CS Paper Radar

Physics-Guided Synthetic High-Frequency Ultrasound Generation for Skin Layer Segmentation

Junkyung ju, Kyungho Yoon, Minwoo Shin

cs.LG cs.CV ·submitted 2026-09-11 11:34 UTC · v1
publishedcode/data

Abstract

High-frequency ultrasound (HFUS) enables noninvasive visualization of superficial skin structures, but automated skin-layer analysis is limited by the scarcity of densely annotated data. Existing real HFUS datasets commonly provide annotations for superficial targets such as the epidermis and subepidermal low-echogenic band (SLEB), while dense labels for deeper structures such as dermis, subcutaneous tissue, fascia, and muscle are rarely available. We propose a physics-guided synthetic HFUS generation framework for skin layer segmentation. The framework constructs multilayer acoustic skin phantoms, assigns layer dependent acoustic properties, and uses k-Wave simulation to generate paired synthetic HFUS images, dense layer masks, and simulation metadata. To evaluate whether the generated data provide transferable supervision, we use it for downstream segmentation pretraining and fine-tune the models on real Mendeley HFUS data. Synthetic pretraining followed by real fine-tuning achieved real-domain performance comparable to real-only training and improved mean Dice/IoU in three of four evaluated trainable architectures. These results suggest that physics-guided synthetic HFUS images contain transferable anatomical and textural cues for real-domain skin layer segmentation, although further reduction of the synthetic-real appearance gap is needed to enable greater gains. The code and data are available at: https://github.com/Finn-02/synthetic-hfus-skin-layer-segmentation.

Comment
12 pages, accepted at MICCAI DH4H Workshop 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning

eess.IV cs.CV ·2026-08-31 ·Arash Tavangar, Larissa K. Chiu, Hamidreza Khodashenas, Gregory K. Berry, Amir Hooshiar
top venue similarity 0.61
Abstract

Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7\%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.

0.66

Dual Co-Train: Cross-Dataset Ultrasound Tongue Segmentation Under Extreme Data Scarcity

cs.CV cs.AI ·2026-08-18 ·Alisher Myrgyyassov, Zhen Song, Bruce Xiao Wang, Yu Sun, Min Ney Wong +2 more
similarity 0.60
Abstract

Ultrasound tongue contour segmentation remains challenging under cross-dataset domain shift, where limited annotations, probe variability, and acquisition noise often degrade model generalization. We present a source-free domain adaptation framework for robust ultrasound tongue segmentation built on a lightweight UltraUNet backbone. Starting from a checkpoint pretrained on only five labeled source images, simulating an underfitted constrained source model, the proposed method adapts to a fully-unlabeled target domain by iteratively refining pseudo-labels, filtering unreliable masks with a contour-based quality-control module, and generating target-style synthetic image-mask pairs through a segmentation-guided conditional GAN. The student model is then trained on a mixture of clean pseudo-labeled target images, noisy pseudo-labels with consistency regularization, and synthetic samples, enabling closed-loop adaptation without access to source data. We evaluate the method on 12 source-target transfer pairs across eight ultrasound tongue imaging datasets, and conduct source-size scaling experiments and ablation studies. Across all comparisons, the proposed framework improves segmentation overlap and contour accuracy over the baselines, including supervised ones. These results suggest that task-specific pseudo-label refinement and synthetic target-style augmentation can substantially improve source-free adaptation for ultrasound tongue imaging.

0.21

UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound

cs.CV cs.LG ·2026-09-23 ·Ashwath Radhachandran, Adam Tupper, Christian Gagné, William Speier
benchmark similarity 0.58
Abstract

Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.

0.05

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.58
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

LCM-UNet: Scale-Selective Mamba with Reparameterizable Multi-Basis Local Modeling for Lightweight Skin Lesion Segmentation

cs.CV ·2026-11-03 ·Md Shihabul Islam Shovo, Nishi Kanta Paul, Dip Kumar Saha, Kishor Morol
similarity 0.55
Abstract · 12 pages, 4 figures, 5 tables. Submitted to IEEE Journal of Biomedical and Health Informatics (JBHI)

Accurate lesion segmentation underpins automated dermoscopic analysis: masks enable measurements of asymmetry, border and size. Deployment in primary care or on mobile devices requires a compact network. Existing ultra-light Mamba U-Nets offer global context, but global-modeling cost depends on each Mamba block's resolution, while their local branches rely on a single square kernel. We introduce LCM-UNet, a 33,474-parameter U-shaped network that fuses every skip at its native resolution, restricts bidirectional Mamba to stages at one-sixteenth of the input resolution or coarser, and uses local convolutions at finer scales. A multi-basis reparameterizable adapter augments each local branch during training with dilated, horizontal and vertical depthwise kernels, then folds them into the host kernel before inference. Each skip connection also learns a stage-specific gain. Nine networks were retrained on the official ISIC 2017 and ISIC 2018 partitions under a harmonized protocol, with PH$^2$ reserved for external validation and ablations run on a development split. LCM-UNet achieved Dice scores of 88.62%, 89.73% and 90.46% on ISIC 2017, ISIC 2018 and PH$^2$, respectively, ranking first on both ISIC test sets and second on PH$^2$ among the compared models. In the native-resolution host, removing Mamba from the one-eighth-resolution decoder stage eliminated 63% of Mamba operations, corresponding to 5.3% of all operations, with a Dice change of $-0.03$ percentage points. The adapter improved Dice by 0.48 percentage points over a single host kernel without adding deployed parameters or operations. With latency so far measured only on a GPU, LCM-UNet is a candidate for resource-constrained deployment.

0.34

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.54
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.54
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.54
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47