its underlying method offer an efficient and flexible solution to denoise low-field MR data and make quantitative low-field MRI a feasible diagnostic tool for clinical applications.

0.13

Fast Self-Supervised Generative CT Denoising via Few-Step Sampling

cs.CV ·2026-11-19 ·Xingyi Yao, Zhengtao Ma, Zhennong Chen
similarity 0.67
Abstract · 30 pages, 4 figures, 2 tables. Xingyi Yao and Zhengtao Ma contributed equally to this work. Zhennong Chen is the corresponding author

Low-dose and thin-slice computed tomography (CT) images suffer from elevated noise that obscures anatomical detail, while clean references for supervised denoising are often unavailable. Although Noise2Noise permits self-supervised training from noisy pairs, direct regression tends to oversmooth fine structure. Averaging multiple independently generated samples mitigates this blur, though repeating multi-step diffusion sampling is costly. We introduce Noise2Noise with Improved Mean Flow (N2N-iMF) to accelerate this process via few-step sampling. N2N-iMF learns to generate one noisy image conditioned on its paired counterpart; at inference, independent outputs are sampled and averaged to suppress noise. We evaluated image quality and sampling efficiency on simulated thin-slice brain and low-dose abdominal CT across four sampling methods and averaging counts from 1 to 20, and validated the approach on real-world photon-counting CT (PCCT) brain scans. With ten samples per conditioning input and three network evaluations per sample, N2N-iMF achieved a mean absolute error of 2.60 HU on brain CT and 14.02 HU on abdominal CT, outperforming 50-evaluation denoising diffusion implicit model (DDIM) sampling (2.91 and 14.53 HU). On the same GPU, per-output generation time dropped from 7.29 to 0.43 s. Across eight PCCT cases, N2N-iMF reached a mean gray-white matter contrast-to-noise ratio of 1.341, versus 0.916 for Noise2Noise and 1.176 for DDIM. N2N-iMF accelerates self-supervised generative CT denoising without distillation while keeping the number of averaged outputs adjustable at inference.

0.24

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.66
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

Blind Video Denoising for Vocal Tract rtMRI using a Self-Supervised Ensemble

eess.IV cs.CV ·2026-10-29 ·Julian Andres Hernandez-Potes, Tomás Arias-Vergara, Daiqi Liu, Andreas Maier, Paula Andrea Perez-Toro
similarity 0.66
Abstract · 7 pages, 5 figures

Real-time magnetic resonance imaging of the vocal tract makes speech articulation directly observable, but the trade-off between temporal resolution and signal quality introduces substantial noise and obscures fine articulatory detail. Since clean references cannot be acquired for a moving vocal tract, supervised denoising approaches are not applicable in this setting. We propose a self-supervised denoising framework that combines spatiotemporal super-resolution learning with pseudo-supervision derived from a variance-stabilized non-local means filter. A dual-model fusion strategy balances noise suppression and preservation of high-frequency articulatory structure. Experiments on the USC-75 multi-speaker dataset under natural noise conditions show that the ensemble raises the signal-to-noise ratio by 11.9 dB on unseen subjects while attaining more high-frequency articulatory content in the frames. Among tuned implementations of anisotropic diffusion, block-matching filtering, non-local means and pre-smoothed non-local means, every configuration that achieves comparable noise suppression does so at the cost of high-frequency content or of structural fidelity. Under severe added Gaussian, Rayleigh and Rician noise, peak signal-to-noise ratio improves by 7.6 to 11.8 dB and structural similarity roughly triples. An ablation shows that the variance-stabilized pseudo-supervision is an essential element for denoising, and that the effect is attributable to the hard thresholding contained in the stabilization transform.

0.25

SIDUMN: Self-Supervised Image Denoising Under Symmetric Multiplicative Noise

cs.CV ·2026-11-17 ·Nyan Htet Naing, Gyeongha Hwang
similarity 0.66
Abstract · 10 pages, 4 figures, 2 tables

Self-supervised denoising is challenging when the corruption is multiplicative and signal-dependent. In this letter, we propose SIDUMN, a symmetric noisier framework for self-supervised denoising under mean-one symmetric multiplicative noise. Given noisy observations and the noise law, the method samples an independent synthetic noise factor from the same law and constructs two complementary noisier images by applying the factor and its reflection about one. The denoising network is trained to predict one noisier image from the other, and at inference the reconstructions of $K$ such antithetic pairs are averaged. We show that the population target of the training loss is the clean conditional mean minus a multiplicative cross-term. We further prove that, for any trained network, antithetic averaging never increases the expected squared error of a single noisier-input reconstruction. Numerical results validate the theoretical findings and the proposed method.

0.35

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.64
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.64
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.63
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36